nVent P2BP1D188 - ProLine G2 Disconnect Plinth Base, 100mm, fits 1800x800mm, Black, Steel
nVent

P2BP1D188

UPC: 783510350673


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Disconnect Plinth Base (SKU: P2BP1D188) is a critical component for constructing robust and customized industrial enclosure solutions. Designed to integrate seamlessly with ProLine G2 Disconnect Frames and Doors, this 100mm plinth base is specifically engineered for enclosure widths exceeding 1000mm. Its primary function is to elevate and stabilize the enclosure, providing essential clearance for ventilation, cable management, and protection against environmental factors such as dust and moisture. The black steel construction ensures durability and resistance to corrosion, making it suitable for demanding industrial environments. This plinth base shares the same high-quality manufacturing standards as other ProLine G2 components. It is identical in design to standard ProLine G2 components, including solid tops, gland plates, and mounting subpanels, with one key distinction: the center support is offset by 100mm. This offset is a deliberate design feature to accommodate the hinged mullion, a crucial element for accessing and maintaining the enclosure's internal components without compromising structural integrity. This thoughtful engineering allows for flexible configuration of large-scale disconnect enclosure systems. Applications for the nVent ProLine G2 Disconnect Plinth Base are widespread across various industries. It is commonly found in: * **Manufacturing Facilities:** Protecting electrical control systems, power distribution units, and automation equipment. * **Data Centers:** Housing critical networking and server infrastructure where environmental control is paramount. * **Telecommunications:** Safeguarding sensitive communication equipment from external elements. * **Utility Providers:** Ensuring the reliability of power distribution and control systems in substations and outdoor installations. The ProLine G2 system, including this plinth base, is renowned for its modularity and ease of assembly. Professionals can configure custom enclosure solutions tailored to specific site requirements and equipment needs. The 100mm height offers adequate space for airflow and cable routing, contributing to the overall efficiency and longevity of the enclosed equipment. nVent's commitment to quality and innovation is evident in the robust design and material selection of this plinth base, providing peace of mind for critical infrastructure protection. The US origin further underscores its adherence to stringent manufacturing standards. When selecting an enclosure base, factors such as load-bearing capacity, environmental sealing, and compatibility with other enclosure components are vital. The ProLine G2 Disconnect Plinth Base excels in these areas, offering a reliable foundation for complex electrical and electronic systems. Its steel construction provides inherent strength, while the black finish offers a professional aesthetic suitable for any industrial setting. Investing in nVent ProLine G2 components means investing in dependable, long-lasting enclosure solutions designed for the challenges of modern industry.
  • Solution for disconnect enclosures widths >1000 mm wide
  • Four access panels for cable management options at the base of the enclosure
  • Sturdy cast aluminum corner supports for superior performance under load
  • Corner blocks can be installed onto the base of the frame independent of the cover plates, enabling the cover plates to be attached after integration and just prior to shipment
  • Stackable up to 400mm in height using Plinth Base Stacking Kit (not included)
  • 100 mm or 200 mm options
  • To maintain a NEMA Type 12 environmental rating, gland plate must also be used in the base of the enclosure
  • Installation hardware included

Specifications

Application
Power Distribution; Controls and Drives
Color
Black
Color
Jet Black
Color Code
RAL 9005
Finish
Powder Coated
Fits Frame
1800 x 800 mm
Material
Steel
Material
Mild Steel
Product Family
ProLine
Series
ProLine G2
Size
100mm
Thickness
16 ga
Thickness
1.52 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
18.62 lb
Package Dimensions (L x W x H)
74.87 IN x 7.75 IN x 6.75 IN
Package Dimensions (L x W x H)
190.1698 cm x 19.685 cm x 17.145 cm
Package Weight (Imperial)
18.620 L
Package Weight (Metric)
8.446 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2BP1168 Controller

This guide provides step-by-step instructions for installing and configuring the P2BP1168 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BP1168 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for your application. Follow the on-screen instructions to complete the setup.

  5. Calibrate the controller

    Perform a calibration of the controller by following the calibration procedure outlined in the user manual. This may involve adjusting settings based on the specific application requirements.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.