Contact for Pricing
Overview
- 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
- Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
- Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
- Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
- Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
- Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
- A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
- Door bar system on all doors (not on disconnect mullion)
- Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
- Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
Specifications
Application | Arc Flash Safety; Controls and Drives |
Color | Light Gray |
Color Code | RAL 7035 |
Depth | 19.88 |
Depth | 505 |
Door Quantity | 1 |
Finish | Powder Coated |
Height | 78.82 |
Height | 2,002 |
Material | Mild Steel |
Material | Steel |
Max Rack Mount Unit | 42 |
Max Subpanel Size | 1906 x 928 mm |
Max Subpanel Size | 75.0 x 36.5 in |
Mounting Type | Left Hinged Door |
Nema Rating | Type 12 |
Product Family | ProLine |
Series | ProLine G2 |
Size | 2000x1000x500 mm |
Thickness | 1.9 mm |
Thickness | 14 ga |
Type | Mild Steel Modular Industrial Disconnect Enclosures |
Weight | 485 lb |
Width | 39.67 |
Width | 1,008 |
Package Dimensions (L x W x H) | 46.75 IN x 28 IN x 80 IN |
Package Dimensions (L x W x H) | 118.745 cm x 71.12 cm x 203.2 cm |
Package Weight (Imperial) | 485.000 L |
Package Weight (Metric) | 219.996 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyFrequently Asked Questions
What are the available frame sizes for ProLine G2?
Frame heights range from 600 mm to 2200 mm, with various widths and depths.
How can I contact nVent for configuration help?
You can contact nVent via email at [email protected] or call 763 422 2211.
What is the load rating of the ProLine G2 frame?
The ProLine G2 frame has a 15% higher load rating than the competition.
What type ratings are available for ProLine G2?
ProLine G2 is available in Type 12 and Type 3R ratings.
Can I customize the ProLine G2 enclosure?
Yes, ProLine G2 can be customized using a comprehensive set of standard components and accessories.
What is the weight capacity of the mobile base?
The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).
What materials are used in the ProLine G2 frame?
The frame is made of 12 gauge (2.5 mm) roll-formed steel.
Are there EMC options available for ProLine G2?
Yes, EMC options are available for various components of the ProLine G2.
What safety features are included with ProLine G2?
Safety features include mechanical and electrical interlocks, as well as tamperproof hardware options.
What types of doors are available for ProLine G2?
Available door types include solid, window, perforated, and overlapping double doors.
How to Install the P2K1688 Controller
This guide provides step-by-step instructions for installing and configuring the P2K1688 Controller for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the P2K1688 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the power supply
Use wire strippers to prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.
- Verify connections
Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.
- Configure the controller settings
Access the controller's configuration interface and input the necessary parameters for your application. Save the settings before exiting.
- Calibrate the controller
Follow the calibration procedure as outlined in the user manual to ensure the controller operates within the desired specifications.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.