nVent P2DWO1816 - ProLine G2 Window Overlapping Double Doors, fits 1800x1600mm, Aluminum, Polycarbonate
nVent

P2DWO1816

UPC: 783510315740


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance the visibility and accessibility of your critical electronic equipment with the nVent ProLine G2 Window Overlapping Double Doors (SKU: P2DWO1816). Designed for robust industrial environments, these doors offer a contemporary aesthetic combined with advanced functionality. The ProLine G2 series is engineered to provide clear viewing of internal components without compromising enclosure integrity, a crucial requirement in many industrial control and automation applications. Constructed from durable aluminum with high-impact polycarbonate windows, these doors are built to withstand demanding conditions. The overlapping design ensures a superior seal against environmental contaminants such as dust, moisture, and debris, protecting sensitive electronics. The clear polycarbonate material allows for easy visual inspection of equipment status, operational indicators, and potential issues, reducing the need for frequent door openings and maintaining a stable internal environment. This feature is particularly valuable in sectors like manufacturing, telecommunications, and utilities where uptime and continuous monitoring are paramount. The ProLine G2 Window Doors feature a standard door bar system, facilitating the straightforward attachment of various accessories. This modular approach allows for customization to meet specific operational needs, whether it's mounting additional control panels, diagnostic tools, or other essential equipment. The integration of these accessories is streamlined, contributing to efficient enclosure management and system configuration. A standout feature of the ProLine G2 series is the innovative Smooth Glide latching system. Crafted from high-quality components, this system incorporates a timed latch action that guarantees a secure and solid door seal with remarkably low closure force. This intelligent design minimizes wear and tear on the door and latch mechanism, prolonging the lifespan of the enclosure system. The low closure force also contributes to ease of use for operators, ensuring that doors can be opened and closed efficiently without excessive effort, which is beneficial in high-traffic industrial settings. Key benefits and features include: * **Enhanced Visibility:** Clear polycarbonate windows allow for constant monitoring of internal equipment. * **Robust Construction:** Durable aluminum frame and high-impact polycarbonate for industrial resilience. * **Superior Sealing:** Overlapping door design provides excellent protection against environmental ingress. * **Accessory Integration:** Standard door bar system for easy mounting of additional components. * **Advanced Latching:** Smooth Glide system with timed action for a secure seal and low closure force. Manufactured in the USA, the nVent ProLine G2 Window Overlapping Double Doors represent a commitment to quality and performance. These doors are an ideal solution for applications requiring both protection and visual access to sensitive electronic and electrical equipment, ensuring operational efficiency and equipment longevity. The UNSPSC code 39121334 categorizes these as electrical enclosure doors, highlighting their specific industrial application.
  • Safety glass or polycarbonate (for food and beverage applications)
  • Smooth Glide latching system – for a smooth, reliable and repeatable door close over enclosure lifetime
  • Clean, contemporary design
  • Window doors available for frames up to 1000 mm wide
  • 0.25 in. (6.35 mm) thick window to provide maximum protection and viewing area
  • Standard door bar system on all window doors for easy accessories attachment
  • Low-profile Swing Handle with key lock; other options available
  • Seamless polyurethane gasket (UL component recognized) provides a water-tight, dust-tight seal against moisture and contaminants
  • Timed latch engagement to ensure top and bottom of door catch reliably
  • Durable, double-flanged latch rod and three Delrin® rollers to prevent metal-on-metal grinding

Specifications

Application
Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Door Quantity
2
Finish
Powder Coated
Fits Frame
1800x1600 mm
Material
Mild Steel
Material
Aluminum/Polycarbonate
Product Family
ProLine
Series
ProLine G2
Size
1800x1600mm
Thickness
14 ga
Thickness
1.9 mm
Type
Polycarbonate
Weight
33.2 lb
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2DWO1816 Controller

This guide provides step-by-step instructions for installing and configuring the P2DWO1816 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2DWO1816 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely fastened.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power input terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power input terminals to ensure the controller is receiving the correct voltage before powering it on.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the necessary parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates within specified tolerances.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.