Authorized nVent Distributor
nVent P2BGP86HF - ProLine G2 Gland Plates, fits 800x600mm, EMC

nVent P2BGP86HF ProLine G2 Gland Plates, fits 800x600mm, EMC

UPC: 783510329624


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent ProLine G2 Gland Plate (SKU: P2BGP86HF)** is a premium-grade steel gland plate designed for industrial cable management and enclosure protection. Engineered to fit 800x600mm openings, this EMC-compliant component integrates seamlessly with ProLine G2 plinth bases to deliver robust NEMA 12-rated solutions for demanding environments. Whether deployed in manufacturing plants, data centers, or utility installations, the gland plate ensures secure cable entry while maintaining environmental resistance and structural integrity. **Key Features and Benefits:** - **Heavy-Duty Steel Construction**: Built from high-strength steel, the ProLine G2 Gland Plate is engineered to support the weight of technicians during installation or maintenance, reducing the risk of deformation or failure under load. This durability is critical in industrial settings where enclosures may be accessed frequently for upgrades or repairs. - **NEMA 12 Compliance**: The gland plate meets NEMA 12 standards, providing protection against dust, dirt, and non-corrosive liquids. This makes it ideal for use in harsh industrial environments, including food processing, chemical handling, and automotive manufacturing, where ingress protection is a priority. - **EMC Compatibility**: Designed with electromagnetic compatibility in mind, the gland plate minimizes interference with sensitive electronic equipment, ensuring reliable operation in control rooms, automation systems, and telecommunications infrastructure. - **Modular Integration with ProLine G2**: Compatible with the ProLine G2 series, this gland plate is part of a cohesive system that simplifies cable management and enclosure design. The modular approach allows for easy customization and scalability, accommodating evolving infrastructure needs without compromising performance. - **Enhanced Workflow Efficiency**: The unique **Duro-Stand Gland Plate** design, exclusive to nVent’s ProLine G2 series, enables technicians to work safely and efficiently on enclosures without the need for additional support structures. This feature streamlines maintenance operations and reduces downtime in critical applications. **Typical Applications:** The ProLine G2 Gland Plate is widely used in industries such as: - **Manufacturing**: For cable entry points in control panels, motor enclosures, and machinery housing. - **Data Centers**: To manage high-density cabling while maintaining NEMA 12 protection against dust and moisture. - **Utilities**: In electrical substations and renewable energy installations where environmental resilience is essential. - **Food & Beverage**: In washdown environments where hygiene and corrosion resistance are required. - **Automotive**: For protecting wiring harnesses and control systems in production facilities. **Installation and Selection Considerations:** When selecting a gland plate for an industrial enclosure, professionals prioritize factors such as material strength, ingress protection rating, and compatibility with existing systems. The **nVent ProLine G2 Gland Plate** excels in all these areas, offering a balance of durability, compliance, and ease of use. Installation is straightforward, with pre-drilled mounting holes for secure attachment to the plinth base. The gland plate’s EMC compliance ensures it meets stringent electromagnetic interference (EMI) requirements, making it suitable for sensitive electronic environments. **Why Choose nVent?** As a global leader in thermal management and electrical protection solutions, nVent delivers products that combine innovation with reliability. The ProLine G2 series, including the gland plate (SKU: P2BGP86HF), reflects the company’s commitment to engineering excellence and customer-centric design. With a reputation for durability and performance, nVent solutions are trusted by professionals in industries where failure is not an option. Whether upgrading existing infrastructure or designing new systems, the ProLine G2 Gland Plate provides the performance and protection needed to keep operations running smoothly.
  • Consists of a base mounting surface and adjustable foam gasketed gland plates that permit cable entry
  • Sturdy, adjustable gland plates designed to bear the weight of a person
  • Number of plates varies with depth: 400 mm and 500 mm (3 plates); 600 mm (4 plates); 800 mm (6 plates); 1000 mm (8 plates)
  • Galvanized or painted versions
  • Sealed to maintain NEMA Type 12 rating
  • Gland Plates are finished with paint over plated surfaces
  • Can be used with Plinth Base (100 mm or 200 mm), 100 mm Solid Plinth Base, Mobile Base or Transportation Base
  • Can be used without a base if casters, levelers or frame feet are installed
  • Can be rotated 180 degrees for front or rear cable entry
  • Installation hardware included

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Finish
Galvanized
Fits Frame
800X600 mm
Material
Steel
Material
Mild Steel
Nema Rating
NEMA 12
Product Family
ProLine
Series
ProLine G2
Size
800x600mm
Specialty
Galvanized, EMC Components
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
17.16 lb
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2BGP86HF PROLINE G2 Enclosure

Installation guide for mounting and securing the P2BGP86HF PROLINE G2 enclosure.

Estimated time: 1h

Tools needed:

Measuring tape, Level, Drill, Screwdriver, Wrench set

Supplies needed:

Mounting hardware, Gasket, Door seals

  1. Prepare the Mounting Location

    Select a suitable location for the enclosure. Ensure the surface is level and capable of supporting the weight of the enclosure and its contents. Measure and mark the mounting hole positions according to the enclosure's dimensions. Refer to the datasheet for specific dimensions and weight.

  2. Mount the Enclosure

    Drill pilot holes at the marked locations. Secure the P2BGP86HF enclosure to the mounting surface using appropriate mounting hardware. Verify that the enclosure is securely fastened and level.

  3. Install Gaskets and Seals

    Apply the provided gasket to the enclosure door or frame according to the instructions. Ensure a proper seal to maintain the enclosure's environmental rating. Check the datasheet for specific gasket placement and type.

  4. Install Internal Components (if applicable)

    If mounting internal components such as backplates or subpanels, follow the specific instructions for those items. Ensure all components are securely fastened within the enclosure.

  5. Wire the Enclosure (if applicable)

    If the enclosure requires wiring for internal equipment, follow all electrical safety precautions. Use appropriate wire gauges and connectors. Refer to the equipment's documentation for specific wiring diagrams and requirements. Ensure all connections are tight and properly insulated.

  6. Close and Secure the Door

    Carefully close the enclosure door, ensuring that no wires or components are pinched. Secure the door using the provided latches or locking mechanism. Verify that the door is properly sealed.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.