Authorized nVent Distributor
nVent P2F2286HF - PROLINE G2 Frame, EMC, 2200x800x600mm, Conductive, Steel

nVent P2F2286HF PROLINE G2 Frame, EMC, 2200x800x600mm, Conductive, Steel

UPC: 783510317959


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent PROLINE G2 Frame (SKU: P2F2286HF)** is a high-performance, conductive steel enclosure designed to meet the rigorous demands of electromagnetic compatibility (EMC) applications in industrial and commercial environments. Engineered with precision and durability in mind, this robust frame measures 2200x800x600mm, providing ample space for housing sensitive electronic equipment while ensuring structural integrity and reliable shielding against electromagnetic interference (EMI). Constructed from high-quality, conductive steel, the PROLINE G2 Frame is built to withstand the harsh conditions of industrial settings, including telecommunications hubs, data centers, and industrial control systems. Its conductive properties enable effective EMC shielding, minimizing the risk of signal disruption and ensuring compliance with stringent electromagnetic compatibility standards. This frame is particularly well-suited for applications where sensitive electronic components—such as servers, routers, and control panels—require protection from external electromagnetic interference. The **PROLINE G2 Frame** is part of nVent’s trusted PROLINE series, a line of industrial enclosures and frames renowned for their reliability, precision engineering, and adherence to global standards. nVent, a leader in electrical and thermal management solutions, has built a reputation for delivering products that combine innovation with durability, making them a preferred choice for engineers and facility managers across industries. The conductive steel construction not only enhances EMC performance but also ensures long-term durability, reducing maintenance costs and downtime. Key applications for the **nVent PROLINE G2 Frame** include: - **Telecommunications:** Housing network equipment in data centers and telecom facilities where EMI shielding is critical for uninterrupted service. - **Industrial Control Systems:** Protecting PLCs, HMIs, and other automation components from electromagnetic interference in manufacturing plants and processing facilities. - **Power Distribution:** Safeguarding sensitive electronics in switchgear and power management systems. - **Medical Equipment:** Ensuring compliance with EMC regulations for diagnostic and monitoring devices in healthcare settings. - **Renewable Energy:** Supporting the integration of electronic components in solar inverters, wind turbine controllers, and battery management systems. Installation of the **PROLINE G2 Frame** is straightforward, thanks to its modular design and precise dimensions. The frame’s open architecture allows for easy integration with additional panels, doors, or accessories, making it a versatile solution for custom enclosures. Professionals in the field appreciate its compatibility with standard mounting hardware and its ability to accommodate various ventilation and cooling solutions, ensuring optimal performance for enclosed equipment. For engineers and procurement specialists seeking a reliable, high-performance EMC frame, the **nVent PROLINE G2 Frame (P2F2286HF)** stands out as a top-tier choice. Its combination of conductive steel construction, precise dimensions, and nVent’s legacy of quality make it an ideal solution for protecting critical electronic infrastructure in demanding environments. Whether deployed in a data center, industrial facility, or telecommunications hub, this frame delivers the performance and reliability required to maintain operational integrity in the face of electromagnetic challenges.
  • Conductive steel construction for effective EMC shielding
  • Dimensions: 2200x800x600mm for versatile equipment housing
  • Ideal for telecommunications, data centers, and industrial control systems
  • Part of nVent's trusted PROLINE series for industrial enclosures
  • Modular design for easy integration with accessories and ventilation solutions
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Safely Handle and Install a Hoffman Enclosure

Follow these instructions for the safe handling and installation of your Hoffman enclosure. Always prioritize safety and refer to the nameplate or datasheet for specific model information.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device, Slings with hooks or shackles, Chain or strap (3000 lb-rated)

Supplies needed:

Mounting screws, ROLL•A•LIFT™ or similar device

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and workers are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. If using a forklift, know its safe lifting capabilities and ensure it can handle the enclosure's weight and size. Always use both forks and position the enclosure far back on the forks, keeping the load against the carriage and tilting the load backwards towards the mast.

  3. Secure Enclosure for Transport

    If using a forklift, secure the enclosure to the forklift mast using a 3000 lb-rated chain or strap through the provided eye bolts. Ensure sufficient tension to prevent tipping. If using an overhead lifting device, attach rigging to eye bolts, maintaining a maximum 45° angle between lifting cables and the vertical. Use slings with adequate load-rated hooks or shackles, not ropes or cables.

  4. Move the Enclosure

    Start and stop the forklift slowly and gradually. Drive slowly with the forks as low to the ground as possible. For overhead lifting, select or adjust rigging lengths to compensate for any unequal weight distribution and support the enclosure in an upright position. Do not attempt to lift the enclosure completely off the ground if using a forklift with a clamping device.

  5. Position the Enclosure

    Carefully position the enclosure on the forks or in its final location. Ensure it is stable and does not contact fixed objects. If using a ROLL•A•LIFT™ or similar device for multi-door enclosures, place it under one end and lift that end slightly while the forklift handles the other.

  6. Final Installation Checks

    Verify that the enclosure is level, firmly installed, and all safety precautions have been followed. Re-check tension on any securing chains or straps. Refer to the nameplate or datasheet for any model-specific installation details not covered here.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.