Authorized nVent Distributor
nVent P2KDR1686 - ProLine G2 Disconnect Package Type 12 RH 1Dr, 1600x800x600, Lt Gray, Steel

nVent P2KDR1686 ProLine G2 Disconnect Package Type 12 RH 1Dr, 1600x800x600, Lt Gray, Steel

UPC: 783510321659


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 Disconnect Package (SKU: P2KDR1686) represents a superior solution for creating robust, flange-mount disconnect switch and circuit breaker installations. Engineered for demanding industrial environments, this Type 12 enclosure offers comprehensive protection against dust, dirt, and oil, ensuring the longevity and reliability of critical electrical components. Its substantial dimensions of 1600x800x600mm provide ample space for a wide array of disconnect switches and circuit breakers from major manufacturers, facilitating flexible system design and integration. At the core of the ProLine G2 Disconnect Package's design is its user-centric approach to accessibility and safety. The innovative hinged disconnect mullion swings open to offer unobstructed access to the enclosure's interior. This design maximizes the usable space and allows for effortless installation and maintenance of the full mounting subpanel (mounting plate). Professionals will appreciate the ease with which components can be mounted and wired, reducing installation time and potential errors. The enclosure features a flush swing handle equipped with a defeater mechanism, which reliably operates an internal 3-point latch system on the disconnect door. This robust latching mechanism ensures a secure seal, further enhancing the enclosure's protective capabilities. Furthermore, the system is designed for integrated safety, with interlocking provided from the primary door to the disconnect mullion, preventing unauthorized access or operation during critical phases. Included as standard with the ProLine G2 Disconnect Package are side covers, which contribute to the overall structural integrity and aesthetic finish of the enclosure. Constructed from durable steel and finished in a light gray powder coating, this unit is built to withstand harsh operational conditions while maintaining a professional appearance. The UNSPSC code 39121334 categorizes this product within electrical equipment and accessories, highlighting its essential role in industrial power distribution and control systems. Manufactured in the USA, nVent's ProLine G2 Disconnect Packages embody a commitment to quality, innovation, and dependable performance, making them the preferred choice for engineers and facility managers seeking reliable disconnect solutions. Key features and benefits include: * **Robust Construction:** Heavy-duty steel enclosure with a Type 12 rating for superior protection. * **Optimized Accessibility:** Hinged disconnect mullion for unimpeded interior access and subpanel mounting. * **Secure Latching:** Flush swing handle with a 3-point latch system and defeater for enhanced safety. * **Integrated Interlocking:** Safety interlock between the primary door and disconnect mullion. * **Ample Space:** Generous dimensions (1600x800x600mm) accommodate various disconnect switches and circuit breakers. * **Complete Solution:** Includes side covers for a finished installation. * **Trusted Manufacturer:** nVent's reputation for quality and reliability in enclosure solutions. This disconnect package is ideal for applications in manufacturing plants, processing facilities, power generation, and any industrial setting requiring safe and accessible disconnect switch mounting. Its design simplifies the creation of flange-mount disconnect solutions, reducing complexity and ensuring compliance with industry standards.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
1
Finish
Powder Coated
Height
63.07
Height
1,602
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
33
Max Subpanel Size
59.3 x 28.7 in
Max Subpanel Size
1506 x 728 mm
Mounting Type
Flange-mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2 Disconnect
Size
1600x800x600 mm
Thickness
14 ga
Thickness
1.9 mm
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
190 lb
Width
31.8
Width
808
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths available.

What accessories are available for cable management?

ProLine G2 offers various cable management accessories, including cable entry cabinets, tie-down brackets, and wire management rails.

What is the maximum weight capacity for the subpanel?

The subpanel can hold greater than 45% more weight than previous models, accommodating heavier electronics.

What type ratings are available for ProLine G2 enclosures?

ProLine G2 enclosures are available in Type 12 and Type 3R ratings.

How can I ensure proper grounding for the enclosure?

Use the Ground Wire Kit or Ground Plate Kit to effectively ground the enclosure to VDE specifications.

What safety features are included in the ProLine G2?

Safety features include mechanical and electrical interlocks, grounding options, and tamperproof hardware kits.

What is the purpose of the mechanical interlock?

The mechanical interlock prevents secondary doors from opening until the primary door is opened and the disconnect switch is thrown.

What is the recommended installation for partial doors?

Partial doors require a custom frame and internal barrier panels for proper installation.

How to Safely Handle and Install a Hoffman Enclosure

Follow these instructions for the safe handling and installation of your Hoffman enclosure. Always prioritize safety and refer to the nameplate or datasheet for specific model information.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device, Slings with hooks or shackles, Chain or strap (3000 lb-rated)

Supplies needed:

Mounting screws, ROLL•A•LIFT™ or similar device

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and workers are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. If using a forklift, know its safe lifting capabilities and ensure it can handle the enclosure's weight and size. Always use both forks and position the enclosure far back on the forks, keeping the load against the carriage and tilting the load backwards towards the mast.

  3. Secure Enclosure for Transport

    If using a forklift, secure the enclosure to the forklift mast using a 3000 lb-rated chain or strap through the provided eye bolts. Ensure sufficient tension to prevent tipping. If using an overhead lifting device, attach rigging to eye bolts, maintaining a maximum 45° angle between lifting cables and the vertical. Use slings with adequate load-rated hooks or shackles, not ropes or cables.

  4. Move the Enclosure

    Start and stop the forklift slowly and gradually. Drive slowly with the forks as low to the ground as possible. For overhead lifting, select or adjust rigging lengths to compensate for any unequal weight distribution and support the enclosure in an upright position. Do not attempt to lift the enclosure completely off the ground if using a forklift with a clamping device.

  5. Position the Enclosure

    Carefully position the enclosure on the forks or in its final location. Ensure it is stable and does not contact fixed objects. If using a ROLL•A•LIFT™ or similar device for multi-door enclosures, place it under one end and lift that end slightly while the forklift handles the other.

  6. Final Installation Checks

    Verify that the enclosure is level, firmly installed, and all safety precautions have been followed. Re-check tension on any securing chains or straps. Refer to the nameplate or datasheet for any model-specific installation details not covered here.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.