The nVent ProLine G2 Disconnect Package (SKU: P2KDR2085) is a premium, ready-to-install industrial enclosure designed to simplify the creation of flange-mount disconnect solutions. Engineered for durability and ease of use, this Type 12-rated package features a 2000x800x500mm footprint in light gray steel, providing robust protection for critical electrical components in demanding environments. As part of the ProLine G2 series from nVent—a trusted leader in thermal management and electrical protection solutions—this package delivers unmatched reliability and performance for professionals who demand precision and efficiency in their installations. At the heart of the ProLine G2 Disconnect Package is a full-featured design that eliminates the need for custom fabrication. The enclosure arrives pre-assembled with a hinged disconnect mullion, ensuring unobstructed access to the interior and maximizing space for the Full Mounting Subpanel (Mounting Plate). This thoughtful design allows for seamless integration of major brand disconnect switches and circuit breakers, making it an ideal choice for OEMs, panel builders, and electrical contractors seeking to streamline their workflow. The flush swing handle with a defeater operates an internal 3-point latch system on the disconnect door, providing secure closure while allowing for easy access when maintenance or adjustments are required. Interlocking functionality between the primary door and the disconnect mullion enhances safety by preventing accidental access to live components during operation. This feature is particularly valuable in industrial settings where compliance with OSHA and NEC standards is critical. The included side covers further enhance the enclosure's versatility, offering additional protection against dust, debris, and moisture while maintaining a clean, professional appearance. The light gray steel construction not only provides superior durability but also ensures compatibility with a wide range of industrial aesthetics. Typical applications for the ProLine G2 Disconnect Package include motor control centers, HVAC systems, industrial machinery, and renewable energy installations. Its robust construction and Type 12 rating make it suitable for use in harsh environments, including manufacturing plants, warehouses, and outdoor installations where exposure to contaminants is a concern. Professionals in the electrical, automation, and industrial sectors rely on nVent's ProLine G2 series for its consistency, quality, and adherence to industry standards. Whether you're retrofitting an existing system or designing a new installation, this disconnect package offers the flexibility and reliability needed to meet the demands of modern industrial applications. Choosing the right disconnect package is essential for ensuring the safety and efficiency of your electrical systems. The nVent ProLine G2 Disconnect Package stands out for its ease of installation, comprehensive features, and compatibility with leading brands. Its modular design allows for quick integration into existing systems, reducing downtime and labor costs. Additionally, nVent's reputation for innovation and quality ensures that this product will deliver long-term performance, backed by industry-leading warranties and support. For engineers, contractors, and facility managers seeking a dependable, ready-to-use disconnect solution, the ProLine G2 Disconnect Package is an investment in reliability and peace of mind. Trust in nVent's expertise to provide the protection and performance your operations demand.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Controls and Drives; Arc Flash Safety
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Door Quantity
1
Finish
Powder Coated
Height
78.82
Height
2,002
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
42
Max Subpanel Size
1906 x 728 mm
Max Subpanel Size
75.0 x 28.7 in
Mounting Type
Flange-mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
2000x800x500 mm
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
409 lb
Width
31.8
Width
808
Package Dimensions (L x W x H)
38 IN x 26 IN x 80 IN
Package Dimensions (L x W x H)
96.52 cm x 66.04 cm x 203.2 cm
Package Weight (Imperial)
409.000 L
Package Weight (Metric)
185.522 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

How can I contact nVent for configuration help?

You can contact nVent via email at [email protected] or call 763 422 2211.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What materials are used in the ProLine G2 frame?

The frame is made from 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb (453.6 kg).

Can I customize the ProLine G2 enclosure?

Yes, the ProLine G2 can be customized using a comprehensive set of standard components and accessories.

What are the available frame dimensions?

Frame heights range from 600 mm to 2200 mm, with various width and depth options.

What type ratings are available for the ProLine G2?

The ProLine G2 is available in Type 12 and Type 3R ratings.

What safety features are included in the ProLine G2?

Safety features include mechanical and electrical interlocks, grounding studs, and optional tamperproof hardware.

What options are available for cable management?

Cable management options include cable entry cabinets, vertical tie-downs, and various cable management accessories.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

How to Install the P2KDR2085 Controller

This guide provides step-by-step instructions for installing and configuring the P2KDR2085 Controller, ensuring proper wiring and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2KDR2085 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated terminals on the controller. Ensure the connections are tight to prevent any loose wiring.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. Confirm that all connections are secure and properly insulated.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the required parameters according to your application needs.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.