nVent P2DWG206 - ProLine G2 Window Doors, fits 2000x600mm, Aluminum, Glass
nVent

P2DWG206

UPC: 783510316419


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Window Door (SKU: P2DWG206) is engineered to provide secure and convenient visual access to sensitive electronic equipment housed within industrial enclosures. Designed with contemporary aesthetics and robust functionality, this window door seamlessly integrates into modern control and automation systems. Its primary purpose is to allow operators and technicians to monitor internal components, status indicators, and operational readouts without compromising the integrity of the enclosure's environmental protection. Constructed with a durable aluminum frame, the ProLine G2 Window Door is built to withstand demanding industrial environments. The 2000x600mm dimensions offer a substantial viewing area, facilitating easy inspection of larger equipment configurations. The transparent panel is made from high-quality safety glass, ensuring both clarity for visual monitoring and protection against potential impacts or hazards. For applications requiring enhanced durability or specific environmental resistance, alternative materials like polycarbonate may be available in other configurations within the ProLine G2 series. Installation and accessory integration are streamlined thanks to the standard door bar system. This feature allows for the quick and secure attachment of various accessories, enhancing the versatility and usability of the enclosure. The innovative Smooth Glide latching system is a cornerstone of the ProLine G2's design. Manufactured with premium components, it incorporates a timed latch action. This intelligent mechanism guarantees a consistently solid door seal with remarkably low closure force, preventing accidental openings and maintaining optimal internal conditions while minimizing user effort. Key benefits of the nVent ProLine G2 Window Door include: * **Enhanced Visibility:** Clear safety glass provides unobstructed views of internal equipment. * **Robust Construction:** Durable aluminum frame ensures longevity in industrial settings. * **Secure Sealing:** Smooth Glide latching system with timed action ensures a tight seal. * **Easy Accessory Mounting:** Integrated door bar system simplifies attachment of peripherals. * **Modern Design:** Clean, contemporary lines complement modern industrial aesthetics. This window door is an ideal solution for a wide range of industries, including manufacturing, process control, telecommunications, and data centers, where reliable visual monitoring of critical electronic infrastructure is paramount. nVent's commitment to quality and innovation is evident in the ProLine G2 series, offering professionals dependable solutions for enclosure management and operational efficiency. The UNSPSC code 39121334 categorizes this product under 'Enclosure accessories', highlighting its role in comprehensive system design. Manufactured in the US, this product adheres to stringent quality standards.
  • Safety glass or polycarbonate (for food and beverage applications)
  • Smooth Glide latching system – for a smooth, reliable and repeatable door close over enclosure lifetime
  • Clean, contemporary design
  • Window doors available for frames up to 1000 mm wide
  • 0.25 in. (6.35 mm) thick window to provide maximum protection and viewing area
  • Standard door bar system on all window doors for easy accessories attachment
  • Low-profile Swing Handle with key lock; other options available
  • Seamless polyurethane gasket (UL component recognized) provides a water-tight, dust-tight seal against moisture and contaminants
  • Timed latch engagement to ensure top and bottom of door catch reliably
  • Durable, double-flanged latch rod and three Delrin® rollers to prevent metal-on-metal grinding

Specifications

Application
Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
2000 x 600 mm
Material
Mild Steel
Material
Aluminum, Glass
Product Family
ProLine
Series
ProLine G2
Size
2000x600mm
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
68 lb
Package Dimensions (L x W x H)
81 IN x 29.75 IN x 2.75 IN
Package Dimensions (L x W x H)
205.74 cm x 75.565 cm x 6.985 cm
Package Weight (Imperial)
68.000 L
Package Weight (Metric)
30.845 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2DWG206 Controller

This guide provides step-by-step instructions for installing and configuring the P2DWG206 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2DWG206 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using terminal connectors, connect the power supply wires to the designated terminals on the controller. Ensure the connections are tight to prevent any loose wiring.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. This step is crucial for the safe operation of the device.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for your application. Follow the on-screen prompts to complete the setup.

  5. Calibrate the controller

    Perform the calibration procedure as outlined in the user manual. This typically involves adjusting settings to match the specific requirements of your system.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.