nVent P2KDL18106 - ProLine G2 Disconnect Package Type 12 LH 1Dr, 1800x1000x600, Lt Gray, Steel
nVent

P2KDL18106

UPC: 783510321239


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Disconnect Package (SKU: P2KDL18106) represents a superior solution for creating robust, flange-mount disconnect switch and circuit breaker installations. Engineered by nVent, a trusted leader in electrical enclosure solutions, this package delivers comprehensive functionality and exceptional ease of use for demanding industrial environments. Designed to accommodate major brands of disconnect switches and circuit breakers, the ProLine G2 simplifies the assembly process, reducing installation time and potential for error. At the core of this disconnect package is its intelligent design focused on accessibility and security. The hinged disconnect mullion is a standout feature, providing unobstructed access to the enclosure's interior. This allows for efficient wiring, maintenance, and component adjustments without compromising the integrity of the disconnect mechanism. Furthermore, the mullion ensures maximum access to the Full Mounting Subpanel (Mounting Plate), facilitating the secure and precise installation of your chosen disconnect switch or circuit breaker. Security is paramount in industrial applications, and the ProLine G2 excels in this regard. A flush swing handle, equipped with a defeater mechanism, operates an internal 3-point latch system on the disconnect door. This robust latching mechanism ensures the disconnect door remains securely closed, protecting personnel and equipment. The handle also latches directly to the disconnect mullion, further reinforcing the enclosure's security. For added safety, interlocking is seamlessly integrated from the primary enclosure door to the disconnect mullion, preventing accidental operation of the disconnect when the main enclosure is accessed. This ProLine G2 Disconnect Package includes essential side covers, contributing to a complete and finished installation. Constructed from durable steel and finished in a light gray powder coating, it offers excellent resistance to corrosion and abrasion, ensuring longevity even in harsh industrial settings. The generous dimensions of 1800x1000x600mm provide ample space for a wide range of disconnect switch and circuit breaker configurations, making it a versatile choice for various applications. Key features of the nVent ProLine G2 Disconnect Package include: * **Versatile Compatibility:** Designed to integrate seamlessly with major brands of disconnect switches and circuit breakers. * **Enhanced Accessibility:** Hinged disconnect mullion offers unobstructed interior access for installation and maintenance. * **Robust Security:** Flush swing handle with defeater operates a 3-point latch system on the disconnect door. * **Integrated Safety:** Interlocking mechanism between the primary door and disconnect mullion prevents unauthorized access. * **Durable Construction:** Made from high-quality steel with a protective light gray finish for long-term performance. * **Complete Solution:** Includes side covers for a finished and protected installation. Ideal for applications requiring reliable power control and isolation, such as motor control centers, power distribution systems, and manufacturing automation, the nVent ProLine G2 Disconnect Package (SKU: P2KDL18106) is manufactured in the USA, ensuring adherence to stringent quality standards. Its Type 12 rating signifies its suitability for indoor use where protection against dust, falling dirt, and dripping or light-raising water is required. Professionals seeking a dependable, user-friendly, and secure disconnect enclosure solution will find the ProLine G2 to be an invaluable asset.
  • 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
  • Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
  • Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
  • Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
  • A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
  • Door bar system on all doors (not on disconnect mullion)
  • Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
  • Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant

Specifications

Application
Arc Flash Safety; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
1
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Max Rack Mount Unit
38
Max Subpanel Size
1706 x 928 mm
Max Subpanel Size
67.2 x 36.5 in
Product Family
ProLine
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Modular Industrial Disconnect Enclosures
Weight
190 lb
Width
39.67
Width
1,008
Package Dimensions (L x W x H)
42 IN x 31 IN x 81 IN
Package Dimensions (L x W x H)
106.68 cm x 78.74 cm x 205.74 cm
Package Weight (Imperial)
462.000 L
Package Weight (Metric)
209.563 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

How can I contact nVent for support?

You can contact nVent customer service via email at [email protected] or call 763 422 2211.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than competitors, allowing for heavier electronics installation.

What is the maximum load capacity for mobile bases?

The mobile base supports a load-bearing capacity of 1000 lb (453.6 kg).

What types of doors are available for ProLine G2?

Available door types include solid doors, window doors, perforated doors, and overlapping double doors.

What are the available frame sizes for ProLine G2?

ProLine G2 frames are available in heights from 600 mm to 2200 mm and widths from 400 mm to 1200 mm.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, disconnect doors, and optional anti-tip brackets.

What is the purpose of the grounding bar system?

The grounding bar system provides a common point for grounding equipment, enhancing safety and compliance.

What accessories are available for cable management?

Cable management accessories include cable entry cabinets, vertical tie-downs, and wire management rails.

What is the weight capacity of the subpanel?

The subpanel can hold greater than 45% more weight compared to previous models, accommodating heavier electronics.

How to Install the P2KDL18106 Controller

This guide provides step-by-step instructions for installing and configuring the P2KDL18106 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2KDL18106 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated input terminals on the controller. Verify that the connections are secure.

  3. Configure the controller settings

    Power on the controller and use the configuration software to set the desired parameters. Follow the on-screen instructions to complete the setup.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure outlined in the user manual. Ensure all readings are within the specified range.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.