nVent ProLine G2 Type 12 E-Cnfg Industrial Package (SKU: P2K2046E) is a pre-engineered enclosure for industrial electrical/automation installations. Dimensions: 2000x400x600mm (78.7x15.7x23.6in). 12-gauge (2.5mm) roll-formed steel frame with welded corners and hybrid profile. Light gray powder-coated finish for corrosion resistance. Includes solid door with handle/key lock, solid top/rear cover, full mounting subpanel with EZ-Load Glide Blocks, galvanized gland plate, and four integrated lifting eyes. Side covers sold separately for baying. Mounting subpanel supports five loading options (vertical front/side/rear, horizontal front/rear) and is depth-adjustable with back-to-back configuration. Enclosures under 1200mm width use 4 sets of glide blocks; larger units use 8 sets. Two grounding studs per door. Pre-drilled mounting holes and integrated lifting eyes simplify installation. Suitable for automation, HVAC, power distribution, telecommunications, and renewable energy applications. Supports mid-to-large-scale control panels, motor drives, or industrial PCs with ample wiring space.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Power Distribution; Controls and Drives
Application
Controls and Drives;Power Distribution
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Depth
23.82 in
Depth
605 mm
Depth
605
Door Quantity
1-1
Door Quantity
1
Finish
Powder Coated
Finish
Powder Coating
Height
78.82 in
Height
2,002 mm
Height
2,002
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
42
Max Subpanel Size
1906 x 328 mm
Max Subpanel Size
75.0 x 12.9 in
Max Subpanel Size
23.03 x 44.49 in
Mounting Type
Integrated lifting eyes, pre-drilled mounting holes
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
2000x400x600 mm
Type
Mild Steel Modular Industrial Enclosures
Width
408
Width
408 mm
Width
16.05 in
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What are the available frame heights for ProLine G2?

Available frame heights include 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, and 2200 mm.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom enclosure suited to your application.

How do I contact nVent for support?

You can contact nVent at [email protected] or call HOFFMAN-USA at 763 422 2211.

What materials are used in the ProLine G2 frame?

The frame is made from 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What is the maximum load capacity for mobile bases?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What types of doors are available for ProLine G2?

Available door types include solid doors, window doors, perforated doors, and overlapping double doors.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models, accommodating heavier electronics.

What is the purpose of the mechanical interlock?

The mechanical interlock prevents secondary doors from opening until the primary door is opened and the disconnect switch is thrown.

How to Install the P2K2046E PROLINE G2

Installation guide for mounting the P2K2046E PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Level, Measuring tape

Supplies needed:

Mounting hardware, Gasket material

  1. Plan the enclosure location

    Determine the optimal location for the P2K2046E PROLINE G2 enclosure, considering accessibility, environmental factors, and required clearances. Refer to the datasheet for specific dimensions and mounting requirements.

  2. Prepare the mounting surface

    Ensure the mounting surface is clean, level, and capable of supporting the weight of the enclosure and its contents. Mark the mounting hole locations accurately using a measuring tape and level.

  3. Drill mounting holes

    Drill the mounting holes in the prepared surface according to the marked locations. Use appropriate drill bits for the surface material. Clean any debris from the holes.

  4. Mount the enclosure

    Position the P2K2046E PROLINE G2 enclosure against the mounting surface, aligning the enclosure's mounting holes with the drilled holes. Secure the enclosure using appropriate mounting hardware. Ensure the enclosure is firmly attached and level.

  5. Install gasket and close the door

    If applicable, install the gasket material around the door frame to ensure a proper seal. Close and secure the enclosure door. Verify that the door latches properly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.