The nVent ProLine G2 Disconnect Door (SKU P2DDR1616) is a specialized component for industrial enclosures, designed for safety and accessibility. This double right-hand disconnect door fits 1600x1600mm nVent ProLine G2 enclosures and features a durable painted finish for environmental protection. It incorporates a hinged mullion with a standard cutout, engineered to accommodate a wide range of flange-mount disconnect devices. An integrated interlock system connects the enclosure doors to the disconnect mullion, preventing access when the disconnect is engaged, thereby enhancing personnel safety. The hinged mullion design provides unobstructed access to the enclosure interior and maximizes utility of the Full Mounting Subpanel (Mounting Plate). This component is crucial for secure and efficient electrical control and distribution systems in sectors like manufacturing, power generation, and telecommunications. Specifications include a 1600x1600mm nominal size and a painted finish.
  • Interlock from enclosure doors to mullion
  • Includes a hinged mullion with a cutout, which accommodates a wide variety of flange-mount disconnect devices
  • Standard options: right standard cutout, right large cutout, left standard cutout
  • Mullion is opened via two quarter-turn cams
  • Integrated interlock system from the doors to the disconnect mullion
  • Interlock must be defeated to unlock either door
  • The primary door must be in the open position to open the secondary door
  • The primary door must be in the open position to open mullion
  • Right-hand disconnects have the mullion on the right; left-hand disconnects have the mullion on the left
  • Doors swing to the left for right-hand disconnects; doors swing to the right for left-hand disconnects

Specifications

Application
Controls and Drives; Arc Flash Safety
Color
Light Gray
Color Code
RAL 7035
Cutout Type
Standard
Door Quantity
2
Finish
Powder Coated
Fits Frame
1600x1600 mm
Fits Frame Height
1600 x 1600 mm
Height
62.3
Height
1,583
IP Rating
IP55
Material
Mild Steel
Product Family
ProLine
Thickness
14 ga
Thickness
1.9 mm
Type
Right Mullion
Weight
67.6 lb
Width
62.9
Width
1,598
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2DDR1616 Controller

This guide provides step-by-step instructions for installing and configuring the P2DDR1616 controller in a modular frame.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Subpanel

  1. Install the disconnect door

    Follow the disconnect door installation instructions to securely attach the PROLINE G2 disconnect door and disconnect mullion to the modular frame.

  2. Attach the operating handle

    Install the disconnect/circuit breaker operating handle on the disconnect mullion according to the manufacturer's instructions. Remove the pivot bracket as shown in the installation guide.

  3. Secure the pivot bracket

    Position the pivot bracket so that the interlock lever fits between the two adjustable studs. Secure the pivot bracket to the disconnect mullion using the shoulder collar and hex nut.

  4. Close and latch the disconnect mullion

    Ensure the disconnect mullion is closed and latched to the PROLINE G2 frame using the sliding latches provided at the top and bottom.

  5. Adjust the door interlock

    Adjust the studs on the pivot bracket so that it is horizontal when the disconnect operating handle is in the 'OFF' position. Ensure proper engagement with the door catch.

  6. Drill mounting holes

    Drill the necessary mounting holes in the subpanel for the specific disconnect switch or circuit breaker being installed, following the manufacturer's instructions.

  7. Install the subpanel

    Install the subpanel in the PROLINE G2 frame at the desired depth, ensuring it is within the recommended depth range for the disconnect.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.