Authorized nVent Distributor
nVent P2KDR18166 - ProLine G2 Disconnect Package Type 12 RH 2Dr, 1800x1600x600, Lt Gray, Steel

nVent P2KDR18166 ProLine G2 Disconnect Package Type 12 RH 2Dr, 1800x1600x600, Lt Gray, Steel

UPC: 783510321734


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent ProLine G2 Disconnect Package (SKU: P2KDR18166)** delivers a pre-engineered, Type 12-rated enclosure designed for industrial and commercial disconnect solutions. This 1800x1600x600mm (2-door) package simplifies installation by integrating a full-featured enclosure with a hinged disconnect mullion, providing unobstructed access to the interior and a Full Mounting Subpanel for easy component mounting. Engineered for durability and compliance, the ProLine G2 series is ideal for environments requiring robust protection against dust, dirt, and water ingress, making it a trusted choice for panel builders, electrical contractors, and facility managers across multiple industries. **Key Features & Benefits:** - **Type 12 Rated Enclosure**: Designed to protect against dust, dirt, and non-corrosive liquids, ensuring reliable performance in harsh industrial environments. The right-hand (RH) orientation and 2-door design optimize accessibility for maintenance and upgrades. - **Hinged Disconnect Mullion**: Provides maximum interior access while maintaining structural integrity. The mullion’s design allows for seamless integration with major brand disconnect switches and circuit breakers, reducing installation time and complexity. - **Flush Swing Handle with Defeater**: Operates a 3-point latch system on the disconnect door, enhancing security and safety. The defeater mechanism ensures compliance with lockout/tagout (LOTO) protocols, critical for OSHA and NFPA 70E adherence. - **Interlocking System**: Primary door interlocks with the disconnect mullion, preventing accidental access to energized components. This feature is essential for meeting NEC and IEC safety standards in high-risk applications. - **Included Side Covers**: Pre-fitted side panels streamline installation and ensure consistent enclosure integrity, reducing the need for additional fabrication or customization. **Typical Applications:** The ProLine G2 Disconnect Package is widely used in **manufacturing plants, data centers, water treatment facilities, and commercial buildings** where reliable power distribution and safety are paramount. Common use cases include: - **Motor Control Centers (MCCs)**: Housing disconnect switches and circuit breakers for motor starters, ensuring quick isolation for maintenance. - **HVAC Systems**: Managing power distribution for rooftop units (RTUs) and chillers in industrial and commercial settings. - **Industrial Machinery**: Providing safe, accessible disconnect solutions for CNC machines, conveyors, and automated production lines. - **Renewable Energy Systems**: Integrating disconnect switches in solar and wind power installations for grid-tied or off-grid applications. **Why Choose nVent ProLine G2?** nVent, a global leader in electrical and thermal management solutions, designs the ProLine G2 series with **engineering precision and compliance** in mind. The enclosures meet **UL 508A, NEMA Type 12, and IP54** standards, ensuring they withstand demanding conditions while simplifying installation and maintenance. The **pre-engineered design** reduces labor costs and minimizes the risk of errors, making it a cost-effective choice for both new constructions and retrofits. **Installation & Compliance Considerations:** Professionals select the ProLine G2 for its **modularity and ease of integration** with industry-standard disconnect switches (e.g., Eaton, ABB, Siemens). The **Full Mounting Subpanel** accommodates a variety of components, while the **hinged mullion** allows for tool-less access during commissioning or troubleshooting. For compliance, ensure the enclosure is properly grounded and that the disconnect switch is rated for the application’s voltage and current requirements. nVent provides detailed **installation guides and CAD drawings** to streamline the process. **Industry Trust & Support:** With a reputation for innovation and reliability, nVent’s ProLine G2 Disconnect Packages are backed by **global distribution networks, technical support, and a 5-year warranty**. Whether you’re retrofitting an existing system or designing a new facility, the ProLine G2 delivers **safety, durability, and performance**—making it a preferred choice for electrical professionals worldwide.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
2
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
38
Max Subpanel Size
1706 x 1528 mm
Max Subpanel Size
67.2 x 60.2 in
Mounting Type
Flange-mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1800x1600x600
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
190 lb
Width
63.29
Width
1,608
Package Dimensions (L x W x H)
62 IN x 60 IN x 36 IN
Package Dimensions (L x W x H)
157.48 cm x 152.4 cm x 91.44 cm
Package Weight (Imperial)
400.000 L
Package Weight (Metric)
181.440 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

How can I contact nVent for support?

You can contact nVent via email at [email protected] or call HOFFMAN-USA at 763 422 2211.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What are the available frame dimensions?

Frame heights range from 600 mm to 2200 mm, with widths and depths varying accordingly.

What options are available for cable management?

Options include cable entry cabinets, vertical tie-down cable managers, and wire management rails.

What safety features are included with the ProLine G2?

Safety features include disconnect doors, mechanical and electrical interlocks, and anti-tip brackets.

What is the maximum load for the pull-out shelf?

The pull-out shelf has a load rating of 110 lbs. (50 kg).

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What type ratings are available for the ProLine G2?

The ProLine G2 is available in Type 12 and Type 3R ratings.

How can I ensure proper grounding for the enclosure?

Use the Ground Wire Kit or Ground Plate Kit to effectively ground the enclosure to VDE specifications.

How to Install the PROLINE G2 Disconnect

This guide provides step-by-step instructions for installing the PROLINE G2 disconnect door and configuring it for safe operation.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Terminal connectors, Shoulder collars, Hex nuts

  1. Install the disconnect door

    Follow the disconnect door installation instructions to securely attach the PROLINE G2 disconnect door and disconnect mullion to the modular frame.

  2. Attach the operating handle

    Install the disconnect/circuit breaker operating handle on the disconnect mullion according to the manufacturer's instructions. Remove the pivot bracket as shown in the installation guide.

  3. Secure the pivot bracket

    Position the pivot bracket so that the interlock lever fits between the adjustable studs. Secure the pivot bracket to the disconnect mullion using the shoulder collar and hex nut.

  4. Close and latch the mullion

    Close and latch the disconnect mullion to the PROLINE G2 frame using the sliding latches provided at the top and bottom.

  5. Adjust the door interlock

    Adjust the studs on the pivot bracket so that it is horizontal when the disconnect operating handle is in the 'OFF' position. Ensure proper engagement with the door catch.

  6. Drill mounting holes

    Drill the necessary mounting holes in the subpanel for the specific disconnect switch/circuit breaker being installed, following the manufacturer's instructions.

  7. Install the subpanel

    Install the subpanel in the PROLINE G2 frame at the desired depth, ensuring it is within the recommended depth range for the disconnect.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.