nVent N360826G802 SpectraCool Narrow Advanced Corrosion Protection Lvl 2, 8000BTU 230V, Brushed, SS316
UPC: 783510357726
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Narrow design accommodates 12-inch (300-mm) deep cabinets
- Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
- Attractive industrial design with minimal use of visible fasteners
- Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing) side and an additional wrap around the thermostat
- Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance
- Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series)
- Reliable mechanical thermostat on enclosure side of the unit; indoor air conditioner models include digital display on ambient side
- Energy efficient rotary compressor on N36 and N43 models
- Dust-resistant condenser coil allows the unit to be run filterless in most applications
- Galvanized sheet-metal cover for rugged factory and outdoor environments
Specifications
Application | Corrosive Environments; Controls and Drives; Power Distribution |
Application | Controls and Drives;Corrosive Environments;Power Distribution |
Color | Unpainted |
Corrosion Resistant | Yes |
Depth | 356 mm |
Depth | 14 in |
Finish | Brushed #4 |
Height | 36 in |
Height | 914 in |
Height | 36 mm |
Height | 914 mm |
Material | Stainless Steel 316L |
Max Current | 6.1 A |
Mechanical Advantage | Galvanized sheet metal standard |
NEMA Rating | 4X Watertight, corrosion-resistant |
Nominal Capacity Btu/h | 8,500 Btu/h |
Nominal Capacity Watts | 2,635 W |
Nominal Voltage | 230 V |
Number Of Phases | 1 |
Operating Temperature | -40-52 °C |
Operating Temperature | -40-55 |
Operating Temperature | -40-55 °C |
Operating Temperature | -40-125 °F |
Outdoor Installation | Yes |
Product Family | SpectraCool |
Protection Rating | NEMA Type 4X |
Refrigerant | R513A |
Remote Access Control | No |
Thickness | 51.40mm (2.024") |
Thickness | 1.21 mm |
Thickness | 18 ga |
Type | Air Conditioners |
Voltage AC | 200-250 V |
Weight | 48 kg |
Weight | 114 lb |
Width | 292 mm |
Width | 11.5 in |
Package Dimensions (L x W x H) | 36.01 IN x 14 IN x 11.5 IN |
Package Dimensions (L x W x H) | 91.4654 cm x 35.56 cm x 29.21 cm |
Package Weight (Imperial) | 114.000 L |
Package Weight (Metric) | 51.710 kg |
How to Install the N360826G802 Air Conditioner
Installation guide for mounting and wiring the N360826G802 air conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting gasket kit, Copper conductors, Slow blow fuse or HACR circuit breaker
- Inspect and Test Functionality
Inspect the air conditioner for any damage. Test its functionality before mounting. Ensure the unit has been in an upright position for at least 5 minutes if it was transported horizontally. Refer to the nameplate for electrical requirements and wire to a properly grounded power supply using only copper conductors. The minimum circuit ampacity should be at least 125% of the amperage shown on the unit nameplate. Do not connect other equipment to this circuit. Immediately after applying power, the evaporator blower should start. Operate the unit with the compressor running for 5-10 minutes by setting the cooling thermostat or controller setpoint below the ambient temperature. Condenser air temperatures should become warmer than room temperatures within a few minutes after the condenser impellers start.
- Mount the Air Conditioner
Install the provided mounting gasket kit to the air conditioner. Mount the air conditioner onto the enclosure, taking care not to damage the gasket. Avoid dragging the unit on the enclosure with the gasket attached to maintain a watertight seal. Ensure the unit remains upright during operation.
- Wire the Unit
Refer to the nameplate for specific electrical requirements. Wire the unit to a properly grounded power supply using copper conductors. The electrical circuit should be fused with a slow blow fuse or an HACR circuit breaker. For units requiring a remote thermostat, wire the thermostat outputs to the appropriate terminals on the 24 VAC terminal strip according to the correct wiring diagram.
- Set Thermostat
Set the thermostat for the required cabinet temperature. Refer to the 'Sequence of Operation' section for thermostat adjustment and operation details. For testing purposes only, the thermostat stop screw may be removed to allow settings below 70 F, but it must be replaced and verified afterward.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.