Overview

The nVent ProLine G2 Industrial Package (SKU: P2K688) is a pre-engineered, Type 12 enclosure solution designed for industrial electrical and automation installations. This ready-to-use package includes a robust 12-gauge steel frame, solid door with key lock, solid top and rear cover, full mounting subpanel, gland plate, and four lifting eyes. Measuring 600x800x800 mm (HxWxD) with a light gray finish, it provides ample space for control systems and sensitive electronics. Engineered for Type 12 applications, it offers protection against dust and non-corrosive liquids, suitable for manufacturing and pharmaceutical facilities. The enclosure meets UL 508A Listed, NEMA/EEMAC Type 12, and CSA Type 12 standards, with IP55 rating per IEC 60529. Features include a smooth glide latching system and a galvanized Duro-Stand gland plate. This unified package simplifies procurement and installation, reducing project timelines.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
31.69
Depth
805
Door Quantity
1
Finish
Powder Coated
Height
23.7
Height
602
Material
Mild Steel
Max Rack Mount Unit
8
Max Subpanel Size
19.9 x 28.7 in
Max Subpanel Size
506 x 728 mm
Product Family
ProLine
Type
Mild Steel Modular Industrial Enclosures
Weight
199 lb
Width
31.8
Width
808
Package Dimensions (L x W x H)
36 IN x 35 IN x 33.5 IN
Package Dimensions (L x W x H)
91.44 cm x 88.9 cm x 85.09 cm
Package Weight (Imperial)
199.000 L
Package Weight (Metric)
90.266 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum load capacity for casters?

Casters can support a maximum load of 1000 lb (453.6 kg).

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What safety features does the ProLine G2 include?

Safety features include disconnect doors, mechanical interlocks, and electrical interlocks.

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I configure my ProLine G2 enclosure?

Use the configuration handbook to select components and send it to your nVent representative.

What is the purpose of the mechanical interlock?

The mechanical interlock prevents secondary doors from opening until the primary door is opened.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames and covers.

How to Install the P2K688 PROLINE G2 Enclosure

Installation guide for mounting and wiring the P2K688 PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Drill, Level, Measuring tape, Pliers, Screwdriver, Wire strippers

Supplies needed:

Mounting hardware, Wire connectors, Grounding lug, Gasket

  1. Prepare the enclosure

    Unpack the P2K688 PROLINE G2 enclosure and inspect for any damage. Ensure all components are present. Install the gasket around the door opening according to the gasket instructions.

  2. Mount the enclosure

    Determine the mounting location. Use a level and measuring tape to mark the mounting hole positions. Drill pilot holes if necessary. Secure the enclosure using appropriate mounting hardware. Refer to the datasheet for specific mounting instructions and load ratings.

  3. Install internal components

    Install any internal mounting plates, subpanels, or component brackets as required. Ensure all components are securely fastened. Refer to the enclosure's specific configuration for component placement.

  4. Wire the enclosure

    Plan the wire routing. Install wire management accessories such as cable ties or clamps. Connect power and control wiring according to the electrical schematics. Ensure all connections are tight and properly insulated. Use appropriate wire connectors and grounding lugs. Verify wire sizes and types against the nameplate or datasheet.

  5. Ground the enclosure

    Connect the grounding conductor to the enclosure's grounding stud using a grounding lug. Ensure a secure and low-resistance connection. Refer to local electrical codes for grounding requirements.

  6. Final checks and door closure

    Double-check all wiring connections for security and correctness. Ensure no tools or debris are left inside the enclosure. Close and latch the enclosure door securely. Verify the door is properly sealed by the gasket.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.