nVent P2BP2184 ProLine G2 200-mm Plinth Bases, fits 1800x400mm, Black, Steel
UPC: 783510340674
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Four access panels for cable management options at the base of the enclosure
- Sturdy cast aluminum corner supports for superior performance under load
- Corner blocks can be installed onto the base of the frame independent of the cover plates, enabling the cover plates to be attached after integration and just prior to shipment
- Stackable up to 400mm in height using Plinth Base Stacking Kit (not included)
- 100 mm or 200 mm options
- To maintain a NEMA Type 12 environmental rating, gland plate must also be used in the base of the enclosure
- Installation hardware included
- Cover plates are 16-gauge (1.5 mm) steel
Specifications
Application | Controls and Drives; Power Distribution |
Color | Black |
Color | Jet Black |
Color Code | RAL 9005 |
Depth | 14.33 |
Depth | 364 |
Finish | Powder Coated |
Fits Frame | 1800x400 mm |
Height | 7.58 |
Height | 193 |
Material | Steel |
Material | Mild Steel |
Product Family | ProLine |
Series | ProLine G2 |
Size | 200mm x 1800mm x 400mm |
Thickness | 1.52 mm |
Thickness | 16 ga |
Type | 200mm |
Weight | 65 lb |
Width | 70.83 |
Width | 1,799 |

LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Install the P2BP2184 PROLINE G2 Enclosure
Installation guide for mounting and wiring the P2BP2184 PROLINE G2 enclosure.
Estimated time: 1h
Tools needed:
Measuring tape, Level, Drill, Screwdriver, Wire strippers, Wire crimpers, Multimeter
Supplies needed:
Mounting hardware (screws, anchors), Wire connectors, Gland fittings, Grounding lug, Grounding wire
- Select Mounting Location
Choose a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Consider environmental factors such as temperature, humidity, and potential exposure to corrosive elements. Verify that there is adequate space for installation and future maintenance.
- Prepare the Mounting Surface
Using a measuring tape and level, mark the desired mounting points on the surface. Drill pilot holes for the mounting hardware. If mounting to concrete or masonry, insert appropriate anchors.
- Mount the Enclosure
Position the P2BP2184 enclosure against the prepared mounting surface. Secure the enclosure using appropriate mounting hardware (screws, bolts). Ensure the enclosure is level and firmly attached to the surface. Refer to the datasheet for specific mounting hole locations and hardware recommendations.
- Install Gland Fittings
Determine the locations for cable entry and exit. Drill holes in the enclosure wall if necessary, according to the size of the gland fittings. Install the gland fittings into the drilled holes and tighten them securely.
- Install Grounding
Connect the grounding lug to the designated grounding point inside the enclosure using the provided screw. Attach a grounding wire from the grounding lug to the main grounding point of the system. Ensure a secure and low-resistance connection. Refer to local electrical codes for grounding requirements.
- Wire the Enclosure
Route the external cables through the installed gland fittings. Strip the cable ends to the appropriate length. Connect the wires to the internal components (e.g., terminal blocks, devices) according to the wiring diagram. Use appropriate wire connectors and ensure all connections are secure. Verify wiring against the product's wiring diagram and electrical codes. Consult the nameplate or datasheet for specific wiring details and ratings.
- Final Inspection and Sealing
Double-check all electrical connections for tightness and correctness. Ensure all gland fittings are properly tightened to maintain the enclosure's environmental rating. Close and secure the enclosure door. Verify the integrity of the door gasket for a proper seal.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.