nVent P2KOD1885E - ProLine G2 Industrial Packages Type 12 E-Cnfg 2Dr, 1800x800x500, Lt Gray, Steel
nVent

P2KOD1885E

UPC: 783510322762


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Industrial Package (SKU: P2KOD1885E) delivers a complete, ready-to-install enclosure solution designed for demanding industrial environments. This Type 12-rated enclosure combines robust construction with comprehensive component integration, eliminating the need for separate sourcing of critical parts. Engineered by nVent—an industry leader in thermal management and electrical protection solutions—the ProLine G2 package includes a heavy-duty steel frame, solid doors with handle and key lock, solid top and rear covers, a full mounting subpanel, gland plate, and four lifting eyes for safe and efficient handling. Side covers are available separately to support baying and joining applications, offering flexibility for system expansion and modular configurations. Type 12 enclosures like the ProLine G2 are essential for protecting electrical and electronic components in industrial settings where dust, dirt, and non-corrosive liquids pose contamination risks. Typical applications span across manufacturing plants, food and beverage processing facilities, pharmaceutical production, automotive assembly lines, and wastewater treatment plants. The 1800x800x500mm dimensions provide ample internal space for housing control panels, PLCs, variable frequency drives (VFDs), relays, and other critical automation equipment. The light gray powder-coated finish not only enhances corrosion resistance but also improves visibility in low-light environments, supporting safer maintenance and inspection workflows. Professionals choose nVent ProLine G2 packages for their reliability, compliance, and ease of installation. The integrated mounting subpanel simplifies internal component organization, while the gland plate accommodates cable entry without compromising protection ratings. The solid doors with key lock ensure secure access control, reducing the risk of unauthorized tampering or accidental exposure to live components. Installation is streamlined thanks to pre-drilled mounting holes and a design optimized for NEMA and IEC compliance, making it compatible with global industrial standards. nVent’s reputation for engineering durable, high-performance electrical solutions is built on decades of innovation and customer trust. The ProLine G2 series reflects this legacy, offering a cost-effective alternative to custom-built enclosures without sacrificing quality or functionality. Whether upgrading existing infrastructure or deploying new systems, engineers and facility managers rely on ProLine G2 packages to deliver long-term protection, operational efficiency, and peace of mind in mission-critical applications.
  • Complete Type 12 enclosure package with integrated components
  • 1800x800x500mm dimensions for large control panels and automation equipment
  • Light gray powder-coated steel construction for corrosion resistance and visibility
  • Includes frame, solid doors with handle/key lock, top, rear cover, mounting subpanel, gland plate, and lifting eyes
  • Compatible with side covers (sold separately) for baying and modular expansion
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Door Quantity
2
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Max Rack Mount Unit
38
Max Subpanel Size
1706 x 728 mm
Max Subpanel Size
67.2 x 28.7 in
Product Family
ProLine
Type
Mild Steel Modular Industrial Enclosures
Width
31.8
Width
808
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom solution.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames, covers, and doors.

How do I install the internal components?

Internal components can be mounted using grid straps and various mounting brackets provided.

How to Install the P2BGP108 Controller

This guide provides step-by-step instructions for installing and configuring the P2BGP108 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BGP108 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the appropriate terminals on the controller. Follow the wiring diagram provided in the documentation.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure proper connection. Confirm that all connections are secure and correct.

  4. Configure the controller

    Access the controller's configuration interface via a web browser or dedicated software. Input the necessary settings as per your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the documentation to ensure the controller operates within specified parameters.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.