Overview
- 12 gauge (2.5mm), roll-formed steel frame with welded steel corners and hybrid frame profile for superior performance under load
- Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
- Disconnect Frames >1000 mm include two removable center uprights (front and rear) which are offset 100 mm from the center of the frame
- Standard right- or left-hand provision will accept the following types of flange-mounted disconnect devices: Allen-Bradley (Bulletin 1494V - disconnect switches with flange-mounted, variable-depth operating mechanisms and Bulletin 1494V flange-mounted var
- Right-hand disconnects have the mullion on the right, and door(s) hinged on the left; left hand disconnects have the mullion on the left, and door(s) hinged on the right; mullion door is opened via two quarter-turn cams
- Two-door disconnect packages have a removable center upright in the front, and both doors swing in the same direction (not overlapping)
- A low-profile flush swing handle with key lock (other options available) operates an internal 3-point latch system on the door; Door bar system on all doors (not on disconnect mullion)
- Door bar system on all doors (not on disconnect mullion)
- Integrated mechanical interlock system from the door(s) to the disconnect mullion; Interlock must be defeated to unlock either door: the primary door must be in the open position to open the secondary door, and the primary door must be in the open positio
- Seamless polyurethane gasket provides a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
Specifications
Application | Arc Flash Safety; Controls and Drives |
Color | Light Gray |
Color | Lt Gray |
Color Code | RAL 7035 |
Depth | 23.82 |
Depth | 605 |
Door Quantity | 2 |
Finish | Powder Coated |
Height | 63.07 |
Height | 1,602 |
Material | Steel |
Material | Mild Steel |
Max Rack Mount Unit | 33 |
Max Subpanel Size | 59.3 x 44.4 in |
Max Subpanel Size | 1506 x 1128 mm |
Nema Rating | Type 12 |
Product Family | ProLine |
Series | ProLine G2 |
Size | 1600x1200x600 mm |
Thickness | 1.9 mm |
Thickness | 14 ga |
Type | Mild Steel Modular Industrial Disconnect Enclosures |
Weight | 190 lb |
Width | 47.56 |
Width | 1,208 |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackFrequently Asked Questions
What is the load rating of the ProLine G2 frame?
The ProLine G2 frame has a 15% higher load rating than the competition.
What safety features are included with the ProLine G2?
Safety features include mechanical and electrical interlocks, disconnect doors, and anti-tip brackets.
How can I contact nVent for support?
You can contact nVent via email at [email protected] or call their USA or international numbers provided in the handbook.
What types of applications does ProLine G2 support?
ProLine G2 is designed for industrial environments and can handle various applications, including Type 3R and Seismic applications.
What are the available frame dimensions?
Frames are available in heights of 600mm to 2200mm and widths of 400mm to 1200mm.
What is the maximum load capacity for casters?
The post-type casters support a maximum load of 1000 lb (453.6 kg) when installed.
What materials are the ProLine G2 frames made from?
The frames are constructed from 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.
What is the maximum weight the subpanel can hold?
The subpanel can hold greater than 45% more weight than previous models, allowing for heavier electronics.
How can I customize my ProLine G2 enclosure?
You can customize your enclosure using a comprehensive set of standard components and accessories available in the handbook.
What is the purpose of the vented gland plate?
The vented gland plate allows for passive cooling of electronics while maintaining a NEMA 12 rating.
How to Install the P2K1686 Controller
This guide provides step-by-step instructions for installing and configuring the P2K1686 Controller.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors
- Mount the controller
Secure the P2K1686 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the power supply
Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure the connections are secure to prevent any power loss.
- Verify the connections
Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.
- Configure the controller settings
Access the controller's configuration interface and input the necessary parameters as per your system requirements. Save the settings once completed.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure the controller operates within the desired parameters. Make adjustments as necessary.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.