nVent P2AFMKE - External Frame Floor Mounting Bracket Kit, Steel, Galvanized
nVent

P2AFMKE

UPC: 783510369026


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent P2AFMKE External Frame Floor Mounting Kit (SKU: P2AFMKE) provides a secure, field-installable method for mounting PROLINE G2 enclosures to the floor. Constructed from 14-gauge galvanized steel, these brackets offer corrosion resistance suitable for industrial environments. The kit includes two external mounting brackets and sealing washers to maintain Type 4 or 12 enclosure ratings after installation. Designed to fit all PROLINE G2 frame sizes, this kit simplifies installation by mounting between the enclosure base and securing bolts, extending beyond the enclosure edge for a stable anchor. Installation requires no specialized tools or backside access, accelerating deployment. Typical applications include industrial control panels, automation enclosures, and electrical housing in manufacturing, data centers, and utility facilities. This mounting solution ensures compliance with UL/CSA external mounting requirements. For additional fastener needs, consider nVent P2ABVM6FP.
  • The brackets are constructed from 12-gauge (2.5 mm) galvanized steel.
  • Mount between the base and the base securing bolts, and extend just beyond the edge of the enclosure
  • Compatible with all ProLine enclosures with either a solid, 0-mm base or gland plate
  • Compatible with all PROLINE G2 frame sizes.
  • Facilitates secure floor mounting without requiring backside access.

Specifications

Application
Power Distribution; Controls and Drives
Color
Unpainted
Finish
Galvanized
Ip Rating
Type 4 or 12
Material
Galvanized Steel
Material
Mild Steel
Material
Steel, Galvanized
Mounting Type
Floor Mounting
Mounting Type
Floor Mounting Bracket
Nema Rating
Type 4 or 12
Product Family
ProLine
Series
ProLine G2
Thickness
12 ga
Thickness
2.66 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
1.34 lb
Package Dimensions (L x W x H)
5.53 IN x 5.53 IN x 4.94 IN
Package Dimensions (L x W x H)
14.0462 cm x 14.0462 cm x 12.5476 cm
Package Weight (Imperial)
1.340 L
Package Weight (Metric)
0.608 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2AFMKE Controller

This guide provides step-by-step instructions for installing and configuring the P2AFMKE Controller for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2AFMKE controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure the connections are tight and secure to prevent any electrical issues.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is outside the specified range, recheck your connections.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters as per your application requirements. Save the settings once completed.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.