nVent P2CB228 - ProLine G2 Barrier Panel, fits 2200x800mm, Painted
nVent

P2CB228

UPC: 783510313081


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Barrier Panel (SKU P2CB228) is a critical component for industrial enclosure systems, engineered to maintain environmental integrity when joining or ganging multiple enclosures. Designed with precision and manufactured by nVent, a trusted leader in electrical enclosure solutions, this painted barrier panel serves as an essential buffer, preventing the ingress of dust, moisture, and other contaminants that could compromise sensitive electrical and electronic equipment. When deploying complex control systems or modular power distribution units, it is often necessary to connect multiple enclosures together. The ProLine G2 Barrier Panel seamlessly integrates into these configurations, creating a sealed interface between adjacent units. This ensures that the NEMA or IP rating of the individual enclosures is maintained across the entire joined system, a crucial factor for operational reliability and safety in demanding industrial environments such as manufacturing plants, data centers, and utility substations. The painted finish of this barrier panel not only provides a professional aesthetic but also offers an additional layer of protection against corrosion and environmental degradation. This makes it suitable for a wide range of applications, including those with moderate exposure to chemicals or fluctuating temperatures. The robust construction, characteristic of nVent's ProLine series, guarantees durability and longevity, even under continuous operational stress. Key benefits and features of the nVent ProLine G2 Barrier Panel include: * **Environmental Sealing:** Effectively seals gaps between ganged enclosures, preserving the overall environmental protection rating. * **Modular System Expansion:** Facilitates the seamless integration and expansion of enclosure systems. * **Durable Construction:** Built with high-quality materials for long-term performance in industrial settings. * **Corrosion Resistance:** The painted finish enhances protection against environmental factors. * **Manufacturer Reliability:** Backed by the expertise and quality assurance of nVent. Installation of the ProLine G2 Barrier Panel is designed to be straightforward, integrating with standard mounting hardware for the ProLine G2 enclosure series. This minimizes downtime and complexity during system setup or expansion. Professionals in electrical engineering, panel building, and industrial automation rely on nVent products for their consistent performance and adherence to stringent industry standards. The P2CB228 model, with its specific dimensions of 2200x800mm, is tailored for compatibility with corresponding enclosure sizes, ensuring a perfect fit and optimal sealing performance. By choosing the nVent ProLine G2 Barrier Panel, you are investing in the integrity and longevity of your critical electrical infrastructure.
  • Barrier between joined or ganged enclosure
  • EMC options designed to be used as electrical buffers between joined or ganged enclosure systems.
  • All mounting hardware included
  • All mounting hardware included
  • Facilitates modular expansion of electrical and control systems.

Specifications

Application
Controls and Drives; Power Distribution; Arc Flash Safety
Color
Light Gray
Color
Painted
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
2200x800 mm
Material
Mild Steel
Product Family
ProLine
Series
ProLine G2
Size
2200x800mm
Thickness
16 ga
Thickness
1.52 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
55 lb
Package Dimensions (L x W x H)
91 IN x 34 IN x 2.5 IN
Package Dimensions (L x W x H)
231.14 cm x 86.36 cm x 6.35 cm
Package Weight (Imperial)
55.000 L
Package Weight (Metric)
24.948 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2CB228 Controller

This guide provides step-by-step instructions for installing and configuring the P2CB228 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2CB228 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and properly insulated.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, recheck your connections.

  4. Configure the controller settings

    Follow the manufacturer’s instructions to access the configuration menu on the controller. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Perform the calibration process as outlined in the user manual. This may involve adjusting settings based on the specific application and verifying the output.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.