nVent P2KDL2088 - ProLine G2 Disconnect Package Type 12 LH 1Dr, 2000x800x800, Lt Gray, Steel
nVent

P2KDL2088

UPC: 783510346935


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Disconnect Package (SKU: P2KDL2088) is a pre-engineered, ready-to-install Type 12 enclosure designed for industrial and commercial electrical disconnect solutions. Engineered for durability and ease of installation, this left-hand, single-door package measures 2000x800x800 mm and features a lightweight yet robust steel construction in a light gray finish, ensuring corrosion resistance and long-term performance in demanding environments. Designed for flange-mount applications, the ProLine G2 Disconnect Package simplifies the integration of major-brand disconnect switches and circuit breakers, eliminating the need for custom fabrication. The hinged disconnect mullion provides unobstructed access to the interior, while the full mounting subpanel (mounting plate) maximizes space utilization for components. A flush swing handle with a defeater mechanism operates a 3-point latch system on the disconnect door, ensuring secure closure and safety compliance. Interlocking between the primary door and disconnect mullion enhances operational integrity, preventing accidental access during maintenance or operation. This package includes side covers for added protection and compliance with NEMA Type 12 standards, which are critical for safeguarding electrical components against dust, dirt, and non-corrosive liquids. The Type 12 rating makes it ideal for use in manufacturing plants, food processing facilities, automotive assembly lines, and other industrial settings where environmental protection is essential. The light gray finish not only meets aesthetic requirements but also reduces heat absorption, contributing to cooler internal operating temperatures. Professionals in electrical contracting, industrial maintenance, and facility management rely on nVent’s ProLine G2 series for its reliability, modularity, and compliance with industry standards. The ProLine G2 Disconnect Packages are part of nVent’s trusted portfolio of electrical enclosures, known for innovation, durability, and adherence to UL and NEMA certifications. Whether upgrading existing systems or designing new installations, this disconnect package offers a cost-effective, time-saving solution that ensures safety, performance, and compliance with minimal assembly required. For applications requiring a robust, off-the-shelf disconnect solution, the ProLine G2 is a premier choice.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
31.5
Depth
800
Door Quantity
1
Finish
Powder Coated
Height
78.7
Height
2,000
Material
Steel
Material
Mild Steel
Max Rack Mount Unit
42
Max Subpanel Size
1906x728 mm
Max Subpanel Size
75x28.7 in
Mounting Type
Flange-mount
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
2000x800x800 mm
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
325 lb
Width
31.5
Width
800
Package Dimensions (L x W x H)
78.8 IN x 31.8 IN x 31.7 IN
Package Dimensions (L x W x H)
200.152 cm x 80.772 cm x 80.518 cm
Package Weight (Imperial)
325.000 L
Package Weight (Metric)
147.420 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom solution.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames, covers, and doors.

How do I install the internal components?

Internal components can be mounted using grid straps and various mounting brackets provided.

How to Install the P2K1688 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1688 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1688 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Use wire strippers to prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for your application. Save the settings before exiting.

  5. Calibrate the controller

    Follow the calibration procedure as outlined in the user manual to ensure the controller operates within the desired specifications.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.