Overview

The nVent ProLine G2 Disconnect Package (SKU: P2KDL22185) is a robust, pre-configured enclosure solution designed for seamless integration of major brand disconnect switches and circuit breakers. Engineered for demanding industrial environments, this Type 12 enclosure offers superior protection against dust, dirt, and water, ensuring the longevity and reliability of your critical electrical components. Its generous dimensions of 2200x1800x500mm provide ample space for complex wiring and component layouts, while the left-hand (LH) door configuration offers installation flexibility. At the core of the ProLine G2 Disconnect Package is its innovative hinged disconnect mullion. This design element grants unobstructed access to the enclosure's interior, facilitating easier installation, maintenance, and troubleshooting. Furthermore, it maximizes access to the Full Mounting Subpanel (Mounting Plate), allowing for efficient and secure mounting of disconnect switches and circuit breakers. The enclosure features a flush swing handle with a defeater mechanism, which operates an internal 3-point latch system on the disconnect door. This robust latching system ensures a secure closure, protecting sensitive electrical equipment from environmental ingress and unauthorized access. The handle also latches directly to the disconnect mullion, providing an additional layer of security and structural integrity. Safety is paramount in industrial electrical installations, and the ProLine G2 Disconnect Package addresses this with integrated interlocking capabilities. Interlocking is provided from the primary door to the disconnect mullion, preventing accidental operation or access while the system is energized. This feature is crucial for maintaining a safe working environment and complying with stringent industrial safety standards. The package also includes essential side covers, contributing to a complete and polished installation. Constructed from durable steel with a light gray finish, this enclosure is built to withstand the rigors of industrial applications. The ProLine G2 Disconnect Package is an ideal choice for applications requiring reliable and secure disconnect solutions in sectors such as manufacturing, processing, and utility infrastructure. Trust nVent, a global leader in electrical enclosure solutions, for dependable performance and advanced design. Key Features: * **Comprehensive Disconnect Solution:** Ready-to-use package for integrating major brand disconnect switches and circuit breakers. * **Robust Construction:** Durable steel enclosure with a Type 12 rating for protection against dust, dirt, and water. * **Optimized Access:** Hinged disconnect mullion provides unobstructed interior access and full access to the mounting subpanel. * **Secure Latching:** Flush swing handle with defeater operates a 3-point latch system on the disconnect door and latches to the mullion. * **Enhanced Safety:** Integrated interlocking from the primary door to the disconnect mullion for operational safety. * **Generous Capacity:** Dimensions of 2200x1800x500mm accommodate complex electrical configurations. * **Installation Flexibility:** Left-hand (LH) door configuration. * **Complete Package:** Includes side covers for a finished installation. Applications: * Industrial automation and control systems * Power distribution and management * Machine control panels * Process control applications * Harsh environmental installations Manufacturer: nVent SKU: P2KDL22185 UNSPSC Code: 39121334 Country of Origin: US
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Controls and Drives; Arc Flash Safety
Color
Light Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Door Quantity
2
Finish
Powder Coated
Height
86.69
Height
2,202
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
47
Max Subpanel Size
2106 x 1728 mm
Max Subpanel Size
82.9 x 68.0 in
Mounting Type
Left-hand (LH) door configuration
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
2200x1800x500 mm
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
600 lb
Width
71.17
Width
1,808
Package Dimensions (L x W x H)
86.7 IN x 71.2 IN x 19.9 IN
Package Dimensions (L x W x H)
220.218 cm x 180.848 cm x 50.546 cm
Package Weight (Imperial)
600.000 L
Package Weight (Metric)
272.160 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom solution.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames, covers, and doors.

How do I install the internal components?

Internal components can be mounted using grid straps and various mounting brackets provided.

How to Install the P2KDL22185 PROLINE G2

Installation guide for mounting the P2KDL22185 PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver set, Pliers, Wire cutters, Wire strippers

Supplies needed:

Mounting hardware (screws, anchors), Wire connectors, Grounding lug, Grounding wire

  1. Plan the Mounting Location

    Select a suitable location for the enclosure. Ensure there is adequate space for installation and future access. Check the enclosure's dimensions against the available space. Refer to the datasheet for specific clearance requirements.

  2. Prepare the Mounting Surface

    Mark the mounting hole locations on the wall or mounting surface using the enclosure's mounting template or by measuring. Ensure the marks are level. Drill pilot holes as needed, considering the type of wall material and the required mounting hardware.

  3. Mount the Enclosure

    Securely attach the enclosure to the mounting surface using appropriate mounting hardware. Ensure the enclosure is level and firmly fixed. Verify that the mounting is robust enough to support the weight of the enclosure and its contents.

  4. Install Grounding

    Connect the grounding wire to the designated grounding lug inside the enclosure and to the building's grounding system. Ensure a secure and reliable ground connection. Refer to local electrical codes for proper grounding procedures.

  5. Prepare for Internal Components

    Remove any internal mounting panels or components as necessary to facilitate wiring. Plan the layout of internal equipment, considering cable routing and accessibility.

  6. Wire Internal Components

    Install and wire any internal components according to their respective documentation. Use appropriate wire sizes and connectors. Ensure all connections are secure and properly insulated. Follow all applicable electrical codes and safety standards.

  7. Close and Secure the Enclosure

    Once all internal wiring and component installation is complete, close the enclosure door and secure it with the provided latches or locks. Ensure the door seals properly to protect the internal components from the environment.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.