
nVent NHZ360646G460 SpectraCool Narrow Hazardous Location AC with RAC, 6000BTU 460V, Brushed, SS316
UPC: 783510293864
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Engineered for Class I, Division 2 hazardous locations
- Brushed SS316 stainless steel enclosure for superior corrosion resistance
- Type 4X rating for protection against water and dust ingress
- 6000 BTU cooling capacity with 460V operation
- No purge or pressurized system required for simplified installation
- Cleanable, reusable aluminum mesh filter protects coils for extremely dusty and dirty atmospheres
- Digital temperature control
- Narrow design to accommodate 12-in (300-mm) deep cabinets
- R134a, R513A or R407C earth-friendly Refrigerant
- Models for 115, 230 and 400/460 3-phase VAC power input
Specifications
Application | Hazardous Environments |
Color | Unpainted |
Color | Brushed |
Depth | 14 in |
Depth | 356 mm |
Finish | Brushed |
Height | 36 in |
Height | 914 mm |
Material | SS316 |
Material | SS316 Stainless Steel |
Material | Stainless Steel 316L |
Max Current | 1.8 A |
Nema Rating | Type 4X |
Nominal Capacity Btu/h | 6,000 Btu/h |
Nominal Capacity Watts | 1,757 W |
Nominal Voltage | 460 V |
Number Of Phases | 1 |
Operating Temperature | -40-131 |
Operating Temperature | -40-55 |
Product Family | SpectraCool |
Remote Access Control | Yes |
Series | SpectraCool Narrow Hazardous Location AC |
Size | 6000BTU |
Thickness | 1.27 mm |
Thickness | 18 ga |
Type | Air Conditioners |
Voltage AC | 400-460 V |
Voltage Rating | 460 V |
Voltage Rating | 460 VAC |
Weight | 47 kg |
Weight | 100 lb |
Width | 11.5 in |
Width | 292 mm |
Package Dimensions (L x W x H) | 37 IN x 18 IN x 14 IN |
Package Dimensions (L x W x H) | 93.98 cm x 45.72 cm x 35.56 cm |
Package Weight (Imperial) | 100.000 L |
Package Weight (Metric) | 45.360 kg |

T430646G404
The nVent T430646G404 industrial cable gland is a robust, UL-listed solution engineered for secure cable entry in demanding industrial environments. Designed for use in hazardous locations, this cable gland ensures reliable sealing against moisture, dust, and mechanical stress while maintaining electrical integrity. Manufactured by nVent, a global leader in electrical and thermal management solutions, the T430646G404 meets stringent industry standards for performance and durability. This cable gland is ideal for applications requiring ingress protection (IP66/IP68) and resistance to extreme temperatures, chemicals, and vibrations. Commonly deployed in oil and gas, chemical processing, mining, and manufacturing facilities, the T430646G404 provides a dependable barrier against environmental contaminants while facilitating safe cable routing. Its corrosion-resistant materials and flame-retardant properties make it suitable for both indoor and outdoor installations, including those in classified hazardous areas. Key features of the nVent T430646G404 include a one-piece construction for simplified installation, a wide cable diameter range for versatility, and a secure locking mechanism to prevent accidental disconnection. The gland’s design accommodates both armored and unarmored cables, ensuring compatibility with a broad spectrum of industrial wiring systems. Professionals appreciate its tool-free installation in many configurations, reducing labor time and minimizing the risk of installation errors. Installation considerations for the T430646G404 include proper cable sizing to ensure a tight seal, adherence to local electrical codes, and compatibility checks with junction boxes or enclosures. nVent provides comprehensive installation guidelines and technical support to ensure optimal performance. The gland’s compliance with UL 514B and other international standards underscores its reliability in critical applications where downtime cannot be tolerated. Choosing nVent for cable gland solutions means selecting a manufacturer with over a century of expertise in electrical protection. nVent’s commitment to innovation and quality ensures that products like the T430646G404 deliver long-term performance, reducing maintenance costs and enhancing system safety. Whether for new construction or retrofitting existing systems, the T430646G404 stands as a trusted choice for professionals who demand uncompromising quality in cable management.
CR430816G073
The nVent CR430816G073 is a high-performance industrial component designed for demanding environments. Engineered for durability and efficiency, this product ensures reliable operation in critical applications. With precision manufacturing and robust construction, it meets stringent industry standards. Ideal for industrial settings requiring consistent performance, the nVent CR430816G073 delivers dependability and longevity. Trusted by professionals, this component is a key solution for enhancing operational efficiency and reducing downtime.How to Install the NHZ360646G460 Air Conditioner
This guide provides step-by-step instructions for installing the NHZ360646G460 air conditioner in a suitable enclosure.
Estimated time: 1h
Tools needed:
Screwdriver, Wrench, Ratchet driver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Mounting gasket kit, Electrical wire, Fuses or HACR circuit breaker
- Inspect the air conditioner
Check for any visible damage and verify functionality before proceeding with the installation.
- Prepare the installation site
Ensure a six-inch clearance on at least one side and twenty inches in front of the unit for maintenance access.
- Mount the air conditioner
Using the mounting gasket kit, secure the air conditioner to the enclosure, ensuring it is level and within 3° from vertical.
- Wire the air conditioner
Connect the unit to a properly grounded power supply according to the nameplate specifications, using copper conductors only.
- Adjust the controller settings
Set the desired cabinet temperature on the controller, following the instructions for displaying and changing program settings.
- Test the air conditioner
Energize the unit and verify that the evaporator blower and compressor operate correctly for at least five minutes.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.



