nVent P2DW206 ProLine G2 Window Doors, fits 2000x600mm, Aluminum, Polycarbonate
UPC: 783510315870
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Safety glass or polycarbonate (for food and beverage applications)
- Smooth Glide latching system – for a smooth, reliable and repeatable door close over enclosure lifetime
- Clean, contemporary design
- Window doors available for frames up to 1000 mm wide
- 0.25 in. (6.35 mm) thick window to provide maximum protection and viewing area
- Standard door bar system on all window doors for easy accessories attachment
- Low-profile Swing Handle with key lock; other options available
- Seamless polyurethane gasket (UL component recognized) provides a water-tight, dust-tight seal against moisture and contaminants
- Timed latch engagement to ensure top and bottom of door catch reliably
- Durable, double-flanged latch rod and three Delrin® rollers to prevent metal-on-metal grinding
Specifications
Application | Controls and Drives |
Color | Light Gray |
Color Code | RAL 7035 |
Finish | Powder Coated |
Fits Frame | 2000 x 600 mm |
Material | Mild Steel |
Product Family | ProLine |
Thickness | 14 ga |
Thickness | 1.9 mm |
Type | External Mounting for ProLine Industrial Enclosures |
Weight | 55 lb |
Package Dimensions (L x W x H) | 82.5 IN x 28.5 IN x 3 IN |
Package Dimensions (L x W x H) | 209.55 cm x 72.39 cm x 7.62 cm |
Package Weight (Imperial) | 55.000 L |
Package Weight (Metric) | 24.948 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackHow to Install the P2DW206 PROLINE G2 Enclosure
Installation guide for mounting and wiring the P2DW206 PROLINE G2 enclosure.
Estimated time: 1h
Tools needed:
Measuring tape, Level, Drill, Screwdriver, Wire strippers, Wire crimpers, Pliers, Safety glasses, Gloves
Supplies needed:
Mounting hardware (screws, bolts, nuts), Wire connectors, Grounding lug, Gasket sealant (if applicable)
- Prepare the Mounting Location
Select a suitable location for the enclosure. Ensure the mounting surface is clean, level, and capable of supporting the weight of the enclosure and its contents. Check the enclosure's nameplate or datasheet for specific mounting requirements and environmental considerations. Wear safety glasses and gloves.
- Mark Mounting Holes
Using a measuring tape and level, position the P2DW206 enclosure at the desired location. Mark the positions for the mounting holes through the enclosure's mounting brackets or designated areas. Verify the marks are level and accurately spaced.
- Drill Mounting Holes
Drill the mounting holes at the marked locations. Ensure the drill bit size is appropriate for the chosen mounting hardware. Clean any debris from the drilled holes.
- Mount the Enclosure
Secure the P2DW206 enclosure to the mounting surface using appropriate mounting hardware (screws, bolts, nuts). Ensure the enclosure is firmly attached and level. Do not overtighten fasteners, as this could damage the enclosure or mounting surface.
- Install Internal Components (if applicable)
If the enclosure is being populated with internal components, follow the specific installation instructions for each component. Ensure proper grounding of all metallic components within the enclosure. Refer to the component datasheets for specific wiring and mounting guidelines.
- Wire the Enclosure
Connect all internal and external wiring according to the enclosure's wiring diagram and relevant electrical codes. Use appropriate wire connectors and ensure all connections are secure. Strip wire ends to the length specified in the component datasheets. Ensure proper grounding of the enclosure itself using the grounding lug.
- Final Inspection and Sealing
Perform a thorough inspection of all mounted components and wiring. Verify all connections are tight and correctly made. If required, apply gasket sealant around the door or lid to ensure environmental protection. Close and secure the enclosure door.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.