nVent P2KDR16166 - ProLine G2 Disconnect Package Type 12 RH 2Dr, 1600x1600x600, Lt Gray, Steel
nVent

P2KDR16166

UPC: 783510321635


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The **nVent ProLine G2 Disconnect Package (SKU: P2KDR16166)** is a pre-engineered, Type 12-rated industrial enclosure designed for seamless integration with major brand disconnect switches and circuit breakers. This **1600x1600x600mm (2-door) right-hand (RH) package** in light gray steel provides a robust, ready-to-install solution for flange-mount disconnect applications, eliminating the need for custom fabrication and reducing project timelines. Built for durability and ease of use, the ProLine G2 package is ideal for environments where reliable power distribution and equipment protection are critical. **Key Features & Benefits** The ProLine G2 Disconnect Package is engineered with **industry-leading features** to enhance safety, accessibility, and installation efficiency. A **hinged disconnect mullion** ensures unobstructed access to the interior, while the **Full Mounting Subpanel (Mounting Plate)** maximizes space utilization for switches and breakers. The **flush swing handle with defeater** operates a **3-point latch system** on the disconnect door, providing secure closure and preventing accidental openings. Interlocking between the primary door and disconnect mullion enhances safety by ensuring proper sequencing during maintenance. **Side covers** are included for additional protection and compliance with Type 12 standards. **Typical Applications & Industries** This disconnect package is widely used in **manufacturing plants, data centers, commercial buildings, and industrial facilities** where reliable power distribution is essential. It is particularly suited for **motor control centers, HVAC systems, and machinery disconnect applications**, where Type 12 enclosures are required to protect against dust, dirt, and non-corrosive liquids. The **right-hand (RH) configuration** makes it ideal for wall-mounted installations where space optimization and accessibility are priorities. Professionals in **electrical contracting, facility management, and industrial automation** rely on nVent’s ProLine G2 for its **pre-engineered design, compliance with NEMA Type 12 standards**, and compatibility with leading disconnect switch brands. **Why Choose nVent ProLine G2?** nVent is a globally recognized leader in **electrical and thermal management solutions**, with a reputation for innovation and reliability. The ProLine G2 Disconnect Package reflects this commitment, offering **pre-tested, code-compliant solutions** that simplify installation and reduce labor costs. Unlike generic enclosures, this package is **engineered for seamless integration** with disconnect switches and circuit breakers, ensuring optimal performance and safety. The **light gray steel construction** provides corrosion resistance and durability, while the **modular design** allows for future upgrades or reconfigurations. **Installation & Compliance Considerations** The ProLine G2 Disconnect Package is designed for **quick and straightforward installation**, with pre-drilled mounting holes and integrated side covers for added convenience. It meets **NEMA Type 12** standards, making it suitable for harsh industrial environments. Professionals should ensure proper **grounding, ventilation, and clearance** during installation to maintain performance and safety. nVent provides **comprehensive documentation**, including installation guides and compliance certificates, to support engineers and contractors in achieving code-compliant installations. **Industry Trust & Support** With decades of experience in electrical enclosure solutions, nVent’s ProLine G2 Disconnect Package is backed by **global support, technical expertise, and a commitment to quality**. Whether for new construction, retrofits, or system upgrades, this package delivers **reliable performance, safety, and ease of use**—making it a preferred choice for professionals who demand the best in industrial power distribution.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
2
Finish
Powder Coated
Height
63.07
Height
1,602
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
33
Max Subpanel Size
1506 x 1528 mm
Max Subpanel Size
59.3 x 60.2 in
Mounting Type
Flange-mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1600x1600x600
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
190 lb
Width
63.31
Width
1,608
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What frame sizes are available for ProLine G2?

Available frame heights range from 600 mm to 2200 mm, with various widths and depths.

What materials are used for the ProLine G2 frame?

The frame is made from 12 gauge (2.5 mm) roll-formed steel.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

How do I configure my ProLine G2 enclosure?

Select components from the configuration handbook and send it to your nVent representative.

What accessories are available for cable management?

Accessories include cable entry cabinets, tie-down brackets, and wire management rails.

How do I contact nVent for support?

You can contact nVent via email at [email protected] or call their support numbers.

What is the weight capacity of the subpanel?

The subpanel can hold greater than 45% more weight than previous models.

What is the maximum load capacity for casters?

Casters can support a maximum load of 1000 lb (453.6 kg) when installed.

How can I maintain the environmental integrity of the enclosure?

Use foam-in-place gaskets and sealing options to maintain environmental integrity.

What is the purpose of the Ground Wire Kit?

The Ground Wire Kit allows grounding of the ProLine G2 enclosure to VDE specifications.

How to Install the P2K1846 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1846 Controller, ensuring proper setup and functionality.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1846 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Verify the connections are tight and secure.

  3. Configure the controller settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements and save the settings.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual. Use a multimeter to verify output signals and adjust settings as necessary for accurate performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.