nVent P2KXD1845 - ProLine G2 Sequestr External Disconnect Type 12, 1800x400x500, Lt Gray, Steel
nVent

P2KXD1845

UPC: 783510367978


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

Enhance safety and operational efficiency in industrial environments with the nVent ProLine G2 Sequestr External Disconnect (SKU: P2KXD1845). This robust Type 12 enclosure is engineered to significantly mitigate arc flash hazards when performing maintenance or accessing interior components of main electrical enclosures. By isolating incoming power externally, it provides a critical layer of protection for personnel, allowing work to be conducted on internal systems without the risk of live electrical discharge. The ProLine G2 Sequestr features a high-quality steel construction finished in a light gray, ensuring durability and resistance to harsh industrial conditions. Its substantial dimensions of 1800x400x500mm offer ample space for the integrated disconnect switch and fuse block or circuit breaker, facilitating straightforward installation and connection. This advanced disconnect solution functions analogously to nVent HOFFMAN’s renowned Sequestr product but is built upon the full-height ProLine G2 frame. This design ensures seamless integration with existing ProLine G2 infrastructure, offering a unified and aesthetically consistent electrical enclosure system. The external mounting of the disconnect switch and fuse block/circuit breaker streamlines access for routine operations and emergency shutdowns, while terminal connections are strategically placed to efficiently route power to the main enclosure. Key benefits and features include: * **Arc Flash Mitigation:** Significantly reduces arc flash risk by isolating incoming power before it reaches the main enclosure. * **Enhanced Safety:** Protects personnel during maintenance and servicing of internal electrical components. * **Robust Construction:** Made from durable steel with a Type 12 rating for protection against dust and water ingress. * **Seamless Integration:** Designed to fit perfectly with nVent HOFFMAN ProLine G2 enclosure systems. * **Convenient Access:** External mounting of disconnect switch and fuse block/circuit breaker for ease of use. * **Versatile Configuration:** Accommodates both fuse blocks and circuit breakers for flexible power distribution. The nVent ProLine G2 Sequestr is an indispensable component for any facility prioritizing electrical safety and operational continuity. Its application spans various industries, including manufacturing, utilities, data centers, and any sector where high-power electrical systems require safe and reliable isolation. Investing in this external disconnect solution from nVent HOFFMAN, a trusted leader in electrical enclosure solutions, demonstrates a commitment to best practices in industrial safety and equipment longevity. The UNSPSC code for this product is 39121334, and it is proudly manufactured in the USA.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Standardized on 400mm (15.7-in.) solution width
  • Disconnect provision on mullion door will accept the following types of flange-mounted disconnect devices: Allen-Bradley - Bulletin 1494V disconnect switches and circuit breakers with flange-mounted, variable-depth operating mechanisms; ABB Controls (Disc
  • Mullion door with standard disconnect cut-out is hinged on the left, with adjacent door hinged on the right; mullion door is opened via two quarter-turn cams; both mullion and adjacent doors hinge 140-degrees
  • Door on right-hand side of Sequestr unit is considered a secondary door, with interlocking components included
  • Interlock components supplied to control primary door of adjacent enclosure to the left (enclosure sold separately), along with secondary door of Sequestr solution
  • Interlock must be defeated to unlock door(s); the primary door must be in the open position to open any secondary door in the system
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the right-hand door
  • Should be bayed to a ProLine G2 Industrial Package, or similar configuration, however a Sequestr Barrier Panel (not included) must be used to maintain disconnect integrity

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Finish
Powder Coated
Height
70.94
Height
1,802
Insulation
No
Ip Rating
Type 12
Material
Mild Steel
Material
Steel
Max Subpanel Size
67.2 x 12.9 in
Max Subpanel Size
1706 x 328 mm
Nema Rating
Type 12
NEMA Rating
12
Product Family
ProLine
Series
ProLine G2 Sequestr
Size
70.94 x 16.05 x 19.88
Size
1800x400x500
Size
1800x400x500 mm
Thickness
1.52 mm
Thickness
16 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
126.81 lb
Width
16.05
Width
408
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom solution.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames, covers, and doors.

How do I install the internal components?

Internal components can be mounted using grid straps and various mounting brackets provided.

How to Install the P2KXD1845 Controller

This guide provides step-by-step instructions for installing and configuring the P2KXD1845 Controller, ensuring proper setup and functionality.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2KXD1845 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely fastened.

  2. Connect the power supply

    Use wire connectors to connect the power supply wires to the controller's power terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Configure the controller settings

    Power on the controller and use the configuration software to set the desired parameters. Follow the on-screen instructions to complete the setup.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure outlined in the user manual. Use a multimeter to verify output signals are within specified ranges.

  5. Test the installation

    After calibration, run a test to ensure the controller operates as expected. Monitor the system for any irregularities and make adjustments as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.