nVent N360816G800 SpectraCool Narrow Advanced Corrosion Protection Lvl 2, 8000BTU 115V, Lt Gray, Steel
UPC: 783510357658
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Narrow design accommodates 12-inch (300-mm) deep cabinets
- Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
- Attractive industrial design with minimal use of visible fasteners
- Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing) side and an additional wrap around the thermostat
- Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance
- Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series)
- Reliable mechanical thermostat on enclosure side of the unit; indoor air conditioner models include digital display on ambient side
- Energy efficient rotary compressor on N36 and N43 models
- Dust-resistant condenser coil allows the unit to be run filterless in most applications
- Galvanized sheet-metal cover for rugged factory and outdoor environments
Specifications
Amperage Rating | 9.9/11.6 A |
Application | Controls and Drives; Power Distribution; Corrosive Environments |
Application | Controls and Drives;Corrosive Environments;Power Distribution |
Btu Rating | 7,800 |
Color | Gray |
Color | Lt Gray |
Color | Light Gray |
Color Code | RAL 7035 |
Corrosion Resistant | Yes |
Depth | 14 in |
Depth | 356 mm |
Finish | Powder Coated |
Frequency | 60 Hz |
Frequency Rating | 50/60 Hz |
Frequency Rating, Maximum | 60 Hz |
Frequency Rating, Minimum | 50 Hz |
Height | 914 mm |
Height | 36 in |
Material | Mild Steel |
Material | Steel |
Max Current | 11.6 A |
Mechanical Advantage | Galvanized sheet metal standard |
Mounting Type | Panel Mount |
NEMA Rating | 4X Watertight, corrosion-resistant |
Nema Rating | NEMA 4X |
Nominal Capacity Btu/h | 7,800 Btu/h |
Nominal Capacity Watts | 2,286 W |
Nominal Voltage | 115 V |
Number Of Phases | 1 |
Operating Temperature | -40-52 °C |
Operating Temperature | -40-55 °C |
Operating Temperature | -40-125 °F |
Operating Temperature | -40-55 |
Outdoor Installation | Yes |
Poles | 1P |
Power | 1100/1333 W |
Product Family | SpectraCool |
Protection Rating | NEMA Type 4X |
Refrigerant | R513A |
Remote Access Control | No |
Series | SpectraCool Narrow |
Size | Narrow |
Thickness | 1.21 mm |
Thickness | 18 ga |
Thickness | 51.40mm (2.024") |
Type | Air Conditioners |
Voltage AC | 100-120 V |
Voltage Rating | 115 V |
Weight | 114 lb |
Width | 292 mm |
Width | 11.5 in |
Package Dimensions (L x W x H) | 36.01 IN x 14 IN x 11.5 IN |
Package Dimensions (L x W x H) | 91.4654 cm x 35.56 cm x 29.21 cm |
Package Weight (Imperial) | 114.000 L |
Package Weight (Metric) | 51.710 kg |
Frequently Asked Questions
What is the cooling capacity of this unit?
The unit has a nominal capacity of 7800 Btu/h, which is equivalent to 2286 Watts.
What type of refrigerant does this unit use?
This unit uses R513A refrigerant.
What is the nominal voltage for this air conditioner?
The nominal voltage for this unit is 115V.
What is the weight of the SpectraCool Narrow air conditioner?
The air conditioner weighs 114lb.
What are the dimensions of the SpectraCool Narrow air conditioner?
The air conditioner has a height of 36 inches, a width of 11.5 inches, and a depth of 14 inches.
What is the operating temperature range for outdoor installation?
The outdoor operating temperature range is from -40 F/-40 C to 131 F/55 C.
What NEMA protection ratings does this unit have?
The unit has NEMA Type 12, 3R, and 4X (optional) protection ratings.
Does this unit have Remote Access Control (RAC) capabilities?
No, this specific model does not come with Remote Access Control (RAC).
What is included in the Advanced Corrosion Protection Level 2 (ACP L2)?
ACP L2 includes protective coatings on copper tubing, coils, thermostat, and an additional wrap around the thermostat.
What material is the cover of the air conditioner made from?
The cover is made of galvanized sheet-metal for rugged environments.
How to Install the N360816G800 Air Conditioner
Installation guide for mounting and wiring the N360816G800 air conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting gasket kit, Copper conductors, Mounting screws
- Inspect and Test Functionality
Inspect the air conditioner for any damage that may have occurred during shipment. If the unit has been in a horizontal position, ensure it is upright for at least 5 minutes before operation. Test the unit's functionality before mounting it to the enclosure. Refer to the nameplate for electrical requirements and wire to a properly grounded power supply using copper conductors. Ensure the minimum circuit ampacity is at least 125% of the unit's nameplate amperage. Immediately after applying power, the evaporator blower should start. Operate the unit with the compressor running for 5-10 minutes by setting the cooling thermostat or controller setpoint below the ambient temperature. Condenser air temperatures should become warmer than room temperature within a few minutes after the condenser impellers start.
- Mount the Air Conditioner
Install the mounting gasket kit to the air conditioner. Mount the air conditioner onto the enclosure, taking care not to damage the mounting gasket. Avoid dragging the unit on the enclosure with the gasket attached to maintain a watertight seal. Ensure the unit remains upright during operation.
- Wire the Unit
Refer to the nameplate for electrical requirements. Wire the unit to a properly grounded power supply using copper conductors. The electrical circuit should be fused with a slow-blow fuse or an HACR circuit breaker. If your unit requires a remote-mounted thermostat, wire its outputs to the appropriate terminals on the 24 VAC terminal strip according to the correct wiring diagram. For units with a phase monitor (N360X46GXXX only), verify correct phasing and voltage before operating. If the phase monitor light is not illuminated, disconnect power and swap any two power leads at the terminal block.
- Set Thermostat
Set the thermostat for the required cabinet temperature. Refer to the 'Sequence of Operation' section for thermostat adjustment and operation details. Note: For testing purposes, the thermostat stop screw may be removed on equipped units to allow settings below 70 F. After testing, replace the stop screw and verify the thermostat cannot be set below 70 F to prevent coil freeze-ups.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.