nVent P2DWOG2216 - ProLine G2 Window Overlapping Double Doors, fits 2200x1600mm, Aluminum, Glass
nVent

P2DWOG2216

UPC: 783510316464


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Window Overlapping Double Doors (SKU: P2DWOG2216) represent a premium solution for industrial enclosures requiring integrated visual access and robust protection. Engineered by nVent, a leader in electrical enclosure solutions, these doors are designed to facilitate the monitoring of internal electronic equipment without compromising the integrity of the enclosure. Their clean, contemporary aesthetic complements modern industrial installations. Constructed from durable aluminum with integrated glass panels, these doors offer a clear, unobstructed view of sensitive components. The glass is safety-rated, ensuring compliance with industrial safety standards. The overlapping design of the double doors provides an enhanced seal against environmental ingress, crucial for maintaining the operational reliability of housed equipment in demanding conditions. This design also contributes to the overall structural integrity of the enclosure. A key feature of the ProLine G2 system is its versatile standard door bar system. This integrated accessory mounting solution allows for the easy attachment of various internal components, such as control panels, displays, or additional monitoring devices, streamlining installation and maintenance workflows. This adaptability makes the ProLine G2 doors suitable for a wide range of applications across diverse industries. Furthermore, the ProLine G2 doors incorporate nVent's innovative Smooth Glide latching system. This system is meticulously crafted from high-quality components, ensuring longevity and reliable operation. The timed latch action is a significant advancement, guaranteeing a solid and secure door seal with a remarkably low closure force. This feature not only enhances the sealing performance against dust, moisture, and other contaminants but also reduces wear and tear on the door and frame, contributing to a longer product lifespan and reduced maintenance requirements. The ease of operation, even with gloves, is a testament to the user-centric design. Applications for the nVent ProLine G2 Window Overlapping Double Doors are extensive, including: * Control cabinets for manufacturing automation * Telecommunications equipment enclosures * Data center infrastructure * Process control systems in chemical plants and refineries * Utility substations and power distribution * Building management systems These doors are manufactured in the USA, reflecting a commitment to quality and domestic production. The UNSPSC code 39121334 categorizes these as 'Enclosure doors and frames,' highlighting their specific function within industrial infrastructure. When selecting enclosure solutions, professionals prioritize durability, environmental protection, ease of access, and the ability to monitor internal systems. The ProLine G2 Window Overlapping Double Doors from nVent meet these critical requirements, offering a reliable and efficient solution for safeguarding valuable electronic equipment while enabling essential visual inspection.
  • Safety glass or polycarbonate (for food and beverage applications)
  • Smooth Glide latching system – for a smooth, reliable and repeatable door close over enclosure lifetime
  • Clean, contemporary design
  • Window doors available for frames up to 1000 mm wide
  • 0.25 in. (6.35 mm) thick window to provide maximum protection and viewing area
  • Standard door bar system on all window doors for easy accessories attachment
  • Low-profile Swing Handle with key lock; other options available
  • Seamless polyurethane gasket (UL component recognized) provides a water-tight, dust-tight seal against moisture and contaminants
  • Timed latch engagement to ensure top and bottom of door catch reliably
  • Durable, double-flanged latch rod and three Delrin® rollers to prevent metal-on-metal grinding

Specifications

Application
Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Door Quantity
2
Finish
Powder Coated
Fits Frame
2200x1600 mm
Material
Mild Steel
Material
Aluminum/Glass
Material
Aluminum, Glass
Product Family
ProLine
Series
ProLine G2
Size
2200x1600mm
Thickness
14 ga
Thickness
1.9 mm
Type
Safety Glass
Weight
33.2 lb
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2DWOG2216 Controller

This guide provides step-by-step instructions for installing and configuring the P2DWOG2216 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2DWOG2216 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the appropriate terminals on the controller. Verify that the connections are secure and insulated.

  3. Configure the controller settings

    Power on the controller and use the interface to navigate to the settings menu. Adjust the parameters according to your system requirements and save the configuration.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual. This may involve adjusting sensitivity settings and testing the output to ensure accurate performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.