Authorized nVent Distributor
nVent P2DW208 - ProLine G2 Window Doors, fits 2000x800mm, Aluminum, Polycarbonate

nVent P2DW208 ProLine G2 Window Doors, fits 2000x800mm, Aluminum, Polycarbonate

UPC: 783510315917


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent ProLine G2 Window Door (SKU: P2DW208)** is a premium industrial-grade viewing solution designed for enclosures housing sensitive electronic equipment. Engineered to meet demanding industrial and commercial applications, this window door combines durability, security, and optical clarity to provide safe and unobstructed visibility into control panels, server racks, and industrial machinery. Built with a robust **aluminum frame** and a **polycarbonate panel**, the ProLine G2 delivers exceptional impact resistance while maintaining compliance with electromagnetic compatibility (EMC) standards, ensuring uninterrupted operation of sensitive electronics. The ProLine G2 is specifically designed to fit **2000x800mm openings**, making it ideal for large control cabinets, industrial automation systems, and data center enclosures. Its **clean, contemporary design** integrates seamlessly into modern industrial environments, offering a professional aesthetic without compromising functionality. The window door features a **standard door bar system**, allowing for easy attachment of accessories such as locks, latches, or ventilation components, enhancing customization and adaptability for diverse applications. A standout feature of the ProLine G2 is its **Smooth Glide latching system**, constructed from high-quality components to ensure long-term reliability. The innovative **timed latch action** provides a secure door seal with minimal closure force, reducing wear on components and improving user experience. This system is particularly beneficial in high-traffic environments where frequent access is required, as it minimizes the risk of damage to the door or enclosure. The polycarbonate panel offers **superior impact resistance** compared to traditional glass, making it suitable for harsh industrial environments where accidental impacts or debris are a concern. Additionally, polycarbonate provides excellent **UV resistance**, ensuring long-term clarity and structural integrity even in outdoor or high-exposure applications. For environments requiring enhanced security or additional protection, the ProLine G2 can also be specified with **clear safety glass** as an alternative panel material. Industries that benefit from the ProLine G2 include **manufacturing, automation, data centers, telecommunications, and utilities**, where reliable access to electronic equipment is critical. The window door’s design allows for quick visual inspections, reducing downtime during maintenance or troubleshooting. Its **EMC compliance** ensures that it does not interfere with the operation of sensitive electronic devices, making it a trusted choice for critical infrastructure. nVent, a global leader in electrical and thermal management solutions, is renowned for its commitment to innovation, quality, and customer support. The ProLine G2 Window Door is a testament to nVent’s expertise in providing solutions that enhance safety, efficiency, and reliability in industrial environments. With a **US-made** construction, the ProLine G2 meets the highest standards of durability and performance, backed by nVent’s reputation for excellence in the electrical enclosure industry. For professionals specifying or installing enclosure accessories, the ProLine G2 offers a **versatile, high-performance solution** that balances functionality, aesthetics, and compliance. Whether used in a factory automation system, a data center rack, or an outdoor electrical enclosure, the ProLine G2 delivers unmatched visibility and protection for critical electronic equipment.
  • Safety glass or polycarbonate (for food and beverage applications)
  • Smooth Glide latching system – for a smooth, reliable and repeatable door close over enclosure lifetime
  • Clean, contemporary design
  • Window doors available for frames up to 1000 mm wide
  • 0.25 in. (6.35 mm) thick window to provide maximum protection and viewing area
  • Standard door bar system on all window doors for easy accessories attachment
  • Low-profile Swing Handle with key lock; other options available
  • Seamless polyurethane gasket (UL component recognized) provides a water-tight, dust-tight seal against moisture and contaminants
  • Timed latch engagement to ensure top and bottom of door catch reliably
  • Durable, double-flanged latch rod and three Delrin® rollers to prevent metal-on-metal grinding

Specifications

Application
Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
2000 x 800 mm
Material
Mild Steel
Product Family
ProLine
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
67 lb
Package Dimensions (L x W x H)
82.5 IN x 36 IN x 3.5 IN
Package Dimensions (L x W x H)
209.55 cm x 91.44 cm x 8.89 cm
Package Weight (Imperial)
67.000 L
Package Weight (Metric)
30.391 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2DW208 PROLINE G2 Enclosure

Installation guide for mounting and wiring the P2DW208 PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Wire strippers, Wire crimpers, Pliers, Safety glasses, Gloves

Supplies needed:

Mounting hardware (screws, bolts, nuts), Wire connectors, Grounding lug, Gasket sealant (if applicable)

  1. Prepare the Mounting Location

    Select a suitable location for the enclosure. Ensure the mounting surface is clean, level, and capable of supporting the weight of the enclosure and its contents. Check the enclosure's nameplate or datasheet for specific mounting requirements and environmental considerations. Wear safety glasses and gloves.

  2. Mark Mounting Holes

    Using a measuring tape and level, position the P2DW208 enclosure at the desired location. Mark the positions for the mounting holes through the enclosure's mounting brackets or designated areas. Verify the marks are level and accurately spaced.

  3. Drill Mounting Holes

    Drill the mounting holes at the marked locations. Ensure the drill bit size is appropriate for the chosen mounting hardware. Clean any debris from the drilled holes.

  4. Mount the Enclosure

    Secure the P2DW208 enclosure to the mounting surface using appropriate mounting hardware (screws, bolts, nuts). Ensure the enclosure is firmly attached and level. Do not overtighten fasteners, as this could damage the enclosure or mounting surface.

  5. Install Internal Components (if applicable)

    If the enclosure is being populated with internal components, follow the specific installation instructions for each component. Ensure proper grounding of all metallic components within the enclosure. Refer to the component datasheets for specific wiring and mounting guidelines.

  6. Wire the Enclosure

    Connect all internal and external wiring according to the enclosure's wiring diagram and relevant electrical codes. Use appropriate wire connectors and ensure all connections are secure. Strip wire ends to the length specified in the component datasheets. Ensure proper grounding of the enclosure itself using the grounding lug.

  7. Final Inspection and Sealing

    Perform a thorough inspection of all mounted components and wiring. Verify all connections are tight and correctly made. If required, apply gasket sealant around the door or lid to ensure environmental protection. Close and secure the enclosure door.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.