nVent P2BP1D185 - ProLine G2 Disconnect Plinth Base, 100mm, fits 1800x500mm, Black, Steel
nVent

P2BP1D185

UPC: 783510350659


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Disconnect Plinth Base (SKU: P2BP1D185) is a critical component for constructing robust and customized industrial enclosure solutions. Designed to integrate seamlessly with ProLine G2 Disconnect Frames and Doors, this 100mm black steel plinth base is specifically engineered for enclosures with dimensions of 1800mm in height and 500mm in width. Its primary function is to elevate and stabilize the enclosure, providing essential clearance for ventilation, cable management, and protection against environmental factors such as moisture and dust ingress. This plinth base is part of the ProLine G2 Disconnect Components series, which allows for the configuration of custom disconnect enclosure solutions for applications requiring widths greater than 1000mm. A key design feature of these components, including this plinth base, is the offset center support. This offset is intentionally designed to accommodate the hinged mullion, a crucial element for accessing and maintaining the internal components of wider enclosures without compromising structural integrity. This thoughtful engineering ensures that even large-scale enclosures maintain their security and functionality. The ProLine G2 Disconnect Plinth Base is constructed from durable black steel, offering excellent resistance to corrosion and mechanical stress, making it suitable for demanding industrial environments. Its 100mm height provides adequate space for essential under-enclosure services and airflow, contributing to the overall thermal management and longevity of the enclosed electrical or electronic equipment. Installation is straightforward, designed for efficient integration with the ProLine G2 system, minimizing downtime during setup. Industries that rely on secure and adaptable enclosure solutions, such as manufacturing, power distribution, telecommunications, and automation, will find the nVent ProLine G2 Disconnect Plinth Base to be an indispensable part of their infrastructure. The nVent brand is synonymous with quality and reliability in the enclosure market, offering products that meet stringent industry standards and provide long-term performance. By choosing nVent ProLine G2 components, professionals ensure the safety, accessibility, and operational efficiency of their critical equipment installations. This plinth base, along with other ProLine G2 accessories, empowers engineers and technicians to build precisely tailored enclosure systems that meet the unique challenges of modern industrial applications. Key benefits include: * **Enhanced Stability and Support:** Provides a solid foundation for large enclosures. * **Optimized Cable Management:** Offers clearance for under-enclosure wiring and conduits. * **Environmental Protection:** Lifts enclosures off the floor, reducing exposure to moisture and debris. * **System Integration:** Designed to work seamlessly with nVent ProLine G2 Frames and Doors. * **Durable Construction:** Made from robust black steel for longevity in harsh conditions. * **Customizable Solutions:** Facilitates the creation of tailored enclosure configurations for widths over 1000mm.
  • Solution for disconnect enclosures widths >1000 mm wide
  • Four access panels for cable management options at the base of the enclosure
  • Sturdy cast aluminum corner supports for superior performance under load
  • Corner blocks can be installed onto the base of the frame independent of the cover plates, enabling the cover plates to be attached after integration and just prior to shipment
  • Stackable up to 400mm in height using Plinth Base Stacking Kit (not included)
  • 100 mm or 200 mm options
  • To maintain a NEMA Type 12 environmental rating, gland plate must also be used in the base of the enclosure
  • Installation hardware included

Specifications

Application
Power Distribution; Controls and Drives
Color
Black
Color
Jet Black
Color Code
RAL 9005
Finish
Powder Coated
Fits Frame
1800 x 500 mm
Material
Steel
Material
Mild Steel
Product Family
ProLine
Series
ProLine G2
Size
100mm
Thickness
16 ga
Thickness
1.52 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
17.02 lb
Package Dimensions (L x W x H)
74.87 IN x 7.75 IN x 6.75 IN
Package Dimensions (L x W x H)
190.1698 cm x 19.685 cm x 17.145 cm
Package Weight (Imperial)
17.020 L
Package Weight (Metric)
7.720 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2BP1168 Controller

This guide provides step-by-step instructions for installing and configuring the P2BP1168 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BP1168 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for your application. Follow the on-screen instructions to complete the setup.

  5. Calibrate the controller

    Perform a calibration of the controller by following the calibration procedure outlined in the user manual. This may involve adjusting settings based on the specific application requirements.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.