nVent P2KDR18106 - ProLine G2 Disconnect Package Type 12 RH 1Dr, 1800x1000x600, Lt Gray, Steel
nVent

P2KDR18106

UPC: 783510321680


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Disconnect Package (SKU: P2KDR18106) offers a robust and ready-to-deploy solution for creating integrated disconnect switch and circuit breaker enclosures. Engineered for demanding industrial environments, this Type 12 rated package provides superior protection against dust and water ingress, ensuring the reliability of critical electrical components. Its substantial dimensions of 1800x1000x600mm, finished in a light gray steel, accommodate a wide range of disconnect switches and circuit breakers from major manufacturers, simplifying the design and installation process for electrical engineers and system integrators. The ProLine G2 Disconnect Package is meticulously designed for ease of use and maximum accessibility. A key feature is the hinged disconnect mullion, which swings open to provide unobstructed access to the enclosure's interior. This design significantly enhances convenience during installation, maintenance, and troubleshooting. Furthermore, it offers maximum access to the Full Mounting Subpanel (Mounting Plate), allowing for flexible and secure mounting of electrical equipment. The enclosure is equipped with a flush swing handle that incorporates a defeater mechanism, operating an internal 3-point latch system on the disconnect door. This robust latching system ensures secure closure and reliable operation. Safety and operational integrity are paramount with the ProLine G2 Disconnect Package. Interlocking is seamlessly provided from the primary enclosure door to the disconnect mullion, preventing unauthorized access to live components during operation and ensuring a safe sequence of operations. This feature is critical in preventing electrical hazards and maintaining compliance with safety standards. The package also includes essential side covers, contributing to a complete and finished installation. Built with nVent's commitment to quality and durability, the ProLine G2 Disconnect Package is constructed from high-grade steel, offering excellent mechanical strength and corrosion resistance. The light gray finish not only provides a professional aesthetic but also helps to reflect heat, contributing to a stable internal operating temperature for sensitive electrical equipment. This enclosure is ideal for a variety of applications, including: * Motor control centers * Power distribution systems * Industrial automation * Machine control panels * Hazardous location applications (when properly specified and installed) Choosing the nVent ProLine G2 Disconnect Package means investing in a reliable, efficient, and safe solution for your electrical enclosure needs. Its thoughtful design, premium materials, and comprehensive feature set make it a preferred choice for professionals seeking to streamline their disconnect switch integration projects while ensuring long-term performance and safety. The "RH" designation typically indicates a right-hand door swing, a crucial detail for installation planning. This package exemplifies nVent's expertise in providing comprehensive enclosure solutions that meet the rigorous demands of modern industrial electrical installations. The integration of disconnect switches and circuit breakers within a single, protected enclosure simplifies wiring, reduces installation time, and enhances overall system reliability and safety.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Controls and Drives; Arc Flash Safety
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
1
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
38
Max Subpanel Size
1706 x 928 mm
Max Subpanel Size
67.2 x 36.5 in
Mounting Type
Flange-mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1800x1000x600 mm
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
300 lb
Width
39.67
Width
1,008
Package Dimensions (L x W x H)
1 IN x 1 IN x 1 IN
Package Dimensions (L x W x H)
2.54 cm x 2.54 cm x 2.54 cm
Package Weight (Imperial)
300.000 L
Package Weight (Metric)
136.080 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What frame heights are available for ProLine G2?

Available frame heights include 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, and 2200 mm.

What frame sizes are available for ProLine G2?

Available frame heights range from 600 mm to 2200 mm, with various widths and depths.

What materials are used for the ProLine G2 frame?

The frame is made from 12 gauge (2.5 mm) roll-formed steel.

What is the maximum load for the pull-out shelf?

The pull-out shelf has a load rating of 110 lbs (50 kg).

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What materials are used for the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

How can I contact nVent for configuration help?

You can contact nVent via email at [email protected] or call HOFFMAN-USA at 763 422 2211.

What is the weight capacity of the mobile base?

The mobile base provides a load-bearing capacity of 1000 lb (453.6 kg).

What accessories are available for cable management?

Accessories include cable entry cabinets, tie-down brackets, and wire management rails.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

How to Install the P2K1686 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1686 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2K1686 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure the connections are secure to prevent any power loss.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters as per your system requirements. Save the settings once completed.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates within the desired parameters. Make adjustments as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.