Authorized nVent Distributor
nVent P2FD18186 - ProLine G2 Disconnect Frames, 1800x1800x600

nVent P2FD18186 ProLine G2 Disconnect Frames, 1800x1800x600

UPC: 783510318246


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 Disconnect Frame (SKU: P2FD18186) is a high-performance, modular enclosure frame designed to deliver robust protection and organization for industrial electrical disconnect systems. Engineered by nVent, a global leader in electrical and thermal management solutions, this 1800x1800x600 mm frame is part of the ProLine G2 system, enabling seamless integration with ProLine G2 Disconnect Doors and components to create tailored, compliant enclosure solutions for a wide range of applications. This disconnect frame is built to meet the rigorous demands of industrial environments, where reliability, safety, and modularity are paramount. The ProLine G2 system is widely trusted in sectors such as manufacturing, utilities, renewable energy, and commercial facilities, where standardized yet customizable enclosure solutions are essential for housing disconnect switches, circuit breakers, and other critical electrical components. The 1800x1800x600 mm dimensions provide ample space for complex configurations while maintaining a compact footprint, making it ideal for both new installations and retrofits. Key features of the ProLine G2 Disconnect Frame include its durable construction, which ensures long-term performance even in harsh conditions. The modular design allows for easy customization, enabling professionals to configure enclosures that meet specific project requirements without compromising on safety or compliance. The frame is compatible with a variety of ProLine G2 components, including doors, panels, and mounting hardware, providing flexibility in design and installation. Additionally, the frame’s robust build supports heavy-duty electrical equipment, making it suitable for high-current applications. Industries that benefit from the ProLine G2 Disconnect Frame include: - **Manufacturing**: For housing motor control centers, variable frequency drives, and other industrial equipment. - **Utilities**: In substations and power distribution centers where reliability and compliance with safety standards are critical. - **Renewable Energy**: For solar and wind power installations, where enclosures must protect sensitive electrical components from environmental factors. - **Commercial Facilities**: In data centers, hospitals, and large-scale buildings where organized, secure electrical distribution is required. Installation is streamlined thanks to the ProLine G2 system’s standardized components, which are designed for quick assembly and disassembly. This reduces downtime during maintenance or upgrades while ensuring that the enclosure remains compliant with industry regulations such as NEC, UL, and IEC standards. The frame’s construction also facilitates proper cable management, ventilation, and heat dissipation, further enhancing the longevity and performance of the enclosed equipment. nVent’s reputation for innovation and quality makes the ProLine G2 Disconnect Frame a trusted choice for professionals who require dependable, high-performance enclosure solutions. With a focus on modularity, durability, and compliance, this frame is an essential component for any industrial electrical system where safety and efficiency are priorities. Whether for new construction or system upgrades, the ProLine G2 Disconnect Frame provides the flexibility and reliability needed to meet the challenges of modern electrical infrastructure.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • RAL 7035 textured light-gray polyester powder paint finish
  • Similar in design and construction as other ProLine G2 frames, but incorporates a 100-mm offset due to the presence of a 200-mm mullion door in the disconnect door solution
  • Includes combination removable center upright/verticals in both the front and rear of the enclosure, again with a 100-mm offset
  • Disconnect specific frame is required for any enclosure solution >1000mm in width; widths 1000mm or less utilize a standard single-bay frame
  • Flange trough collar on door and side openings deflect dust and debris away from the enclosure interior
  • Integral frame channels support the full weight of the mounting subpanel
  • Accommodates 25-mm DIN standard; rectangular frame holes designed for BV-M6 fastener or metric cage nut fasteners; round frame holes accommodate M5 self-tapping screws and allow numerous grounding locations using M5 thread-forming screws

Specifications

Application
Power Distribution; Arc Flash Safety; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Material
Mild Steel
Max Rack Mount Unit
38
Max Subpanel Size
67.2 x 68.0 in
Max Subpanel Size
1706 x 1728 mm
Product Family
ProLine
Thickness
2.66 mm
Thickness
12 ga
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
545 lb
Package Dimensions (L x W x H)
36 IN x 32 IN x 78 IN
Package Dimensions (L x W x H)
91.44 cm x 81.28 cm x 198.12 cm
Package Weight (Imperial)
390.000 L
Package Weight (Metric)
176.904 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Safely Handle and Install a Hoffman Enclosure

Follow these instructions for the safe handling and installation of your Hoffman enclosure. Always prioritize safety and refer to the nameplate or datasheet for specific model information.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device, Slings with hooks or shackles, Chain or strap (3000 lb-rated)

Supplies needed:

Mounting screws, ROLL•A•LIFT™ or similar device

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and workers are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. If using a forklift, know its safe lifting capabilities and ensure it can handle the enclosure's weight and size. Always use both forks and position the enclosure far back on the forks, keeping the load against the carriage and tilting the load backwards towards the mast.

  3. Secure Enclosure for Transport

    If using a forklift, secure the enclosure to the forklift mast using a 3000 lb-rated chain or strap through the provided eye bolts. Ensure sufficient tension to prevent tipping. If using an overhead lifting device, attach rigging to eye bolts, maintaining a maximum 45° angle between lifting cables and the vertical. Use slings with adequate load-rated hooks or shackles, not ropes or cables.

  4. Move the Enclosure

    Start and stop the forklift slowly and gradually. Drive slowly with the forks as low to the ground as possible. For overhead lifting, select or adjust rigging lengths to compensate for any unequal weight distribution and support the enclosure in an upright position. Do not attempt to lift the enclosure completely off the ground if using a forklift with a clamping device.

  5. Position the Enclosure

    Carefully position the enclosure on the forks or in its final location. Ensure it is stable and does not contact fixed objects. If using a ROLL•A•LIFT™ or similar device for multi-door enclosures, place it under one end and lift that end slightly while the forklift handles the other.

  6. Final Installation Checks

    Verify that the enclosure is level, firmly installed, and all safety precautions have been followed. Re-check tension on any securing chains or straps. Refer to the nameplate or datasheet for any model-specific installation details not covered here.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.