Authorized nVent Distributor
nVent P2KOD16166 - ProLine G2 Industrial Packages Type 12 2Dr, 1600x1600x600, Lt Gray, Steel

nVent P2KOD16166 ProLine G2 Industrial Packages Type 12 2Dr, 1600x1600x600, Lt Gray, Steel

UPC: 783510322328


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 Industrial Packages, specifically the SKU P2KOD16166, represent a superior, pre-configured solution for demanding industrial environments. These Type 12 enclosures are engineered for robust protection against dust, dirt, and water, ensuring the integrity of sensitive electrical and electronic components. By offering a complete, ready-to-deploy package, nVent eliminates the complexity and time associated with sourcing individual enclosure parts, streamlining the procurement and installation process for engineers and facility managers. Each ProLine G2 package, including the 1600x1600x600mm model, is meticulously assembled to provide a comprehensive enclosure system. A single part number encompasses a sturdy steel frame, two solid doors for enhanced security and environmental sealing, a high-security handle with a key lock, a solid top panel, a solid rear cover, a full-sized mounting subpanel for component layout, a pre-cut gland plate for cable entry, and four robust lifting eyes for safe and easy handling during installation. This integrated approach ensures all critical enclosure elements are compatible and meet stringent industrial standards. While this package provides a complete standalone enclosure, nVent intelligently allows for customization and expansion. Side covers are ordered separately, facilitating seamless joining and baying of multiple enclosures to create larger, integrated control systems. This modularity is crucial for scalable industrial automation and control applications where space and functionality requirements evolve. Applications for the nVent ProLine G2 Industrial Packages are extensive, spanning various sectors including manufacturing, process control, water treatment, power distribution, and telecommunications. Their Type 12 rating makes them ideal for indoor use where protection against falling dirt, dripping water, and splashing water is paramount. The durable steel construction, finished in a light gray powder coating, offers excellent resistance to corrosion and mechanical stress, ensuring longevity even in harsh operational conditions. Key benefits of choosing the nVent ProLine G2 include: * **Time and Cost Savings:** Eliminates the need to order and assemble individual enclosure components. * **Guaranteed Compatibility:** All included parts are designed to work together seamlessly. * **Robust Protection:** Type 12 rating provides superior defense against environmental contaminants. * **Enhanced Security:** Integrated handle and key lock secure valuable equipment. * **Installation Flexibility:** Lifting eyes and optional side covers for baying offer practical installation and expansion options. * **Manufacturer Reliability:** nVent is a globally recognized leader in enclosure solutions, known for quality and innovation. When selecting an enclosure solution, professionals prioritize reliability, protection, and ease of integration. The nVent ProLine G2 Industrial Packages, with their thoughtful design and comprehensive feature set, deliver on all these fronts. The 1600x1600x600mm dimensions offer substantial internal volume, suitable for housing complex control panels, power supplies, and automation hardware. Trust nVent to provide the foundational protection your critical industrial equipment requires.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
2
Finish
Powder Coated
Height
63.07
Height
1,602
Material
Mild Steel
Max Rack Mount Unit
33
Max Subpanel Size
1506 x 1528 mm
Max Subpanel Size
59.3 x 60.2 in
Product Family
ProLine
Type
Mild Steel Modular Industrial Enclosures
Weight
404 lb
Width
63.29
Width
1,608
Package Dimensions (L x W x H)
50 IN x 30.5 IN x 70 IN
Package Dimensions (L x W x H)
127 cm x 77.47 cm x 177.8 cm
Package Weight (Imperial)
404.000 L
Package Weight (Metric)
183.254 kg
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What frame sizes are available for ProLine G2?

Available frame heights range from 600 mm to 2200 mm, with various widths and depths.

What materials are used for the ProLine G2 frame?

The frame is made from 12 gauge (2.5 mm) roll-formed steel.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

How do I configure my ProLine G2 enclosure?

Select components from the configuration handbook and send it to your nVent representative.

What accessories are available for cable management?

Accessories include cable entry cabinets, tie-down brackets, and wire management rails.

How do I contact nVent for support?

You can contact nVent via email at [email protected] or call their support numbers.

What is the weight capacity of the subpanel?

The subpanel can hold greater than 45% more weight than previous models.

What is the maximum load capacity for casters?

Casters can support a maximum load of 1000 lb (453.6 kg) when installed.

How can I maintain the environmental integrity of the enclosure?

Use foam-in-place gaskets and sealing options to maintain environmental integrity.

What is the purpose of the Ground Wire Kit?

The Ground Wire Kit allows grounding of the ProLine G2 enclosure to VDE specifications.

How to Install the P2KOD16166 PROLINE G2 Enclosure

Installation guide for mounting and wiring the P2KOD16166 PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Wire strippers, Wire crimpers, Pliers, Safety glasses, Gloves

Supplies needed:

Mounting hardware (screws, bolts, anchors), Wire, Wire connectors, Grommets, Strain relief fittings

  1. Plan the Installation Location

    Select a suitable location for the enclosure. Ensure there is adequate space for installation and maintenance, and that the environment is appropriate for the enclosure's rating. Refer to the datasheet for environmental specifications.

  2. Prepare the Mounting Surface

    Mark the mounting hole locations on the wall or mounting surface using a measuring tape and level. Ensure the marks are accurate and level. Drill pilot holes as required for your chosen mounting hardware. For specific hole patterns, consult the enclosure's datasheet.

  3. Mount the Enclosure

    Using the appropriate mounting hardware, securely attach the P2KOD16166 PROLINE G2 enclosure to the prepared mounting surface. Ensure the enclosure is level and firmly fixed. Verify that the mounting hardware is rated for the weight of the enclosure and its contents.

  4. Install Internal Components (if applicable)

    If your enclosure includes internal mounting panels or components, install them according to their specific instructions. Ensure all components are securely fastened.

  5. Plan Wire Routing

    Determine the best path for incoming and outgoing wires. Identify knockout locations or gland plates for cable entry and exit. Install appropriate grommets or strain relief fittings to protect wires.

  6. Make Electrical Connections

    Route wires into the enclosure through the prepared openings. Strip wire ends to the appropriate length (refer to component specifications). Connect wires to terminal blocks or devices using wire connectors and crimpers. Ensure all connections are secure and correctly identified. Follow all applicable electrical codes and standards. For specific wiring diagrams, consult the enclosure's documentation or the equipment being installed.

  7. Install Doors and Latches

    Attach the enclosure door(s) and ensure latches operate correctly. Check that the door seals are properly seated to maintain the enclosure's environmental rating.

  8. Final Inspection and Testing

    Perform a thorough visual inspection of the installation. Verify all connections are tight and correctly made. Test the functionality of the installed equipment according to its operational requirements. Ensure all safety guards and covers are in place.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.