nVent P2K1066 - ProLine G2 Industrial Packages Type 12, 1000x600x600, Lt Gray, Steel
nVent

P2K1066

UPC: 783510319243


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Industrial Package (SKU: P2K1066) is a pre-engineered, Type 12-rated enclosure solution designed to simplify industrial electrical and automation installations. Manufactured by nVent, a global leader in thermal management and electrical protection, this ready-to-use package eliminates the complexity of sourcing individual components, ensuring faster deployment and reduced project risk. The enclosure features a robust steel construction with a light gray powder-coated finish, providing superior corrosion resistance and durability in demanding industrial environments. The 1000x600x600mm dimensions offer ample internal space for housing control panels, drives, PLCs, or other sensitive equipment, while the Type 12 rating ensures protection against dust, falling debris, and non-corrosive liquids—ideal for manufacturing plants, food processing facilities, and harsh industrial settings. This ProLine G2 package includes a fully assembled frame, solid door with a handle and key lock, solid top and rear covers, a full mounting subpanel, gland plate, and four integrated lifting eyes for safe and efficient handling. The single part number streamlines procurement, reducing administrative overhead and minimizing the risk of missing components. Side covers, available separately, enable seamless joining or baying applications, allowing for scalable enclosure systems that grow with your operational needs. Designed for versatility, the ProLine G2 Industrial Package supports a wide range of industrial applications, from motor control centers and variable frequency drives (VFDs) to industrial automation and instrumentation panels. The enclosure’s modular design accommodates customization through optional accessories such as ventilation panels, viewing windows, or additional mounting hardware. With a maximum subpanel capacity of 1506x528mm (HxW), it provides flexibility for complex internal layouts, while the reversible door hinging and overlapping double-door options (available in larger sizes) enhance accessibility and maintenance workflows. nVent’s ProLine G2 series is engineered to meet the rigorous demands of industrial environments, where reliability and compliance are non-negotiable. The Type 12 rating ensures compliance with NEMA and UL standards, making it suitable for use in hazardous or high-dust areas. The powder-coated steel construction resists chipping, fading, and corrosion, ensuring long-term performance even in corrosive or high-moisture conditions. Additionally, the enclosure’s design facilitates easy cable entry and exit via the included gland plate, simplifying installation and reducing downtime during setup or reconfiguration. Professionals in industries such as food and beverage, pharmaceuticals, automotive manufacturing, and wastewater treatment rely on nVent’s ProLine G2 packages for their durability, compliance, and ease of integration. The single-source solution minimizes project delays by eliminating the need to coordinate multiple suppliers, while the comprehensive package ensures all critical components are accounted for from day one. Whether you’re retrofitting an existing system or deploying a new control panel, the ProLine G2 Industrial Package delivers a robust, code-compliant solution that stands up to the rigors of industrial operations. Trusted by engineers and facility managers worldwide, nVent’s ProLine G2 series is a cornerstone of reliable industrial enclosure solutions.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
1
Finish
Powder Coated
Height
39.45
Height
1,002
IP Rating
IP54
Material
Steel
Material
Mild Steel
Max Rack Mount Unit
18
Max Subpanel Size
35.7 x 20.8 in
Max Subpanel Size
906 x 528 mm
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Size
1000x600x600 mm
Type
Mild Steel Modular Industrial Enclosures
Weight
181 lb
Width
23.92
Width
608
Package Dimensions (L x W x H)
31 IN x 31 IN x 48 IN
Package Dimensions (L x W x H)
78.74 cm x 78.74 cm x 121.92 cm
Package Weight (Imperial)
181.000 L
Package Weight (Metric)
82.102 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various width and depth options.

What is the maximum load capacity for the mobile base?

The mobile base supports a load-bearing capacity of 1000 lb (453.6 kg).

Can I customize the ProLine G2 enclosure?

Yes, ProLine G2 features a comprehensive set of standard components that can be configured for custom solutions.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models, accommodating heavier electronics.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, grounding studs, and optional tamperproof hardware.

What options are available for cable management?

Options include cable entry cabinets, tie-down brackets, and various cable management accessories.

What is the purpose of the mechanical interlock?

The mechanical interlock prevents secondary doors from opening until the primary door is opened and the disconnect switch is thrown.

How to Install the P2K1066 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1066 controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1066 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated input terminals on the controller. Verify that the connections are secure.

  3. Configure initial settings

    Power on the controller and use the programming interface to configure the initial settings according to your application requirements. Refer to the user manual for specific configuration options.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.