nVent P2KDR18124 - ProLine G2 Disconnect Package Type 12 RH 2Dr, 1800x1200x400, Lt Gray, Steel
nVent

P2KDR18124

UPC: 783510321727


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Disconnect Package (SKU: P2KDR18124) represents a superior solution for creating robust, flange-mount disconnect switch and circuit breaker installations. Engineered for demanding industrial environments, this Type 12 enclosure offers comprehensive protection against dust, dirt, and water, ensuring the longevity and reliability of your critical electrical components. The generous dimensions of 1800x1200x400mm provide ample space for a wide array of disconnect switches and circuit breakers from leading manufacturers, facilitating flexible system design and integration. Designed with the installer and end-user in mind, the ProLine G2 Disconnect Package features a thoughtfully engineered hinged disconnect mullion. This innovative design grants unobstructed access to the enclosure's interior and maximizes usability of the full mounting subpanel (mounting plate). This ease of access is crucial for efficient installation, maintenance, and troubleshooting, minimizing downtime and operational disruptions. The enclosure's primary door is equipped with a flush swing handle that operates an internal 3-point latch system, ensuring a secure and reliable seal. This robust latching mechanism, combined with a defeater for controlled access, enhances safety and security. Further enhancing operational safety, the ProLine G2 Disconnect Package incorporates interlocking functionality. This feature provides a secure connection from the primary door to the disconnect mullion, preventing accidental opening of the disconnect compartment while the main enclosure is accessed. This layered safety approach is paramount in industrial settings where electrical hazards are a constant concern. The package also includes essential side covers, contributing to a complete and finished installation that meets stringent industry standards. Constructed from durable steel and finished in a light gray hue, this enclosure not only offers exceptional protection but also presents a professional appearance suitable for any industrial facility. The UNSPSC code 39121334 categorizes this product within electrical equipment and accessories, underscoring its role in essential power distribution and control systems. nVent's commitment to quality and innovation is evident in the ProLine G2 Disconnect Package, making it an ideal choice for applications requiring reliable and safe disconnect solutions. Typical applications include motor control centers, power distribution panels, and control systems in manufacturing plants, processing facilities, and other heavy industrial environments. The US country of origin further assures adherence to high manufacturing standards. Key features include: * **Robust Type 12 Protection:** Safeguards internal components from dust, dirt, and water ingress. * **Spacious Interior:** 1800x1200x400mm dimensions accommodate various disconnect switches and circuit breakers. * **Hinged Disconnect Mullion:** Provides unobstructed interior access and maximum subpanel usability. * **Secure 3-Point Latching:** Flush swing handle with defeater ensures a tight seal and enhanced safety. * **Integrated Interlocking:** Prevents unauthorized access to the disconnect compartment. * **Durable Steel Construction:** Light gray finish for longevity and professional aesthetics. * **Complete Package:** Includes side covers for a finished installation. When selecting disconnect enclosures, professionals prioritize durability, ease of installation, and safety features. The nVent ProLine G2 Disconnect Package excels in all these areas, offering a reliable and efficient solution for critical electrical infrastructure. Trust nVent for your industrial enclosure needs.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
15.94
Depth
405
Door Quantity
2
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
38
Max Subpanel Size
67.2 x 44.4 in
Max Subpanel Size
1706 x 1128 mm
Mounting Type
Flange-mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1800x1200x400
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
190 lb
Width
47.54
Width
1,208
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What frame sizes are available for ProLine G2?

Available frame heights range from 600 mm to 2200 mm, with various widths and depths.

What materials are used for the ProLine G2 frame?

The frame is made from 12 gauge (2.5 mm) roll-formed steel.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

How do I configure my ProLine G2 enclosure?

Select components from the configuration handbook and send it to your nVent representative.

What accessories are available for cable management?

Accessories include cable entry cabinets, tie-down brackets, and wire management rails.

How do I contact nVent for support?

You can contact nVent via email at [email protected] or call their support numbers.

What is the weight capacity of the subpanel?

The subpanel can hold greater than 45% more weight than previous models.

What is the maximum load capacity for casters?

Casters can support a maximum load of 1000 lb (453.6 kg) when installed.

How can I maintain the environmental integrity of the enclosure?

Use foam-in-place gaskets and sealing options to maintain environmental integrity.

What is the purpose of the Ground Wire Kit?

The Ground Wire Kit allows grounding of the ProLine G2 enclosure to VDE specifications.

How to Install the P2BGP108 Controller

This guide provides step-by-step instructions for installing and configuring the P2BGP108 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BGP108 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the appropriate terminals on the controller. Follow the wiring diagram provided in the documentation.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure proper connection. Confirm that all connections are secure and correct.

  4. Configure the controller

    Access the controller's configuration interface via a web browser or dedicated software. Input the necessary settings as per your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the documentation to ensure the controller operates within specified parameters.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.