Authorized nVent Distributor
nVent P2BP1186 - ProLine G2 100-mm Plinth Bases, fits 1800x600mm, Black, Steel

nVent P2BP1186 ProLine G2 100-mm Plinth Bases, fits 1800x600mm, Black, Steel

UPC: 783510310844


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine G2 100-mm Plinth Bases (SKU: P2BP1186) are precision-engineered steel bases designed to elevate and support industrial enclosures while providing critical cable management infrastructure. These robust plinth bases install directly beneath enclosures measuring 1800x600mm, creating a secure foundation that protects sensitive equipment from floor-level contaminants while facilitating organized cable entry from below. Manufactured by nVent, a global leader in thermal management and electrical infrastructure solutions, the ProLine G2 series delivers the durability and performance required in demanding industrial environments where reliability cannot be compromised. Engineered for compatibility with nVent’s ProLine G2 enclosure systems, these 100-mm black steel plinth bases are constructed from high-grade steel to withstand heavy loads, vibration, and environmental stressors common in manufacturing plants, data centers, utilities, and commercial facilities. The black powder-coated finish provides enhanced corrosion resistance and a professional appearance, ensuring long-term performance even in harsh or high-traffic areas. Unlike generic plinth solutions, the ProLine G2 bases are specifically designed to integrate seamlessly with nVent’s enclosure portfolio, offering a cohesive, code-compliant solution that simplifies installation and maintenance. Primary applications for the ProLine G2 100-mm Plinth Bases include industrial control panels, automation systems, electrical distribution enclosures, and telecommunications housings where cable ingress from the floor is required without compromising enclosure integrity. These bases are ideal for facilities requiring NEMA-rated protection, IP-rated ingress resistance, or compliance with IEC standards for electrical safety. Common industries include oil and gas, chemical processing, food and beverage, pharmaceuticals, and renewable energy—sectors where equipment reliability and regulatory compliance are paramount. Installation is straightforward thanks to the pre-drilled mounting holes and modular design, which aligns with standard enclosure footprints. Professionals appreciate the ability to route cables through the plinth’s open base, reducing clutter and improving airflow beneath the enclosure. This design not only enhances safety by minimizing trip hazards but also simplifies future upgrades or reconfigurations. The 100-mm height provides sufficient clearance for cable bending radius compliance while maintaining a low-profile aesthetic that integrates well with modern facility layouts. nVent’s reputation for engineering excellence is reflected in the ProLine G2 series, which leverages decades of expertise in thermal management and electrical protection. The company’s commitment to innovation is evident in features like the reinforced steel construction, which resists deformation under load, and the precision-engineered fit, which eliminates the need for custom fabrication. For engineers and facility managers seeking a reliable, off-the-shelf solution for enclosure elevation and cable management, the ProLine G2 100-mm Plinth Base (P2BP1186) delivers unmatched performance, durability, and compatibility—making it a trusted choice for critical infrastructure projects worldwide.
  • Four access panels for cable management options at the base of the enclosure
  • Sturdy cast aluminum corner supports for superior performance under load
  • Corner blocks can be installed onto the base of the frame independent of the cover plates, enabling the cover plates to be attached after integration and just prior to shipment
  • Stackable up to 400mm in height using Plinth Base Stacking Kit (not included)
  • 100 mm or 200 mm options
  • To maintain a NEMA Type 12 environmental rating, gland plate must also be used in the base of the enclosure
  • Installation hardware included
  • Cover plates are 16-gauge (1.5 mm) steel

Specifications

Application
Power Distribution; Controls and Drives
Color
Black
Color
Jet Black
Color Code
RAL 9005
Depth
22.21
Depth
564
Finish
Powder Coated
Fits Frame
1800x600 mm
Height
3.94
Height
100
Material
Steel
Material
Mild Steel
Product Family
ProLine
Series
ProLine G2
Size
1800x600mm
Thickness
1.52 mm
Thickness
16 ga
Type
100mm
Weight
22 lb
Width
70.83
Width
1,799
Package Dimensions (L x W x H)
73.5 IN x 7.75 IN x 6.5 IN
Package Dimensions (L x W x H)
186.69 cm x 19.685 cm x 16.51 cm
Package Weight (Imperial)
22.000 L
Package Weight (Metric)
9.979 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2BP1186 Controller

Complete installation guide for mounting and wiring the P2BP1186 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BP1186 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using terminal connectors, connect the power supply wires to the designated input terminals on the controller. Ensure correct polarity to avoid damage.

  3. Verify connections

    Use a multimeter to check the voltage at the input terminals. Confirm that the voltage is within the specified range for the P2BP1186 controller.

  4. Configure the controller settings

    Access the configuration menu via the controller interface. Set the necessary parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure accurate readings and performance. Adjust settings as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.