nVent P2FC128 - ProLine G2 Cable Entry Cabinets, fits 1200x800mm, Light Gray, Steel
nVent

P2FC128

UPC: 783510330781


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent ProLine G2 Cable Entry Cabinet (P2FC128)** is a premium, side-mount steel enclosure designed for efficient cable management in industrial and commercial electrical systems. Engineered for compatibility with 1200x800mm modular enclosures, this light gray cabinet provides a secure and organized pathway for cables entering or exiting control panels, switchgear, and other electrical housings. Its full-height side opening accommodates high-density cable routing while maintaining structural integrity, making it an ideal solution for facilities requiring scalable and compliant cable infrastructure. **Key Features and Benefits:** - **Durable Steel Construction**: Built from high-quality steel, the ProLine G2 ensures long-term durability and protection against physical damage, corrosion, and environmental stressors. This robust material is essential for industrial environments where reliability is critical. - **Full-Height Side Opening**: The 1200x800mm cabinet features a full-height side opening, allowing for flexible cable entry and exit points. This design simplifies installation and maintenance, reducing downtime during system upgrades or repairs. - **Modular Compatibility**: Designed to integrate seamlessly with nVent’s ProLine G2 modular enclosure system, this cable entry cabinet supports a standardized approach to electrical infrastructure. Professionals can easily expand or reconfigure systems without compromising performance or safety. - **Versatile Closure Options**: Includes closure plates for sealing the top and bottom cable entry points, ensuring compliance with IP ratings and preventing dust, moisture, or pests from entering the enclosure. Optional solid doors or side covers provide additional protection and aesthetic flexibility. - **Light Gray Finish**: The light gray powder-coated finish offers a professional appearance while resisting chipping, fading, and chemical exposure. This finish is ideal for facilities prioritizing both functionality and visual consistency. **Industry Applications:** The ProLine G2 Cable Entry Cabinet is widely used across industries such as manufacturing, data centers, utilities, and commercial buildings. In **manufacturing plants**, it facilitates organized cable routing for machinery and automation systems, reducing clutter and improving safety. **Data centers** rely on these cabinets to manage high-density cabling for servers, switches, and power distribution units, ensuring optimal airflow and cooling efficiency. **Utilities and energy sectors** use them to protect critical control wiring in substations and renewable energy installations, where environmental resilience is paramount. **Installation and Selection Considerations:** When selecting a cable entry cabinet, professionals must evaluate the **cable volume, environmental conditions, and compliance requirements**. The ProLine G2’s side-mount design simplifies installation on existing enclosure frames, while its compatibility with closure plates ensures adaptability for varying cable diameters and entry angles. For outdoor or harsh environments, consider additional sealing or gasketing to enhance protection. **Why Choose nVent?** As a trusted leader in electrical and thermal management solutions, nVent delivers products engineered for performance, safety, and longevity. The ProLine G2 series reflects the company’s commitment to innovation, with a focus on modularity, durability, and ease of use. Backed by rigorous testing and industry certifications, nVent products are a preferred choice for professionals who demand reliability in mission-critical applications. Whether for new construction or system upgrades, the ProLine G2 Cable Entry Cabinet provides a scalable, high-quality solution for cable management challenges.
  • 14 gauge (1.75mm) mild steel
  • RAL 7035 textured light-gray polyester powder paint finish
  • Foam-in-place gasket and optional accessories to maintain environmental integrity
  • Open top and bottom of cabinet; closure plates sold separately
  • Front opening of cabinet can be closed with either solid door or cover
  • 14 gauge (1.75mm) mild steel

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1200 x 800 mm
Material
Steel
Material
Mild Steel
Mounting Type
Side Mount
Product Family
ProLine
Series
ProLine G2
Size
1200x800mm
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
175 lb
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2FC128 Controller

This guide provides step-by-step instructions for installing and configuring the P2FC128 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2FC128 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely fastened.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the P2FC128 controller. Ensure correct polarity to avoid damage.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the P2FC128 controller. Ensure the voltage matches the specifications outlined in the user manual.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters as per your application requirements. Save the settings.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.