Authorized nVent Distributor
nVent P2K18104 - ProLine G2 Industrial Packages Type 12, 1800x1000x400, Lt Gray, Steel

nVent P2K18104 ProLine G2 Industrial Packages Type 12, 1800x1000x400, Lt Gray, Steel

UPC: 783510319861


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

nVent ProLine G2 Industrial Package (SKU: P2K18104) is a Type 12 enclosure solution for industrial control panels, automation systems, and power distribution. Single part number includes 12-gauge steel frame with welded corners, solid door(s) with key lock, solid top, solid rear cover, full mounting subpanel, and four lifting eyes. Dimensions: 1800x1000x400 mm (70.94x39.67x15.75 in). Light gray powder-coated finish for corrosion resistance. Type 12-rated (IP55/IEC 60529) for dust-tight and drip-proof protection in indoor environments. Door system features Smooth Glide Latching System with 3-point roller latch for secure sealing with low closure force. Single doors reversible (default left hinge); double-door versions use overlapping doors for full-width access. Mounting subpanel depth-adjustable with EZ-Load Glide Blocks supporting five loading configurations (vertical front/side/rear, horizontal front/rear). Includes galvanized gland plate and two grounding studs per door. Side covers sold separately for baying applications. Heavy-duty construction supports fully-recessed or front-mounted subpanels with back-to-back configurations. Hybrid frame profile and 25-mm DIN hole pattern for robust component mounting. Designed for manufacturing plants, processing facilities, and network infrastructure.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
15.94
Depth
405
Door Quantity
1
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
38
Max Subpanel Size
67.2 x 36.5 in
Max Subpanel Size
1706 x 928 mm
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1800x1000x400 mm
Type
Mild Steel Modular Industrial Enclosures
Weight
379 lb
Width
39.67
Width
1,008
Package Dimensions (L x W x H)
46.5 IN x 26 IN x 78 IN
Package Dimensions (L x W x H)
118.11 cm x 66.04 cm x 198.12 cm
Package Weight (Imperial)
379.000 L
Package Weight (Metric)
171.914 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the available frame heights?

Available frame heights include 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, and 2200 mm.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What safety features are included in the ProLine G2?

Safety features include mechanical and electrical interlocks to prevent unauthorized access and ensure safe operation.

What materials are used for the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What type ratings are available for the ProLine G2?

The ProLine G2 is available in Type 12 and Type 3R ratings.

What is the maximum load capacity for mobile bases?

The mobile base has a load-bearing capacity of 1000 lb (453.6 kg).

What options are available for cable management?

Options include cable entry cabinets, vertical tie-downs, and various cable management accessories.

How can I configure my ProLine G2 enclosure?

You can select components and send your configuration to an nVent HOFFMAN representative for assistance.

How do I maintain the ProLine G2 enclosure?

Regular inspections and cleaning of the enclosure and its components are recommended to ensure optimal performance.

How to Install the P2K18104 Controller

This guide provides step-by-step instructions for installing and configuring the P2K18104 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K18104 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated power input terminals on the controller. Verify the polarity is correct to avoid damage.

  3. Wire the input/output connections

    Connect the necessary input and output devices to the corresponding terminals on the controller. Ensure all connections are secure and insulated.

  4. Configure the controller settings

    Using the provided software, connect to the controller via USB or Ethernet and configure the settings according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the software to ensure accurate readings and performance. Test the system to confirm proper operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.