nVent P2KXD2045 - ProLine G2 Sequestr External Disconnect Type 12, 2000x400x500, Lt Gray, Steel
nVent

P2KXD2045

UPC: 783510368012


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

Enhance industrial safety with the nVent ProLine G2 Sequestr External Disconnect (SKU: P2KXD2045). This Type 12 enclosure, constructed from 16-gauge steel, is designed to mitigate arc flash hazards by isolating incoming power externally. Technicians can safely perform maintenance on interior enclosure components with reduced risk of electrical incidents. The ProLine G2 Sequestr integrates a disconnect switch and fuse block or circuit breaker within its dedicated external enclosure, featuring terminal connections for pass-through power to the main control enclosure. This ensures the primary power source is de-energized before internal access is granted. Built on a full-height ProLine G2 frame, it offers seamless compatibility with other ProLine G2 enclosures. Key specifications include UL 508A Listed, Type 12 rating, CSA File Number 42186, and IP55 rating (IEC 60529). It features a hinged disconnect mullion for unobstructed access, an interlocking mechanism for safety, and a preferred disconnect cutout accommodating up to 200A switches. The enclosure measures 2000x400x500mm and is finished in ANSI 61 gray polyester powder paint. Ideal for manufacturing plants and processing facilities requiring enhanced safety protocols and arc flash mitigation.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Standardized on 400mm (15.7-in.) solution width
  • Disconnect provision on mullion door will accept the following types of flange-mounted disconnect devices: Allen-Bradley - Bulletin 1494V disconnect switches and circuit breakers with flange-mounted, variable-depth operating mechanisms; ABB Controls (Disc
  • Mullion door with standard disconnect cut-out is hinged on the left, with adjacent door hinged on the right; mullion door is opened via two quarter-turn cams; both mullion and adjacent doors hinge 140-degrees
  • Door on right-hand side of Sequestr unit is considered a secondary door, with interlocking components included
  • Interlock components supplied to control primary door of adjacent enclosure to the left (enclosure sold separately), along with secondary door of Sequestr solution
  • Interlock must be defeated to unlock door(s); the primary door must be in the open position to open any secondary door in the system
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the right-hand door
  • Should be bayed to a ProLine G2 Industrial Package, or similar configuration, however a Sequestr Barrier Panel (not included) must be used to maintain disconnect integrity

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Finish
Powder Coated
Height
78.82
Height
2,002
Insulation
No
Material
Mild Steel
Material
Steel
Max Subpanel Size
75 x 12.9 in
Max Subpanel Size
1906 x 328 mm
NEMA Rating
12
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2 Sequestr
Size
78.82 x 16.05 x 19.88
Size
2000x400x500
Thickness
1.52 mm
Thickness
16 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
137.07 lb
Width
16.05
Width
408
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom solution.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames, covers, and doors.

How do I install the internal components?

Internal components can be mounted using grid straps and various mounting brackets provided.

How to Install the P2KXD2045 Controller

This guide provides step-by-step instructions for installing and configuring the P2KXD2045 Controller, ensuring proper setup and operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2KXD2045 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and insulated to prevent short circuits.

  3. Configure the controller settings

    Power on the controller and access the configuration menu using the provided interface. Set the necessary parameters according to your application requirements and save the settings.

  4. Verify the installation

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct power supply. Confirm that all connections are secure and functioning properly.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates within specified parameters. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.