Authorized nVent Distributor
nVent P2K664E - ProLine G2 Industrial Packages Type 12 E-Cnfg, 600x600x400, Lt Gray, Steel

nVent P2K664E ProLine G2 Industrial Packages Type 12 E-Cnfg, 600x600x400, Lt Gray, Steel

UPC: 783510320959


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 Type 12 Industrial Enclosure Package (SKU: P2K664E) delivers a complete, ready-to-deploy solution for protecting sensitive electrical and electronic components in demanding industrial environments. Designed by nVent, a global leader in thermal management and electrical protection solutions, this pre-engineered enclosure package eliminates the complexity of sourcing individual components by integrating a rugged steel frame, solid door with key lock, solid top and rear covers, full mounting subpanel, gland plate, and four lifting eyes into a single part number. The 600x600x400mm (23.6x23.6x15.7in) footprint provides ample internal space for control panels, PLCs, drives, and other automation hardware while maintaining a compact footprint ideal for tight installation spaces. The light gray powder-coated steel construction ensures durability against corrosion, impact, and environmental contaminants, meeting NEMA Type 12 standards for protection against dust, dirt, and non-corrosive liquids. Engineered for flexibility and scalability, the ProLine G2 package supports modular expansion through side covers (sold separately) for baying or joining applications, enabling seamless integration into larger control systems. The full mounting subpanel accommodates standard 19-inch rack-mount equipment up to 33 rack units, while the gland plate simplifies cable entry management without compromising enclosure integrity. The solid door features a double-bit lock for secure access control, and the four integrated lifting eyes facilitate safe handling during installation or relocation. With a maximum subpanel size of 528x528mm (20.8x20.8in), this enclosure is optimized for mid-sized control applications in manufacturing, automation, and process industries. Industries such as food and beverage processing, pharmaceuticals, automotive manufacturing, and water/wastewater treatment rely on nVent ProLine G2 enclosures to safeguard critical control systems from harsh conditions. The Type 12 rating ensures compliance with stringent industrial hygiene and safety standards, making it suitable for washdown environments where cleanliness and equipment protection are paramount. Installation is streamlined thanks to the pre-drilled mounting holes and modular design, reducing downtime and labor costs compared to custom-fabricated solutions. nVent’s reputation for innovation and reliability—backed by decades of expertise in thermal and electrical protection—positions the ProLine G2 as a trusted choice for engineers and system integrators seeking durable, code-compliant enclosures. Whether deployed in standalone applications or as part of a larger distributed control system, this enclosure package delivers performance, compliance, and peace of mind. For projects requiring Type 12 protection with minimal assembly, the P2K664E is the efficient, out-of-the-box solution.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
405 mm
Depth
15.94 in
Depth
405
Door Quantity
1-1
Door Quantity
1
Finish
Powder Coated
Height
602 mm
Height
23.7 in
Height
602
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
8
Max Subpanel Size
19.9 x 20.8 in
Max Subpanel Size
506 x 528 mm
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Series
ProLine G2 Industrial Packages
Size
600x600x400
Type
Mild Steel Modular Industrial Enclosures
Width
608 mm
Width
608
Width
23.92 in
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the available frame heights for ProLine G2?

Available frame heights include 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, and 2200 mm.

What is the weight capacity of the pull-out shelf?

The pull-out shelf has a load rating of 110 lbs. (50 kg).

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum load capacity of the mobile base?

The mobile base provides a load-bearing capacity of 1000 lb. (453.6 kg).

What is the purpose of the mechanical interlock?

The mechanical interlock prevents secondary doors from opening until the primary door is opened.

What options are available for cable management?

Options include cable entry cabinets, vertical tie-downs, and wire management rails.

What is the purpose of the ground wire kit?

The ground wire kit allows the enclosure to be grounded to VDE specifications.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What types of doors are available for the ProLine G2?

Available door types include solid, window, perforated, and overlapping double doors.

How can I ensure environmental integrity for the enclosure?

Use options like foam-in-place gaskets and sealed bases to maintain environmental integrity.

How to Install the P2K664E PROLINE G2 Enclosure

Installation guide for mounting and securing the P2K664E PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Pliers, Wire cutters, Wire strippers

Supplies needed:

Mounting hardware (screws, anchors), Wire connectors, Gasket sealant (if applicable)

  1. Select Mounting Location

    Choose a suitable location for the enclosure. Ensure the mounting surface is flat, stable, and can support the weight of the enclosure and its contents. Consider environmental factors and accessibility for maintenance. Refer to the datasheet for specific environmental ratings and weight information.

  2. Prepare Mounting Surface

    Using a measuring tape and level, mark the desired mounting points on the surface. Drill pilot holes if necessary, and install appropriate anchors if mounting to a masonry or drywall surface. Ensure the mounting points are aligned and level.

  3. Mount the Enclosure

    Position the P2K664E enclosure against the prepared mounting surface, aligning the mounting holes on the enclosure with the marked points or anchors. Secure the enclosure using appropriate mounting hardware (screws, bolts). Ensure the enclosure is firmly attached and level. For wall-mount enclosures, ensure the door opens in the correct direction and can be secured.

  4. Install Gasket and Sealant (If Applicable)

    If your enclosure came with a gasket, ensure it is properly seated in the groove around the door or frame to maintain environmental protection. If required by the environment, apply gasket sealant according to its manufacturer's instructions.

  5. Prepare for Wiring

    Identify the planned locations for cable entry. If knockouts are present, remove them using appropriate tools (e.g., knockout punch). Install cable glands or conduit fittings as needed to ensure a secure and environmentally sealed connection point for your wiring. Refer to the enclosure's specifications for maximum wire fill and conduit size limitations.

  6. Wire the Enclosure Components

    Route your electrical wiring into the enclosure through the prepared entry points. Connect the wires to the appropriate terminals, devices, or components within the enclosure according to your system's design and electrical codes. Use wire cutters and strippers as needed. Ensure all connections are secure and properly insulated. Refer to the component datasheets for specific wiring instructions and terminal layouts. Verify voltage and current ratings are within the specified limits for all components.

  7. Final Inspection and Closure

    Visually inspect all wiring and connections to ensure they are correct, secure, and properly insulated. Check that no tools or debris are left inside the enclosure. Close and secure the enclosure door, ensuring the latch or locking mechanism engages properly. If applicable, test the door seal.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.