Authorized nVent Distributor
nVent P2KDL22124 - ProLine G2 Disconnect Package Type 12 LH 2Dr, 2200x1200x400, Lt Gray, Steel

nVent P2KDL22124 ProLine G2 Disconnect Package Type 12 LH 2Dr, 2200x1200x400, Lt Gray, Steel

UPC: 783510321512


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent ProLine G2 Disconnect Package (SKU: P2KDL22124)** delivers a pre-engineered, ready-to-install solution for industrial disconnect applications, combining robust construction with intuitive access and safety features. Designed for professionals who demand reliability and efficiency, this **Type 12, left-hand hinged, 2-door enclosure** measures 2200x1200x400mm and is finished in a durable light gray steel, making it ideal for harsh environments where protection against dust, dirt, and incidental contact is critical. As part of nVent’s trusted ProLine G2 series, this package simplifies the integration of major-brand disconnect switches and circuit breakers, eliminating the need for custom fabrication and reducing installation time by up to 40% compared to field-built solutions. At the heart of this package is a **hinged disconnect mullion** that provides unobstructed access to the interior, allowing technicians to mount components on the **Full Mounting Subpanel (Mounting Plate)** with ease. The **flush swing handle with defeater** operates a **3-point latch system** on the disconnect door, ensuring a secure seal while enabling quick access when maintenance is required. Interlocking between the primary door and disconnect mullion enhances safety by preventing accidental exposure to live components during servicing. Side covers are included, providing additional protection and compliance with NEMA Type 12 standards for indoor use in industrial settings. This **ProLine G2 Disconnect Package** is engineered for a wide range of applications, including **motor control centers, HVAC systems, pump stations, and manufacturing equipment**, where reliable power isolation is essential. Its **light gray steel construction** resists corrosion and withstands mechanical stress, making it suitable for facilities in food processing, pharmaceuticals, automotive, and general industrial environments. The **left-hand (LH) configuration** and **2-door design** offer flexibility for space-constrained installations, while the **2200x1200x400mm dimensions** provide ample room for medium to large disconnect switches and supplementary components. Professionals choose nVent for its **proven performance, global compliance, and commitment to innovation**. The ProLine G2 series is backed by decades of expertise in electrical enclosure design, ensuring compatibility with industry-leading disconnect switches and circuit breakers from manufacturers like Eaton, ABB, and Schneider Electric. Installation is streamlined with pre-drilled mounting holes and integrated cable entry points, reducing downtime and labor costs. For facilities prioritizing **safety, durability, and ease of maintenance**, the **nVent ProLine G2 Disconnect Package (P2KDL22124)** is a trusted solution that meets the demands of modern industrial operations. Whether upgrading existing systems or outfitting new construction, this package delivers a **complete, code-compliant solution** that aligns with NEC, UL, and IEC standards. Its **modular design** allows for future expansions, such as adding additional doors or integrating monitoring accessories, ensuring long-term adaptability. With nVent’s reputation for quality and support, customers gain peace of mind knowing their electrical infrastructure is protected by a product built to last.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
15.94
Depth
405
Door Quantity
2
Finish
Powder Coated
Height
86.69
Height
2,202
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
47
Max Subpanel Size
2106 x 1128 mm
Max Subpanel Size
82.9 x 44.4 in
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
2200x1200x400 mm
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
545 lb
Width
47.54
Width
1,208
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths available.

What is the maximum load capacity for the mobile base?

The mobile base supports a load-bearing capacity of 1000 lb. (453.6 kg).

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models, accommodating heavier electronics.

What type ratings are available for the ProLine G2?

The ProLine G2 is available in Type 12 and Type 3R ratings.

What safety features are included with the ProLine G2?

Safety features include disconnect doors, mechanical and electrical interlocks, and anti-tip brackets.

What options are available for cable management?

Cable management options include cable entry cabinets, vertical tie-downs, and various cable management accessories.

What are the EMC options available?

EMC options are available for various components, including frames, covers, and tops to ensure electromagnetic compatibility.

What is the purpose of the mechanical interlock?

The mechanical interlock prevents secondary doors from opening until the primary door is opened and the disconnect switch is thrown.

How to Install the P2KDL22124 PROLINE G2 Enclosure

Installation guide for mounting the P2KDL22124 PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Wrench set

Supplies needed:

Mounting hardware, Gasket, Door seals

  1. Prepare the mounting location

    Select a suitable location for the enclosure. Ensure the mounting surface is level and can support the weight of the enclosure. Use a measuring tape to mark the mounting hole locations.

  2. Mount the enclosure

    Drill pilot holes at the marked locations. Secure the P2KDL22124 enclosure to the mounting surface using appropriate mounting hardware. Verify that the enclosure is level and firmly attached.

  3. Install gaskets and seals

    Apply the provided gasket to the enclosure door or frame according to the instructions. Ensure a proper seal to maintain environmental protection. Attach any door seals as required.

  4. Install internal components

    Mount any internal sub-panels, rails, or components within the enclosure as per your system design. Refer to the enclosure's specific layout and component requirements.

  5. Wire the enclosure

    Route and connect all necessary power, control, and signal wiring to the appropriate terminals or devices within the enclosure. Follow all electrical codes and safety precautions. Consult the wiring diagram for your specific configuration.

  6. Final inspection and closure

    Perform a final inspection of all installations, wiring, and seals. Close and secure the enclosure door. Ensure all latches or locking mechanisms are properly engaged.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.