nVent P2CB125 - ProLine G2 Barrier Panel, fits 1200x500mm, Painted
nVent

P2CB125

UPC: 783510312749


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance the integrity and functionality of your industrial enclosure systems with the nVent ProLine G2 Barrier Panel (SKU P2CB125). Designed by nVent, a trusted leader in electrical enclosure solutions, this painted barrier panel serves as a critical component for joining or ganging multiple enclosure units. Its primary function is to create a robust environmental seal, preventing the ingress of dust, moisture, and other contaminants when enclosures are placed side-by-side or end-to-end. The ProLine G2 Barrier Panel is engineered for seamless integration with nVent's ProLine G2 enclosure series, ensuring a precise fit and maintaining the high standards of protection expected from industrial-grade equipment. When mounted, it effectively separates the internal environments of adjacent enclosures, crucial for applications where different atmospheric conditions or protection levels are required within a single assembly. This is particularly vital in harsh industrial settings such as manufacturing plants, chemical processing facilities, power generation stations, and telecommunications infrastructure, where maintaining a controlled internal environment is paramount for the longevity and reliable operation of sensitive electrical and electronic components. Key benefits of utilizing the nVent ProLine G2 Barrier Panel include: * **Environmental Integrity:** Effectively seals gaps between enclosures, preserving NEMA or IP ratings and protecting internal equipment from external elements. * **Modular Design:** Facilitates the creation of larger, custom enclosure configurations by allowing standard enclosures to be joined securely. * **Durability:** Constructed from high-quality materials and finished with a durable paint for resistance to corrosion and wear in demanding environments. * **Ease of Installation:** Designed for straightforward mounting, minimizing downtime during system expansion or modification. * **Manufacturer Reliability:** Backed by nVent's extensive experience and commitment to quality in electrical protection solutions. This 1200x500mm painted barrier panel is an essential accessory for any facility looking to optimize its enclosure strategy. By preventing cross-contamination of environments and maintaining a consistent internal atmosphere, it contributes directly to the safety, reliability, and operational efficiency of your critical infrastructure. Invest in the nVent ProLine G2 Barrier Panel for superior protection and a more robust, integrated enclosure system.
  • Barrier between joined or ganged enclosure
  • EMC options designed to be used as electrical buffers between joined or ganged enclosure systems.
  • All mounting hardware included
  • All mounting hardware included
  • Ideal for industrial applications requiring robust protection.

Specifications

Application
Arc Flash Safety; Controls and Drives; Power Distribution
Color
Light Gray
Color
Painted
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1200x500 mm
Ip Rating
IP66/IP67
Material
Mild Steel
Material
Steel
Mounting Type
Mounted between enclosures
Nema Rating
Type 4X
Product Family
ProLine
Series
ProLine G2
Size
1200x500mm
Thickness
1.52 mm
Thickness
16 ga
Type
External Mounting for ProLine Industrial Enclosures
Weight
29.68 lb
Package Dimensions (L x W x H)
64 IN x 25 IN x 3 IN
Package Dimensions (L x W x H)
162.56 cm x 63.5 cm x 7.62 cm
Package Weight (Imperial)
29.680 L
Package Weight (Metric)
13.463 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2CB125 Controller

This guide provides step-by-step instructions for the installation and initial setup of the P2CB125 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2CB125 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using terminal connectors, connect the power supply wires to the designated input terminals on the controller. Verify that the connections are secure.

  3. Configure initial settings

    Power on the controller and access the configuration menu using the provided interface. Set the required parameters according to your application needs.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.