nVent P2KOD20165 - ProLine G2 Industrial Packages Type 12 2Dr, 2000x1600x500, Lt Gray, Steel
nVent

P2KOD20165

UPC: 783510323011


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

Introducing the nVent ProLine G2 Industrial Package Type 12 (2-door) enclosure, engineered for robust protection and streamlined deployment in demanding industrial environments. Part number P2KOD20165 delivers a comprehensive, ready-to-install solution that eliminates the complexity of sourcing individual components. This full-featured enclosure combines a heavy-duty steel frame, solid doors with handle and key lock, solid top and rear cover, full mounting subpanel, gland plate, and four integrated lifting eyes—all included under a single SKU for maximum convenience and cost efficiency. Designed to meet NEMA Type 12 standards, the ProLine G2 Industrial Package provides superior protection against dust, dirt, and non-corrosive liquids, making it ideal for use in manufacturing plants, food and beverage processing facilities, pharmaceutical labs, and water treatment plants. Its light gray finish offers high visibility and resistance to surface wear, while the steel construction ensures long-term durability and structural integrity even under heavy loads or in high-vibration settings. The 2000 x 1600 x 500 mm dimensions offer substantial internal space for housing large control panels, PLCs, motor starters, or other sensitive electrical and automation equipment. The two-door design enables easy access for installation, maintenance, and troubleshooting, while the included mounting subpanel simplifies internal component organization and reduces installation time. Side covers (sold separately) are available to support baying or joining applications, allowing for scalable, modular system expansion. nVent, a global leader in thermal management and electrical protection solutions, brings decades of engineering excellence to the ProLine G2 series. Known for innovation and reliability, nVent products are trusted by engineers and facility managers worldwide to protect critical infrastructure in harsh industrial conditions. With Type 12 compliance, this enclosure is suitable for indoor use where protection from environmental contaminants is essential, and where operator safety and equipment longevity are priorities. Choose the nVent ProLine G2 Type 12 Industrial Package for a complete, compliant, and cost-effective enclosure solution. Whether upgrading existing systems or outfitting a new facility, this pre-engineered package reduces procurement complexity and accelerates project timelines—without compromising on quality or performance.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Door Quantity
2
Finish
Powder Coated
Height
78.82
Height
2,002
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
42
Max Subpanel Size
75.0 x 60.2 in
Max Subpanel Size
1906 x 1528 mm
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
2000x1600x500 mm
Type
Mild Steel Modular Industrial Enclosures
Weight
663 lb
Width
63.29
Width
1,608
Package Dimensions (L x W x H)
69 IN x 26 IN x 87 IN
Package Dimensions (L x W x H)
175.26 cm x 66.04 cm x 220.98 cm
Package Weight (Imperial)
663.000 L
Package Weight (Metric)
300.737 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom solution.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames, covers, and doors.

How do I install the internal components?

Internal components can be mounted using grid straps and various mounting brackets provided.

How to Install the P2K1846 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1846 Controller, ensuring proper setup and functionality.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1846 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Verify the connections are tight and secure.

  3. Configure the controller settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements and save the settings.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual. Use a multimeter to verify output signals and adjust settings as necessary for accurate performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.