nVent P2P184G - ProLine G2 Full Mounting Subpanel, 1800x400, Conductive
nVent

P2P184G

UPC: 783510324186


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Full Mounting Subpanel, SKU P2P184G, represents a significant advancement in enclosure interior management, offering unparalleled ease of installation and enhanced space utilization. Manufactured by nVent, a globally recognized leader in electrical enclosure solutions, this conductive subpanel is designed to integrate seamlessly into modular enclosure systems, providing a robust and reliable platform for mounting electrical and electronic components. The ProLine G2 Subpanel is a cornerstone of the patent-pending EZ-Load Mounting System. This innovative system redefines how subpanels are installed, prioritizing speed, safety, and flexibility. The EZ-Load Glide Blocks are engineered to offer multiple loading options, allowing for vertical installation from the front, rear, or side of the enclosure. This adaptability is crucial in environments where space is at a premium or access is restricted. Furthermore, the EZ-Load system introduces a horizontal loading capability, a novel approach that provides a more controlled and deliberate method for positioning the subpanel within modular enclosures. This feature minimizes the risk of damage to components and ensures precise alignment, streamlining the assembly process for technicians. Constructed with conductive materials, this subpanel ensures proper grounding and electrical continuity, a critical requirement for safety and performance in industrial electrical installations. The generous dimensions of 1800x400mm provide ample surface area for a wide array of equipment, including power distribution units, control systems, automation hardware, and communication devices. Its robust construction is built to withstand the demanding conditions typically found in industrial settings, such as manufacturing plants, data centers, and utility facilities. Key benefits of the nVent ProLine G2 Subpanel include: * **Enhanced Installation Efficiency:** The EZ-Load system drastically reduces installation time and complexity. * **Maximized Space Utilization:** The intelligent design allows for more efficient component layout within the enclosure. * **Increased Safety:** Multiple loading options and controlled installation minimize physical strain and risk of accidents. * **Versatile Mounting Options:** Front, rear, side, and horizontal loading cater to diverse installation scenarios. * **Reliable Performance:** Conductive construction ensures essential electrical grounding and continuity. This subpanel is an ideal solution for applications requiring high-density component mounting and efficient thermal management. Its compatibility with nVent's ProLine G2 enclosure series ensures a cohesive and integrated solution for your electrical infrastructure needs. Professionals in the industrial automation, telecommunications, and power distribution sectors will find the ProLine G2 Subpanel to be an indispensable component for building secure, efficient, and maintainable electrical systems. The commitment to quality and innovation from nVent ensures that this subpanel will deliver long-term value and operational excellence.
  • Accommodates five loading options: vertical front, vertical side, vertical rear, horizontal front (frame over subpanel), horizontal rear (subpanel lowered into frame)
  • High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
  • Mounting subpanel is securely fastened at the top and bottom of the enclosure; subpanels less than 1200mm wide include four sets of EZ-Load Glide Blocks, four BV-M6 fasteners (block to frame) and four M12 Hex Bolts (subpanel to block); Subpanels 1200mm an
  • Subpanels greater than 1000mm wide are 11 gauge (3.0 mm) mild steel, while subpanels 100mm or narrower are 12 gauge (2.5mm); conductive or white painted finish available
  • Subpanels can be mounted at any depth in 25-mm increments (front to back); accommodates back-to-back and fully recessed rear positions
  • Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames
  • Optional panel support bracket available for applications requiring more support in the center of the subpanel; this is required if the enclosure will be tipped in transit or if the panel is not located at the bottom of the enclosure on the glide blocks
  • Panels can be installed in the rearmost position, or positioned so joined enclosures provide a continuous mounting surface without requiring joining panels
  • High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
  • Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames

Specifications

Application
Power Distribution; Controls and Drives
Color
Unpainted
Finish
Galvanized
Material
Mild Steel
Product Family
ProLine
Thickness
12 ga
Thickness
2.66 mm
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
54 lb
Package Dimensions (L x W x H)
2 IN x 2 IN x 2 IN
Package Dimensions (L x W x H)
5.08 cm x 5.08 cm x 5.08 cm
Package Weight (Imperial)
2.000 L
Package Weight (Metric)
0.907 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2KDR18186 Controller

This guide provides step-by-step instructions for installing and configuring the P2KDR18186 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2KDR18186 controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage is within the specified range before powering on the device.

  4. Power on the controller

    Turn on the power supply to the controller and observe the status indicators to ensure the device is functioning correctly.

  5. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters as per your application requirements.

  6. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate operation of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.