nVent P2P2216G - ProLine G2 Full Mounting Subpanel, 2200x1600, Conductive
nVent

P2P2216G

UPC: 783510324483


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Full Mounting Subpanel, SKU P2P2216G, represents a significant advancement in enclosure interior management, designed for industrial environments where robust and efficient mounting solutions are paramount. Manufactured by nVent, a globally recognized leader in electrical enclosure solutions, this conductive subpanel is engineered to optimize space utilization and streamline the installation process for electrical and electronic components. Its substantial dimensions of 2200x1600mm provide ample surface area for mounting a wide array of equipment, from complex control systems and power distribution units to sensitive instrumentation. At the core of the ProLine G2 Subpanel's innovative design is the patent-pending EZ-Load Mounting System. This system is not merely an accessory but a fundamental component that redefines how subpanels are integrated into modular enclosures. The EZ-Load system offers unparalleled flexibility and safety, allowing for a variety of loading options that cater to different installation scenarios and personnel capabilities. This is particularly beneficial in confined spaces or when dealing with heavy equipment, as it minimizes the risk of injury and damage. Key features of the EZ-Load Mounting System include: * **Versatile Loading Options:** The integrated EZ-Load Glide Blocks enable vertical loading of the subpanel from the front, rear, or side of the enclosure. This adaptability ensures that installers can choose the most accessible and efficient method based on the specific site conditions and enclosure configuration. * **Horizontal Loading Capability:** A groundbreaking feature for subpanel installation, the EZ-Load system also supports horizontal loading. This method provides a more controlled and deliberate approach to positioning the subpanel, which is ideal for applications requiring precise alignment or when handling delicate or heavy components. * **Maximized Space Utilization:** By facilitating easier and more adaptable installation, the EZ-Load system indirectly contributes to better space management within the enclosure. This allows for more efficient layout of components, improved airflow, and easier access for maintenance. * **Enhanced Safety:** The controlled loading mechanisms significantly reduce the physical strain on installers and minimize the potential for accidental drops or impacts, thereby enhancing workplace safety. Constructed with conductive materials, this subpanel ensures proper electrical grounding for mounted equipment, a critical requirement for safety and performance in industrial settings. The robust construction of the ProLine G2 subpanel is typical of nVent's commitment to durability and reliability, ensuring it can withstand the demanding conditions found in manufacturing plants, data centers, utility substations, and other critical infrastructure applications. The UNSPSC code 39121334 categorizes this product under electrical enclosure components, highlighting its role in comprehensive electrical system builds. Choosing the nVent ProLine G2 Full Mounting Subpanel means investing in a solution that prioritizes efficiency, safety, and long-term operational integrity for your electrical enclosures.
  • Accommodates five loading options: vertical front, vertical side, vertical rear, horizontal front (frame over subpanel), horizontal rear (subpanel lowered into frame)
  • High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
  • Mounting subpanel is securely fastened at the top and bottom of the enclosure; subpanels less than 1200mm wide include four sets of EZ-Load Glide Blocks, four BV-M6 fasteners (block to frame) and four M12 Hex Bolts (subpanel to block); Subpanels 1200mm an
  • Subpanels greater than 1000mm wide are 11 gauge (3.0 mm) mild steel, while subpanels 100mm or narrower are 12 gauge (2.5mm); conductive or white painted finish available
  • Subpanels can be mounted at any depth in 25-mm increments (front to back); accommodates back-to-back and fully recessed rear positions
  • Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames
  • Optional panel support bracket available for applications requiring more support in the center of the subpanel; this is required if the enclosure will be tipped in transit or if the panel is not located at the bottom of the enclosure on the glide blocks
  • Panels can be installed in the rearmost position, or positioned so joined enclosures provide a continuous mounting surface without requiring joining panels
  • High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
  • Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames

Specifications

Application
Controls and Drives; Power Distribution
Color
Unpainted
Finish
Galvanized
Fits Frame
2200x1600 mm
Material
Mild Steel
Product Family
ProLine
Thickness
3.04 mm
Thickness
11 ga
Type
Galvanized
Weight
160 lb
Package Dimensions (L x W x H)
84 IN x 46.5 IN x 2.5 IN
Package Dimensions (L x W x H)
213.36 cm x 118.11 cm x 6.35 cm
Package Weight (Imperial)
160.000 L
Package Weight (Metric)
72.576 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2K18108E Controller

This guide provides step-by-step instructions for installing and configuring the P2K18108E Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K18108E controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and properly insulated.

  3. Configure the controller settings

    Power on the controller and use the interface to navigate to the settings menu. Adjust the parameters as required for your application and save the configuration.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Use a multimeter to verify output signals.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.