Authorized nVent Distributor
nVent P2KOD18164 - ProLine G2 Industrial Packages Type 12 2Dr, 1800x1600x400, Lt Gray, Steel

nVent P2KOD18164 ProLine G2 Industrial Packages Type 12 2Dr, 1800x1600x400, Lt Gray, Steel

UPC: 783510322588


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 Industrial Packages offer a streamlined and efficient solution for critical equipment protection. Designed for demanding industrial environments, these pre-configured enclosure systems eliminate the complexity of sourcing individual components, allowing for faster deployment and reduced project overhead. Each package, including this robust 1800x1600x400mm, 2-door model (SKU: P2KOD18164), is a comprehensive assembly, providing a single part number for unparalleled convenience. This ProLine G2 package includes a sturdy steel frame, two solid doors for enhanced security and environmental sealing, a high-security handle with an integrated key lock, a solid top panel, a solid rear cover, a full-sized mounting subpanel for component installation, a pre-punched gland plate for cable entry, and four robust lifting eyes for safe and easy handling during installation. The light gray powder-coat finish offers excellent corrosion resistance and a professional appearance suitable for a wide range of industrial settings. By consolidating essential enclosure elements into a single, ready-to-deploy unit, nVent significantly simplifies the procurement and assembly process. This approach is particularly beneficial for system integrators, panel builders, and end-users who require reliable, high-quality enclosures without the administrative burden of managing multiple vendor orders. The ProLine G2 series is engineered to meet stringent industry standards, ensuring the longevity and operational integrity of the housed electrical and electronic equipment. Key benefits of the nVent ProLine G2 Industrial Packages include: * **All-in-One Solution:** Reduces ordering complexity and lead times with a single part number. * **Robust Construction:** Made from durable steel with a protective light gray finish for superior longevity. * **Enhanced Security:** Features a secure handle and key lock system to protect sensitive equipment. * **Versatile Mounting:** Includes a full subpanel for flexible component arrangement and a gland plate for organized cable management. * **Ease of Installation:** Equipped with lifting eyes for straightforward rigging and placement. While side covers are ordered separately to facilitate seamless joining and baying of multiple enclosures, the core ProLine G2 package provides the foundational protection and functionality required for critical industrial applications. Trust nVent, a global leader in electrical enclosure solutions, to deliver the reliability and performance your operations demand. This Type 12 enclosure is designed to protect against falling dirt and the effects of circulating or splashing water, making it ideal for a multitude of manufacturing, process control, and automation environments.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
15.94
Depth
405
Door Quantity
2
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
38
Max Subpanel Size
1706 x 1528 mm
Max Subpanel Size
67.2 x 60.2 in
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2 Industrial Packages
Size
1800x1600x400
Type
Mild Steel Modular Industrial Enclosures
Weight
624 lb
Width
63.29
Width
1,608
Package Dimensions (L x W x H)
69 IN x 26 IN x 78.5 IN
Package Dimensions (L x W x H)
175.26 cm x 66.04 cm x 199.39 cm
Package Weight (Imperial)
624.000 L
Package Weight (Metric)
283.046 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What frame sizes are available for ProLine G2?

Available frame heights range from 600 mm to 2200 mm, with various widths and depths.

What materials are used for the ProLine G2 frame?

The frame is made from 12 gauge (2.5 mm) roll-formed steel.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

How do I configure my ProLine G2 enclosure?

Select components from the configuration handbook and send it to your nVent representative.

What accessories are available for cable management?

Accessories include cable entry cabinets, tie-down brackets, and wire management rails.

How do I contact nVent for support?

You can contact nVent via email at [email protected] or call their support numbers.

What is the weight capacity of the subpanel?

The subpanel can hold greater than 45% more weight than previous models.

What is the maximum load capacity for casters?

Casters can support a maximum load of 1000 lb (453.6 kg) when installed.

How can I maintain the environmental integrity of the enclosure?

Use foam-in-place gaskets and sealing options to maintain environmental integrity.

What is the purpose of the Ground Wire Kit?

The Ground Wire Kit allows grounding of the ProLine G2 enclosure to VDE specifications.

How to Install the P2KOD18164 PROLINE G2

Installation guide for mounting the P2KOD18164 PROLINE G2 enclosure.

Estimated time: 30m

Tools needed:

Screwdriver, Torque wrench

Supplies needed:

Mounting hardware

  1. Prepare Mounting Location

    Select a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Refer to the datasheet for specific weight information.

  2. Mount the Enclosure

    Using appropriate mounting hardware, secure the P2KOD18164 PROLINE G2 enclosure to the prepared mounting surface. Ensure the enclosure is level and firmly attached. For specific torque values, refer to the nameplate or datasheet.

  3. Install Internal Components (if applicable)

    If required, install any internal mounting panels, rails, or components according to their respective instructions. Ensure all components are securely fastened.

  4. Wire the Enclosure

    Connect any necessary power or control wiring to the enclosure's terminal blocks or entry points. Follow all applicable electrical codes and standards. Refer to the enclosure's wiring diagram for specific connections.

  5. Close and Secure the Enclosure

    Ensure all internal wiring is properly managed and secured. Close the enclosure door and fasten all latches or locking mechanisms securely.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.