nVent P2AIBP108 - ProLine G2 Internal Barrier Panel, 1000x800, Steel, Light Gray
nVent

P2AIBP108

UPC: 783510364342


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Internal Barrier Panel (SKU: P2AIBP108) is a critical component for advanced enclosure segmentation and organization. Designed to mount horizontally within nVent ProLine G2 enclosures, this panel effectively divides the vertical space into distinct bays. This capability is particularly valuable in complex electrical and automation systems where component separation is essential for safety, thermal management, and accessibility. The robust steel construction ensures durability and longevity in demanding industrial environments. Finished in a light gray, it integrates seamlessly with the aesthetic and functional design of the ProLine G2 series. This internal barrier panel is frequently employed in partial door enclosure solutions, enabling the creation of specialized zones within a single enclosure. For instance, one bay might house sensitive control electronics, while another accommodates high-power distribution components, preventing interference and simplifying maintenance. The panel's design facilitates a clean and organized internal layout, which is paramount for efficient troubleshooting and upgrades. By segmenting the enclosure, users can also improve airflow management, directing cooling to specific areas or isolating heat-generating equipment. This contributes to the overall reliability and performance of the enclosed systems. Key applications for the nVent ProLine G2 Internal Barrier Panel include: * **Industrial Automation:** Separating PLCs, drives, and I/O modules. * **Power Distribution:** Isolating different voltage levels or circuit breaker sections. * **Telecommunications:** Organizing network equipment and power supplies. * **Process Control:** Segregating instrumentation and control cabinets. Installation is straightforward, leveraging the established mounting system of the ProLine G2 enclosure. The panel's dimensions of 1000mm x 800mm are designed to fit specific enclosure configurations, ensuring a precise and secure fit. nVent is a globally recognized leader in electrical enclosure solutions, known for its commitment to quality, innovation, and robust product design. Choosing the ProLine G2 Internal Barrier Panel means investing in a reliable and high-performance solution engineered to meet the rigorous demands of modern industrial infrastructure. Its strategic use can significantly enhance the safety, efficiency, and maintainability of your critical equipment installations.
  • Barrier and extender panels are 16 gauge (1.5 mm), while mounting brackets are 14 gauge (1.75 mm)
  • RAL 7035 polyester powder paint, textured light gray
  • All mounting hardware included
  • Durable steel construction for industrial environments
  • Light gray finish for seamless integration

Specifications

Application
Controls and Drives; Power Distribution
Cable Entry
No
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1000 x 800 mm
Insulation
No
Material
Mild Steel
Material
Steel
Mounting Type
Horizontal Mount
Product Family
ProLine
Series
ProLine G2
Size
1000x800
Thickness
1.52 mm
Thickness
16 ga
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
48.5 lb
Package Dimensions (L x W x H)
46 IN x 31 IN x 1.88 IN
Package Dimensions (L x W x H)
116.84 cm x 78.74 cm x 4.7752 cm
Package Weight (Imperial)
48.500 L
Package Weight (Metric)
22.000 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2AIBP108 Controller

This guide provides step-by-step instructions for installing and configuring the P2AIBP108 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2AIBP108 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the appropriate terminals on the controller. Refer to the wiring diagram for correct terminal assignments.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure proper power supply. Confirm that all connections are secure and correctly wired.

  4. Configure the controller

    Power on the controller and access the configuration interface. Set the necessary parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Adjust settings as needed based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.