Overview
- 16 gauge (1.5 mm) steel
- Light Gray polyester powder paint finish
- All mounting hardware included
- Optimizes internal space utilization within enclosures
- Light gray finish for professional aesthetic and corrosion resistance
Specifications
Application | Power Distribution; Controls and Drives |
Color | Light Gray |
Color Code | RAL 7035 |
Depth | 27.8 |
Depth | 707 |
Finish | Powder Coated |
Fits Frame | 600 x 800 mm |
Material | Steel |
Material | Mild Steel |
Mounting Type | Frame Mount |
Product Family | ProLine |
Series | ProLine G2 |
Size | 600x800 |
Thickness | 1.52 mm |
Thickness | 16 ga |
Type | Internal Mounting for ProLine Industrial Enclosures |
Weight | 13.9 lb |
Width | 548 mm |
Width | 548 |
Package Dimensions (L x W x H) | 31.75 IN x 25.5 IN x 2 IN |
Package Dimensions (L x W x H) | 80.645 cm x 64.77 cm x 5.08 cm |
Package Weight (Imperial) | 13.900 L |
Package Weight (Metric) | 6.305 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackHow to Install the P2ASHF68 PROLINE G2
Installation guide for mounting and wiring the P2ASHF68 PROLINE G2 enclosure.
Estimated time: 1h
Tools needed:
Measuring tape, Level, Drill, Screwdriver, Wire strippers, Wire crimpers, Pliers, Safety glasses, Gloves
Supplies needed:
Mounting hardware, Wire connectors, Grommets, Strain relief fittings
- Prepare the Mounting Location
Select a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Check the nameplate or datasheet for specific load ratings. Use a measuring tape and level to mark the mounting hole positions.
- Drill Mounting Holes
Drill the mounting holes in the prepared surface according to the marked positions. Ensure the holes are appropriately sized for the chosen mounting hardware. Wear safety glasses during drilling.
- Mount the Enclosure
Secure the P2ASHF68 enclosure to the mounting surface using appropriate mounting hardware. Ensure the enclosure is level and firmly attached. Verify that the mounting is secure and can withstand the expected load.
- Prepare for Wiring
Open the enclosure door. Identify the designated knockout locations for cable entry. Remove the appropriate knockout(s) using pliers or a knockout punch. Install grommets or strain relief fittings as needed to protect wiring.
- Install Components and Wiring
Install any internal components according to their specific instructions. Route wiring through the installed grommets or strain relief fittings. Use wire strippers and crimpers to prepare wire ends and attach appropriate connectors. Ensure all connections are secure and properly insulated. Refer to the enclosure's internal layout or wiring diagrams for guidance. Check the nameplate or datasheet for any specific wiring requirements or limitations.
- Final Inspection and Closure
Verify all wiring connections are correct and secure. Ensure all internal components are properly installed. Close and latch the enclosure door securely. Perform a final visual inspection to ensure the installation is complete and safe.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.