nVent P2BGP185 - ProLine G2 Gland Plates, fits 1800x500mm, Painted
nVent

P2BGP185

UPC: 783510310011


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Gland Plate (SKU: P2BGP185) is a robust and intelligently designed component for industrial enclosure cable management. Engineered to integrate seamlessly with plinth bases, this painted gland plate ensures efficient and organized routing of electrical conduits and cables, crucial for maintaining operational integrity and safety within demanding industrial environments. Its primary function is to provide a secure and accessible entry point for cables into the enclosure, while simultaneously preserving the enclosure's environmental protection rating, such as NEMA 12. What sets the ProLine G2 Gland Plate apart is its innovative Duro-Stand design. This feature is a testament to nVent's commitment to enhancing user experience and operational efficiency. The Duro-Stand Gland Plate is engineered to withstand significant weight, specifically designed to bear the load of a person. This unique capability dramatically simplifies maintenance and installation tasks. Technicians can comfortably stand on the installed gland plate, gaining easier access to the enclosure's interior without requiring additional scaffolding or support structures. This not only saves time and labor costs but also significantly improves safety during on-site work. Crafted with the high standards expected from nVent, a global leader in electrical enclosure solutions, the ProLine G2 Gland Plate is built for durability and long-term performance. The painted finish provides an additional layer of protection against corrosion and environmental degradation, making it suitable for a wide range of industrial applications including manufacturing plants, data centers, power generation facilities, and process control systems. The precise dimensions of 1800mm x 500mm ensure compatibility with corresponding enclosure sizes, facilitating a clean and professional installation. Key benefits and features of the nVent ProLine G2 Gland Plate include: * **Superior Cable Management:** Facilitates organized and secure cable entry, protecting against damage and ensuring compliance with electrical codes. * **Enhanced Safety and Accessibility:** The Duro-Stand feature allows personnel to safely stand on the plate, improving access for maintenance and installation. * **Maintained Environmental Rating:** Designed to work in conjunction with plinth bases to uphold NEMA 12 and other relevant protection standards. * **Durable Construction:** Manufactured by nVent, a trusted name in industrial solutions, ensuring reliability and longevity. * **Optimized for ProLine G2 Enclosures:** Specifically designed for seamless integration with the ProLine G2 enclosure system. When selecting cable management solutions for critical infrastructure, the nVent ProLine G2 Gland Plate offers a compelling combination of functionality, safety, and durability. Its thoughtful engineering addresses common challenges faced by technicians, making it an indispensable component for any industrial electrical installation requiring efficient and safe cable access.
  • Consists of a base mounting surface and adjustable foam gasketed gland plates that permit cable entry
  • Sturdy, adjustable gland plates designed to bear the weight of a person
  • Number of plates varies with depth: 400 mm and 500 mm (3 plates); 600 mm (4 plates); 800 mm (6 plates); 1000 mm (8 plates)
  • Galvanized or painted versions
  • Sealed to maintain NEMA Type 12 rating
  • Gland Plates are finished with paint over plated surfaces
  • Can be used with Plinth Base (100 mm or 200 mm), 100 mm Solid Plinth Base, Mobile Base or Transportation Base
  • Can be used without a base if casters, levelers or frame feet are installed
  • Can be rotated 180 degrees for front or rear cable entry
  • Installation hardware included

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1800x500 mm
Gland Plate Quantity
3
Material
Mild Steel
Product Family
ProLine
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
35 lb
Package Dimensions (L x W x H)
2 IN x 2 IN x 2 IN
Package Dimensions (L x W x H)
5.08 cm x 5.08 cm x 5.08 cm
Package Weight (Imperial)
35.000 L
Package Weight (Metric)
15.876 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2BGP185 Controller

This guide provides step-by-step instructions for installing and configuring the P2BGP185 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BGP185 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated power terminals on the controller. Ensure correct polarity to avoid damage.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to confirm that the controller is receiving the correct voltage.

  4. Configure the controller settings

    Access the controller's configuration interface via a connected device and input the necessary settings as per your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate performance of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.