The nVent ProLine G2 Industrial Package (SKU: P2K1665) is a fully integrated, Type 12-rated enclosure designed to streamline industrial electrical and automation installations. This pre-engineered solution eliminates the need for separate component sourcing by bundling a robust steel frame, solid door with handle and key lock, solid top, solid rear cover, full mounting subpanel, gland plate, and four integrated lifting eyes into a single, ready-to-install package. Engineered for durability and compliance, the ProLine G2 is constructed from high-strength steel with a light gray powder-coated finish, providing superior corrosion resistance and a professional appearance suitable for harsh industrial environments. Industrial enclosures like the ProLine G2 serve as the backbone of electrical and automation systems, housing critical components such as PLCs, motor controllers, drives, and power distribution units. The Type 12 rating ensures protection against dust, falling dirt, and non-corrosive liquids, making it ideal for manufacturing plants, food and beverage facilities, pharmaceutical production, and other environments where cleanliness and equipment integrity are paramount. The 1600x600x500mm dimensions offer ample internal space for complex wiring and component layouts, while the full mounting subpanel simplifies installation by providing a pre-drilled surface for secure mounting of devices. One of the standout features of the ProLine G2 is its modularity and expandability. While the enclosure arrives fully assembled with all essential components, side covers are available separately to facilitate joining or baying applications, allowing for seamless integration into larger control system architectures. The integrated gland plate accommodates cable entry from multiple directions, reducing installation time and minimizing the risk of ingress points. The four lifting eyes ensure safe and efficient handling during transport and installation, a critical consideration for large enclosures in industrial settings. Selecting the right industrial enclosure is a critical decision that impacts system reliability, safety, and long-term maintenance costs. Professionals prioritize enclosures that meet or exceed industry standards, such as NEMA Type 12 or IP54 ratings, while also considering factors like material durability, ease of installation, and future scalability. The ProLine G2 from nVent, a trusted leader in thermal management and electrical protection solutions, is engineered to address these needs with precision. nVent’s reputation for innovation and quality is underscored by its adherence to rigorous testing protocols and certifications, ensuring that the ProLine G2 delivers consistent performance in even the most demanding applications. Whether you are outfitting a new production line, upgrading an existing control system, or designing a modular automation solution, the nVent ProLine G2 Industrial Package (P2K1665) provides a cost-effective, time-saving alternative to custom-built enclosures. Its pre-configured design reduces procurement complexity, accelerates deployment, and ensures compliance with safety and performance standards. For engineers, contractors, and facility managers seeking a reliable, high-quality enclosure solution, the ProLine G2 stands out as a smart investment in operational efficiency and system longevity.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Door Quantity
1
Finish
Powder Coated
Height
63.07
Height
1,602
Material
Mild Steel
Max Rack Mount Unit
33
Max Subpanel Size
1506 x 528 mm
Max Subpanel Size
59.3 x 20.8 in
Product Family
ProLine
Type
Mild Steel Modular Industrial Enclosures
Weight
275 lb
Width
23.92
Width
608
Package Dimensions (L x W x H)
60 IN x 30 IN x 30 IN
Package Dimensions (L x W x H)
152.4 cm x 76.2 cm x 76.2 cm
Package Weight (Imperial)
275.000 L
Package Weight (Metric)
124.740 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What safety features are included with the ProLine G2?

Safety features include mechanical and electrical interlocks, disconnect doors, and barrier panels.

What is the weight capacity of the mobile base?

The mobile base provides a load-bearing capacity of 1000 lb (453.6 kg).

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What type ratings are available for the ProLine G2?

The ProLine G2 is available in Type 12 and Type 3R ratings.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard industrial packages and various components to create a custom solution.

What is the purpose of the grounding bar system?

The grounding bar system provides a common point for grounding equipment to ensure safety.

What are the EMC options available?

EMC options are available for various components, including frames, covers, and doors.

What accessories can I add for cable management?

You can add cable entry cabinets, tie-down brackets, and wire management rails for effective cable management.

What are the available frame dimensions?

Frame heights range from 600 mm to 2200 mm, with various widths and depths available.

How to Install the P2ACU16 Controller

This guide provides step-by-step instructions for installing and configuring the P2ACU16 Controller for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2ACU16 controller to a suitable mounting surface using the provided mounting screws. Ensure it is level and securely fastened.

  2. Connect power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the P2ACU16. Ensure the connections are tight and insulated to prevent short circuits.

  3. Wire the input/output terminals

    Connect the input and output devices to the corresponding terminals on the P2ACU16. Refer to the wiring diagram for correct terminal assignments.

  4. Configure the controller settings

    Power on the P2ACU16 and access the configuration menu using the front panel buttons. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Perform a calibration of the P2ACU16 by following the on-screen instructions. Ensure all sensors and inputs are functioning correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.