Authorized nVent Distributor
nVent P2K2266HF - PROLINE G2 Industrial Package, Single Door, Type 12, EMC, 2200x600x600mm, Conductive, Steel

nVent P2K2266HF PROLINE G2 Industrial Package, Single Door, Type 12, EMC, 2200x600x600mm, Conductive…

UPC: 783510320775


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent PROLINE G2 Industrial Package (SKU: P2K2266HF) is a pre-engineered, Type 12-rated enclosure designed for harsh industrial environments. This single-door package measures 2200mm (H) x 600mm (W) x 600mm (D) and is constructed from durable conductive steel for reliable grounding and EMI shielding. The package includes a frame, solid door with key lock, solid top and rear covers, full mounting subpanel, gland plate, and four lifting eyes for easy handling. Side covers are available separately for baying applications. With a maximum subpanel capacity of 2106x528mm, this enclosure accommodates industrial control systems, electrical components, and automation equipment. Ideal for manufacturing plants, utilities, and data centers requiring Type 12-rated EMC protection.
  • Type 12/NEMA 12 rated for dust, dirt, and light splashing protection
  • EMC-compliant conductive steel construction for EMI shielding
  • 2200x600x600mm dimensions with 2106x528mm max subpanel capacity
  • Includes frame, door with key lock, top/rear covers, gland plate, and lifting eyes

Specifications

Material
Steel
Nema Rating
Type 12
Series
ProLine G2
Size
2200x600x600mm
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
94 CFM Filter Fan, 115V N12 - Lt. Gray

PF42500T12LG

94 CFM Filter Fan, 115V N12 - Lt. Gray
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2K2266HF PROLINE G2 Enclosure

Installation guide for mounting and wiring the P2K2266HF PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Drill, Level, Measuring tape, Pliers, Screwdriver, Wire strippers

Supplies needed:

Mounting hardware, Wire connectors, Grounding lug, Gasket

  1. Prepare the enclosure

    Unpack the P2K2266HF PROLINE G2 enclosure and inspect for any damage. Ensure all components are present. Install the gasket around the door opening according to the gasket instructions.

  2. Mount the enclosure

    Determine the mounting location. Use a level and measuring tape to mark the mounting hole positions. Drill pilot holes if necessary. Secure the enclosure using appropriate mounting hardware. Refer to the datasheet for specific mounting instructions and load ratings.

  3. Install internal components

    Install any internal mounting plates, subpanels, or component brackets as required. Ensure all components are securely fastened. Refer to the enclosure's specific configuration for component placement.

  4. Wire the enclosure

    Plan the wire routing. Install wire management accessories such as cable ties or clamps. Connect power and control wiring according to the electrical schematics. Ensure all connections are tight and properly insulated. Use appropriate wire connectors and grounding lugs. Verify wire sizes and types against the nameplate or datasheet.

  5. Ground the enclosure

    Connect the grounding conductor to the enclosure's grounding stud using a grounding lug. Ensure a secure and low-resistance connection. Refer to local electrical codes for grounding requirements.

  6. Final checks and door closure

    Double-check all wiring connections for security and correctness. Ensure no tools or debris are left inside the enclosure. Close and latch the enclosure door securely. Verify the door is properly sealed by the gasket.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.